User Manual for FLUKE models including: FLUKE, 62 MAX, 62 MAX, Infrared Thermometer

Infrared Thermometer

Infrared Thermometer Safety Information 3 • See emissivity information for actual temperatures. Reflective objects result in lower than actual temperature measurements. These objects pose a burn hazard. • Do not look directly into the laser with optical tools (for example, binoculars, telescopes, microscopes). Optical tools can focus the laser

62 MAX/62 MAX - Exporters India

Infrared Thermometer. Users Manual ... The Fluke 62 MAX and 62 MAX Infrared Thermometers (the Product) can determine the surface temperature by measuring ...


File Info : application/pdf, 21 Pages, 1.43MB

A1qfS43UteL
62 MAX/62 MAX +
Infrared Thermometer
Users Manual
PN 4060712 April 2012 Rev. 1, 11/12 © 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

Table of Contents

Title

Page

Introduction ................................................................................................................. 1 How to Contact Fluke ................................................................................................. 1 Safety Information ...................................................................................................... 2 Maintenance ............................................................................................................... 6
How to Change the Battery .................................................................................... 6 How to Clean the Product ...................................................................................... 6 Specifications ............................................................................................................. 7 Standards and Agency Approval ................................................................................ 9 The Product ................................................................................................................ 10

i

62 MAX/62 MAX + Users Manual
ii

Introduction
The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target's surface. Note that the Japanese models indicate Celsius only.
Warning
Read all safety information before you use the Product.
How to Contact Fluke
To contact Fluke, call one of the following telephone numbers: · Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) · Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) · Canada: 1-800-36-FLUKE (1-800-363-5853) · Europe: +31 402-675-200 · Japan: +81-03-6714-3114 · Singapore: +65-6799-5655 · Anywhere in the world: +1-425-446-5500
1

62 MAX/62 MAX + Users Manual
Or, visit Fluke's website at www.fluke.com.
To register your product, visit http://register.fluke.com.
To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals.
Safety Information
A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test.
Table 1 tells you about symbols used on the Product and in this manual.
Warning
To prevent eye damage and personal injury: · Read all safety Information before you use the Product. · Do not use the Product if it operates incorrectly. · Use the Product only as specified, or the protection supplied by the
Product can be compromised. · Before you use the Product, inspect the case. Do not use the Product if it
appears damaged. Look for cracks or missing plastic.
2

Infrared Thermometer Safety Information
· See emissivity information for actual temperatures. Reflective objects result in lower than actual temperature measurements. These objects pose a burn hazard.
· Do not look directly into the laser with optical tools (for example, binoculars, telescopes, microscopes). Optical tools can focus the laser and be dangerous to the eye.
· Do not look into the laser. Do not point laser directly at persons or animals or indirectly off reflective surfaces.
· Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
· Do not use the Product around explosive gas, vapor, or in damp or wet environments.
· Use the Product only as specified or hazardous laser radiation exposure can occur.
3

62 MAX/62 MAX + Users Manual

Symbol


Table 1. Symbols

Meaning

Symbol

Meaning

Risk of danger. Important information. See Manual.

This product complies with the

WEEE Directive (2002/96/EC)

marking requirements. The

affixed label indicates that you

must not discard this

electrical/electronic product in

domestic household waste.

Product Category: With



reference to the equipment types

in the WEEE Directive Annex I,

this product is classed as

category 9 "Monitoring and

Control Instrumentation" product.

Do not dispose of this product as

unsorted municipal waste. Go to

Fluke's website for recycling

information.

4

Symbol
 

Infrared Thermometer Safety Information

Table 1. Symbols (cont.)

Meaning

Symbol

Meaning

Warning. Laser.



Conforms to European Union directives.

Battery



Conforms to relevant Australian standards.

