User Manual for REIGN models including: TX-100, RE-100, Remote Transmitter, Transmitter, TX-100

REIGN-TX-100-Manual-4-1-2019

Reign Receiver & Transmitter Kit Manual

Reign Long Range Transmitter & Receiver Kit | All Security Equipment

PDF preview unavailable. Download the PDF instead.

Transmitter-Solutions-TX-100-Manual ?v=1638890404"
T X ­ 1 0 0 ­ nc & X R E ­ 1 0 0 TRANSMITTER & RECEIVER KIT
v.7.27.21
REIGN wireless technology
The Reign TX-100-NC & XRE-100 transmitter/receiver kit is a revolutionary product. This product allows for wirelessly triggering
a relay through a battery powered hand held transmitter with extreme range, no line-of-sight wireless technology.
WHAT'S INCLUDED
There are two pieces included in the TX-100-NC to XRE-100 kit. The Reign TX-100-NC to XRE-100 kit includes (1) TX-100-NC (transmitter) and (1) XRE-100 (receiver units).
HOW IT WORKS...
Congratulations on your purchase of the Transmitter Solutions TX-100-NC to XRE-100 - Transmitter/Receiver kit. It has been designed with state-of-the-art radio technology to provide maximum transmission through obstruction and interference. The TX-100-NC to XRE-100 kit can be easily paired together with the program/learn button on the XRE-100 board. Simply connect the Dry output closure to the device you are triggering and you will be up and running. The TX-100-NC is a send/receiver unit that sends a signal when the button is pressed, indicated by a red LED light. And receives a signal back, indicated by a green LED light. This allows users to know the signal was sent and received by the corresponding XRE-100 unit.
IMPORTANT - When using XRE to TX-100-NC, Mode Dipswitch 2 ON

CONTENTS:
1.

..............................................................

. RECEIVER SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

. TRANSMITTER SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

. POWER DETAILS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

. LED INDICATORS.........................................................................................6

. RELAY DIAGRAM AND WIRING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

. DIP SWITCHES..............................................................................................8

. BATTERY BACKUP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

. PAIRING IN THE FIELD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

. TROUBLESHOOTING....................................................................................10

2

1.
CC
*.1035"/5
N CC

CC C

C C
'$$3BEJBUJPO&YQPTVSF4UBUFNFOU CC

-

TX-100-NC while in use must have

visor mount or wall mount,

-

'$$$BVUJPO
-
. RECEIVER SPECIFICATIONS
Power Input: 12-24 Volt AC/DC
Relays: 10A 250 VAC/ 28VDC
12V: 50mA (idle) 1A (transmit) 24V: 25mA (idle) 500ma (transmit) Range: 1/2 mile (Through obstructions) Relays: 10A 250 VAC/ 28VDC Minimum / Maximum Temperature Range: -40°F to 185°F (-40°C to 85°C) Security Encryption: AES POWER INPUT: 12 to 24 VOLTS AC/DC. - 1 AMP Minimum Always follow polarity when DC Power is used.

, such as vehicle

BATTERY INPUT: for 12 Volt Sealed Lead Acid (SLA) battery only.
Solid GREEN LED indicates battery charging. Momentarily flashing GREEN LED indicates battery is charged and a trickle/conditioning charge is occurring.
3

. TRANSMITTER SPECIFICATIONS
Minimum / Maximum Temperature Range: -40°F to 185°F (-40°C to 85°C) Security Encryption: AES Range: 1/2 mile (Through obstructions) Power: 9V Lithiom Battery

3-1/2"

12

2-3/8"
1 MODE DIP SWITCHES
SWITCH 1 ­ Learn Mode SWITCH 2 ­ Not used SWITCH 3 ­ Not used
2 TRANSMIT LEVEL
Clockwise for more power when transmitting. Counterclock wise for less power when transmitting. (Battery life will vary based on transmit power level set)
4

. POWER DETAILS
The XRE-100 requires 1 amp of current draw to transmit at full power.
IMPORTANT - XRE REQUIRES AT LEAST 1AMP POWER SUPPLY

1

2

1 POWER INPUT:
Power Input: 12 to 24 VOLTS AC/DC. Always follow polarity when DC Power is used. 1 AMP Minimum
2 BATTERY INPUT:
Battery Input: for 12 Volt Sealed Lead Acid (SLA) battery only. Solid Green LED = Battery charging Momentary Flashing LED = Battery is fully charged and a trickle/conditioning charge is occurring

5

. LED INDICATORS
STATUS LEDs:
1 RECEIVE - flashes GREEN momentarily when a valid radio transmission is received. 2 TRANSMIT - flashes RED momentarily when the unit transmits a packet as a result of an Relay Input change
event or handshake.
3 STATUS/ PROG - flashes yellow patterns indicating status of the unit: pairing, error, etc. 4 RUN - flashes ORANGE 1 second ON and 1 second OFF indicating the microprocessor is running. 5 POWER LED - Glows solid orange when power is present. 5 volt relay supply, 3.3 volt logic supply, and VPA
3.6 volt power amplifier supply.
1 2
3 4
5
­
6

