Installation Guide for Altronix models including: Trove2HN2, THN2, Trove2HN2 Honeywell NetAXS Backplane, Trove2HN2, Honeywell NetAXS Backplane, NetAXS Backplane, Backplane

IITrove HN I27U

Click to View

Altronix THN2 | Outdoor Enclosure Backplane, Honeywell NetAX

Trove2HN2 THN2 Installation Guide


File Info : application/pdf, 8 Pages, 874.54KB

PDF preview unavailable. Download the PDF instead.

Trove HN
Access & Power Integration

SIGNALING

Trove2HN2
- Trove2 enclosure with Altronix/Honeywell NetAXS backplane (THN2)
THN2
- Altronix/Honeywell NetAXS backplane only

Installation Guide

All registered trademarks are property of their respective owners.

More than just power.TM

Rev. THN052518 Installing Company: _________________________ Service Rep. Name: __________________________________________

Address: _________________________________________________________ Phone #: _________________________

Overview: Trove2HN2 accommodates various combinations of Honeywell NetAXS boards with or without Altronix power supplies and accessories for access systems.

Specifications: Trove2HN2 Trove2 enclosure with THN2 Altronix/Honeywell backplane. · Includes: tamper switch, cam lock, mounting hardware. · 16 Gauge enclosure with ample knockouts for convenient access.
Enclosure Dimensions (H x W x D): 27.25" x 21.75" x 6.5" (692.2mm x 552.5mm x 165.1mm). Accommodates up to four (4) 12VDC/7AH batteries.
THN2 THN2 Altronix/Honeywell backplane. · 16 Gauge backplane. · Includes mounting hardware.
Dimensions (H x W x D): 25.375" x 19.375" x 0.3125" (644.6mm x 492.1mm x 7.9mm). THN2 accommodates a combination of the following: Altronix: · Up to four (4) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or eFlow104NB. · Up to four (4) ACM8(CB) or ACM8S(CB). · Up to three (2) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), or VR6. Honeywell: · Up to four (4) NX4PCB access control panels. · Up to eight (8) NetAXS-123 access control panels. · Up to eight (8) NXD1 or NXD2 add-on boards. · Up to four (4) NX4IN or NX4OUT boards.

Agency Listings: · UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
*Stand-by Power Level I if no battery is supplied. · This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada. · CE European Conformity.

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having juris-

diction. Product is intended for indoor use only.

1. Remove backplane from enclosure. Do not discard hardware.

2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws

in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the three upper screws; level and secure.

Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install

the three fasteners. Place the enclosure's upper keyholes over the three upper screws.

Install the three lower screws and make sure to tighten all screws.

3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent)

Fig. 1

in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the

enclosure approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch

wiring to the Access Control Panel input or the appropriate UL Listed reporting device.

Enclosure

To activate alarm signal open the door of the enclosure. 4. Mount Altronix/Honeywell boards to backplane, refer to pages 3-6.

Edge of Enclosure

Tamper Switch (included)

To Access Control Panel or UL Listed Reporting Device

- 2 -

Trove2HN2 / THN2 Installation Guide

Installation Instructions for Altronix Power Supplies and Sub-Assemblies to THN2: 1. Fasten spacers (provided) into pem configuration (A) or (B) of backplane (Fig. 2, pg. 3). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 2a, pg. 3). 3. Mount backplane to enclosure with hardware.

Fig. 2a

Access Controller Position Chart for the Following Models:

Altronix Board

Pem Mounting

Altronix Power Supply/Charger or Sub-Assembly

A

Altronix Sub-Assembly

B

Fig. 2

Pem Spacer

Pan Head Screw

Altronix

Backplane

Power Supply or

Sub-Assembly

A

Metal Spacer Placement

B

A

Metal Spacer Placement

B

A

Metal Spacer Placement

B

A

Metal Spacer Placement

Trove2HN2 / THN2 Installation Guide

- 3 -

Installation Instructions for Honeywell NX4PCB to THN2: 1. Fasten spacers (provided) to appropriate pems on backplane (Fig. 3, pg. 4). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 3a, pg. 4).
Note: Honeywell NX4PCB modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 3 below. 3. Mount backplane to enclosure with hardware.
Fig. 3

Fig. 3a

Pem Spacer

Honeywell Pan Head Access Controller Screw

Backplane

RJ45 Jack

RJ45 Jack

NX4PCB

NX4PCB

RJ45 Jack
NX4PCB

RJ45 Jack
NX4PCB

- 4 -

Trove2HN2 / THN2 Installation Guide

Installation Instructions for Honeywell NetAXS-123 with/without NXD1/NXD2 to THN2:

1. Fasten spacers (provided) to appropriate pems on backplane (Fig. 4, pg. 5). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 4a, pg. 5).