Conforms to China Metrology Certification

5

62 MAX/62 MAX + Users Manual
Maintenance
Caution
To avoid damage to the Product, do not leave the thermometer on or near objects of high temperature. How to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16. How to Clean the Product Use soap and water on a damp sponge or soft cloth to clean the Product case. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. See Figure 17.
6

Infrared Thermometer Specifications

Specifications
Temperature Range
Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C)
Response Time (95 %) Spectral Response Emissivity Temperature Coefficient

62 MAX

62 MAX +

-30 °C to 500 °C (-22 °F to 932 °F)

-30 °C to 650 °C (-22 °F to 1202 °F)

0 °C: ±1.5 °C or ±1.5 % of reading, whichever is greater
(32 °F: ±3 °F or ±1.5 % of reading, whichever is greater)
 -10 °C to <0 °C: ±2 °C (14 °F to <32 °F: ±4 °F) < -10 °C: ±3 °C (<14 °F: ±6 °F)

0 °C: ±1 °C or ±1 % of reading, whichever is greater (32 °F: ±2 °F or ±1 % of reading, whichever is greater)
 -10 °C to <0 °C: ±2 °C (14 °F to <32 °F: ±4 °F) < -10 °C: ±3 °C (<14 °F: ±6 °F)

<500 ms (95 % of reading) <300 ms (95 % of reading)

8 to 14 microns

0.10 to 1.00

±0.1 °C/°C or ±0.1 %/°C of reading (whichever is greater)

7

62 MAX/62 MAX + Users Manual

Optical Resolution
Display Resolution
Repeatability (% of reading)
Power
Battery Life
Weight Size Operating Temperature Storage Temperature Operating Humidity Operating Altitude Storage Altitude

10:1

12:1

(calculated at 90 % energy) (calculated at 90 % energy)

0.1 °C (0.2 °F)

±0.8 % of reading or ±1.0 °C ±0.5 % of reading or ±0.5 °C (2 °F), whichever is greater (1 °F), whichever is greater

1 AA IEC LR06 Battery

10 hours with laser and backlight on

8 hours with laser and backlight on

255 g (8.99 oz)

(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches

0 °C to 50 °C (32 °F to 122 °F)

-20 °C to 60 °C (-4 °F to 140 °F), (without battery)

10 % to 90 % RH non-condensing @ 30 °C (86 °F)

2000 meters above mean sea level

12,000 meters above mean sea level

8

Infrared Thermometer Standards and Agency Approval

Ingress Protection Rating Drop Test Vibration and Shock EMC

IP 54 per IEC 60529 3 meters IEC 60068-2-6 2.5 g, 10 to 200 Hz, IEC 60068-2-27, 50 g, 11 ms EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval
Compliance ............................................. EN/IEC 61010-1 Laser Safety ............................................ EN 60825-1 Class 2 Implement Standard ............................... Q/SXAV37

9

62 MAX/62 MAX + Users Manual

The Product

1

2

gtt01.eps
10

Infrared Thermometer The Product

3

4

/

5

5

6

Max/Min/Avg/Diff

gtt14.eps
11

62 MAX/62 MAX + Users Manual
7

+

=

10 min
OFF
gtt16.eps
12

Infrared Thermometer The Product

8

9

10
0ºC 32ºF

30 Min
12

9

3

6

11
22ºC 72ºF

125°F

gtt15.eps
13

62 MAX/62 MAX + Users Manual
12
38 mm @ 60 mm @ 100 mm @ 300 mm 600 mm 900 mm

13
33 mm @ 50 mm @ 85 mm @ 300 mm 600 mm 900 mm

S

1.5" @ 2.4" @ 4" @

12"

24"

36"

D

62 MAX D:S = 10:1

S

1.4" @ 2" @

12"

24"

D

62 MAX + D:S = 12:1

3.4" @ 36"

gtt08-11.eps
14

Infrared Thermometer The Product
14

70 21

gtt03.eps
15

62 MAX/62 MAX + Users Manual
15

75°
225° 75°

gtt04.eps
16

16
+

Infrared Thermometer The Product
17

gtt13.eps
17

62 MAX/62 MAX + Users Manual
18



References

3-Heights(TM) PDF Security Shell 4.8.25.2 (http://www -tools.com)