. RELAY DIAGRAM AND WIRING
1 RELAY OUTPUTS
Relay Outputs - The Reign XRE-100 comes with 2-relay outputs. Relay 1 is the relay specified for use when the TX-100-NC is triggered. Relay 2 is used as a delay relay set for a certain amount of time to trigger after relay 1 is activated. Please refer to DIP switch 6 setting on page 8 for more information. The relay state is indicated by the Green ACTIVE LED above the relay.
1
7

DIP SWITCHES

1 MODE SWITCHES
SWITCH 1 ­ PROG (PAIR) ­ Use for programming TX-100-NC to XRE-100 SWITCH 2 ­ Not used SWITCH 3 ­ Not used SWITCH 4 ­ Not used

The behavior of the relay(s) is controlled by Dipswitch 5 & 6.

SWITCH 5 = momentary or latching SWITCH 6 = single or dual relays

DIPSWITCH 5 DIPSWITCH 6 FUNCTION

OFF

OFF

ON OFF

OFF ON

OFF

OFF

2 PROGRAM/TEST BUTTON:
To program turn DIP switch 1 to the on position in both the XRE-100 and TX-100-NC. With both DIP switches turned on press the TX-100-NC transmit button.
If done correctly the XRE-100 will flash yellow status LED 3 times and TX-100 will flash green LED 3 times.
3 RELAY DELAY POTENTIOMETER:
Full counter clockwise is 1/2 second delay from relay 1 to relay 2 activation. Full clockwise is 10 second delay from relay 1 activation to relay 2 activation. To activate make sure DIP switch 6 is set to ON in the XRE-100.

8

2 1
3
. BATTERY BACKUP
12 Volt Sealed Lead Acid (SLA) battery only. Solid GREEN LED indicates battery charging. Momentarily flashing GREEN LED indicates battery is charged and a trickle/conditioning charge is occurring.
. PAIRING UNIT IN THE FIELD
To program turn DIP switch 1 to the on position in both the XRE-100 and TX-100-NC. With both DIP switches turned on press the TX-100-NC transmit button. If done correctly the XRE-100 will flash yellow status LED 3 times and TX-100-NC will flash green LED 3 times.
9

. TROUBLESHOOTING

TX-100-NC & XRE-100 units are not communicating: 1 - Check the Run LED on the XRE-100-NC. Normal operation will be orange LED flashing once a second. 2 - Press the button on the TX-100-NC. When pressed, the TX-100-NC will send a radio test packet and the RED TRANSMIT LED will illuminate. If the paired XRE-100 is online, it will acknowledge with a radio test packet ­ indicated by a momen-tary on the green receive LED.

If you do not see the transmit and receive LED lights activate: 1 - Power cycle the XRE unit. 2 - Move the XRE-100 unit to a higher location and avoid mounting on/in metal objects

XRE LED GUIDE

If you are not getting the desired range between the TX-100 and XRE-100 unit:
1 - Ensure the XRE-100 has at least 1-amp of power dedicated to itself. 2 - Move the XRE-100 unit to a higher location - and avoiding mounting in/on metal objects 3 - Check that the potentiometer on the TX-100-NC board is turned to full power. (All the way to the left)

10

WARRANTY
The warranty period of this product is 24 months, beginning from the manufacturing date. During this period, if the product does not operate correctly, due to a defective component, the product will be repaired or replaced at the sole discretion of Transmitter Solutions. This warranty does not extend to the product casing which can be damaged by conditions outside of the control of Transmitter Solutions.
EXCEPT AS SET FORTH ABOVE, TRANSMITTER SOLUTIONS MAKES NO WARRANTIES REGARDING THE GOODS, EXPRESS OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS, EXPRESS OR IMPLIED, WITH REGARD TO THE GOODS AND ACCEPTS THEM "AS-IS/WHERE-IS". TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF THE SALE. BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR DAMAGES OF ANY KIND, WHETHER DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING INJURIES TO PERSONS OR PROPERTY, TO BUYER, ITS EMPLOYEES OR AGENTS, AS A RESULT OF THE SALE. BUYER ALSO AGREES TO HOLD TRANSMITTER SOLUTIONS HARMLESS FROM ANY CLAIMS BUYER, OR ANY THIRD PARTY, MAY HAVE AS A RESULT OF BUYER'S USE OR DISPOSAL OF THE GOODS. BUYER HAS READ THIS DISCLAIMER AND AGREES WITH ITS TERMS IN CONSIDERATION OF RECEIVING THE GOODS.
11


Adobe Illustrator CC 23.0 (Macintosh) Adobe PDF library 15.00