Fig. 4a

Note: Honeywell NetAXS-123 modules have one (1) RJ45 jack each.

Please make sure that they are mounted correctly, as shown in Fig. 4 below.

In order to properly mount and connect NXD1/NXD2 do the following:

Pem

- prior to mounting on backplane, attach NXD1/NXD2 to the NetAXS-123

Spacer

by connecting the multi-pin connector on the bottom of NXD1/NXD2 to the

multi-pin jack on NetAXS-123. Make sure that pre-installed bump screws on NXD1/NXD2 go through the corresponding holes in NetAXS-123. - secure NXD1/NXD2 to NetAXS-123 using pre-installed bump screws

Honeywell Pan Head Access Controller Screw

Backplane

and included spacers (Fig. 4b, pg. 5).

- after NXD1/NXD2 is firmly attached and connected to NetAXS-123, follow steps 1 and 2 above to mount them onto THN2.
3. Mount backplane to enclosure with hardware.

Bottom of NXD1/NXD2

Fig. 4b

Fig. 4

Mounting Hole

RJ45 Jack

RJ45 Jack

Spacer

Pre-installed Bump Screw

NXD1 or NXD2

NXD1 or NXD2

Bottom of NetAXS-123

NetAXS-123

NetAXS-123

RJ45 Jack

RJ45 Jack

NXD1 or NXD2 NetAXS-123
RJ45 Jack
NXD1 or NXD2 NetAXS-123
RJ45 Jack

NXD1 or NXD2 NetAXS-123
RJ45 Jack
NXD1 or NXD2 NetAXS-123
RJ45 Jack

NXD1 or NXD2

NXD1 or NXD2

NetAXS-123

NetAXS-123

Trove2HN2 / THN2 Installation Guide

- 5 -

Installation Instructions for Honeywell NX4IN or NX4OUT to THN2: 1. Fasten spacers (provided) to appropriate pems on backplane (Fig. 5, pg. 6). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 5a, pg. 6). 3. Mount backplane to enclosure with hardware.

Fig. 5a

Fig. 5

Pem Spacer

Honeywell Pan Head Access Controller Screw

Backplane

NX4IN or NX4OUT

NX4IN or NX4OUT NX4IN or NX4OUT

NX4IN or NX4OUT

- 6 -

Trove2HN2 / THN2 Installation Guide

0.45" (11.4mm)

THN2 Dimensions (H x W x D): 25.375" x 19.375" x 0.3125" (644.6mm x 492.1mm x 7.9mm)

2.2" (55.9mm)

19.375" (492.1mm)

2.2" (55.9mm)

0.156" ( 3.96mm)

25.375" (644.6mm)

8.5" (215.9mm) 12.625" (320.7mm) 16.25" (412.8mm)

0.45" (11.4mm)

1.0" (25.4mm)
7.5" (190.5mm) 9.2" (233.7mm)

1.0" (25.4mm) 7.5" (190.5mm) 9.2" (233.7mm)

Trove2HN2 / THN2 Installation Guide

- 7 -

Trove2HN2 Enclosure Dimensions (H x W x D approximate): 27.25" x 21.75" x 6.5" (692.2mm x 552.5mm x 165.1mm)

2.00" (50.8mm)

21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm)

2.00" (50.8mm)

6.25" (158.8mm)

1.25" (31.8mm)

6.25" (158.8mm) 1.25" (31.8mm)

1.5" (38.1mm)

0.5625" (14.3mm)

0.685" (17.4mm)

1.77" (45mm)

Knockouts 1.125" (28.3mm)

2.415" (61.3mm) 0.885" (22.5mm)

19.80" (502.9mm)

2.00" (50.8mm)

6.75" (171.5mm)

8.25" (209.5mm)

27" (685.8mm)

8.00" (203.2mm)

1.00" (25.4mm)

0.85" (21.6mm)

1.25" (31.8mm)

2.00" (50.8mm)

2.00" (50.8mm)

5.25" (133.4mm)

7.00" (177.8mm)

5.25" (133.4mm)

1.25" (31.8mm) 2.00" (50.8mm)

Altronix is not responsible for any typographical errors. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

web site: www.altronix.com | e-mail: info@altronix.com

IITrove2HN2 / THN2

I27U

MEMBER

- 8 -

Trove2HN2 / THN2 Installation Guide



References

Adobe PDF Library 16.0.3 Adobe InDesign 17.0 (Macintosh)