User Manual for FLUKE models including: FLUKE, 62 MAX, 62 MAX, Infrared Thermometer
Infrared Thermometer Safety Information 3 • See emissivity information for actual temperatures. Reflective objects result in lower than actual temperature measurements. These objects pose a burn hazard. • Do not look directly into the laser with optical tools (for example, binoculars, telescopes, microscopes). Optical tools can focus the laser
Infrared Thermometer. Users Manual ... The Fluke 62 MAX and 62 MAX Infrared Thermometers (the Product) can determine the surface temperature by measuring ...
File Info : application/pdf, 21 Pages, 1.43MB
DocumentDocument62 MAX/62 MAX + Infrared Thermometer Users Manual PN 4060712 April 2012 Rev. 1, 11/12 © 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks of their respective companies. Table of Contents Title Page Introduction ................................................................................................................. 1 How to Contact Fluke ................................................................................................. 1 Safety Information ...................................................................................................... 2 Maintenance ............................................................................................................... 6 How to Change the Battery .................................................................................... 6 How to Clean the Product ...................................................................................... 6 Specifications ............................................................................................................. 7 Standards and Agency Approval ................................................................................ 9 The Product ................................................................................................................ 10 i 62 MAX/62 MAX + Users Manual ii Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target's surface. Note that the Japanese models indicate Celsius only. Warning Read all safety information before you use the Product. How to Contact Fluke To contact Fluke, call one of the following telephone numbers: · Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) · Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) · Canada: 1-800-36-FLUKE (1-800-363-5853) · Europe: +31 402-675-200 · Japan: +81-03-6714-3114 · Singapore: +65-6799-5655 · Anywhere in the world: +1-425-446-5500 1 62 MAX/62 MAX + Users Manual Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. Table 1 tells you about symbols used on the Product and in this manual. Warning To prevent eye damage and personal injury: · Read all safety Information before you use the Product. · Do not use the Product if it operates incorrectly. · Use the Product only as specified, or the protection supplied by the Product can be compromised. · Before you use the Product, inspect the case. Do not use the Product if it appears damaged. Look for cracks or missing plastic. 2 Infrared Thermometer Safety Information · See emissivity information for actual temperatures. Reflective objects result in lower than actual temperature measurements. These objects pose a burn hazard. · Do not look directly into the laser with optical tools (for example, binoculars, telescopes, microscopes). Optical tools can focus the laser and be dangerous to the eye. · Do not look into the laser. Do not point laser directly at persons or animals or indirectly off reflective surfaces. · Replace the batteries when the low battery indicator shows to prevent incorrect measurements. · Do not use the Product around explosive gas, vapor, or in damp or wet environments. · Use the Product only as specified or hazardous laser radiation exposure can occur. 3 62 MAX/62 MAX + Users Manual Symbol Table 1. Symbols Meaning Symbol Meaning Risk of danger. Important information. See Manual. This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 "Monitoring and Control Instrumentation" product. Do not dispose of this product as unsorted municipal waste. Go to Fluke's website for recycling information. 4 Symbol Infrared Thermometer Safety Information Table 1. Symbols (cont.) Meaning Symbol Meaning Warning. Laser. Conforms to European Union directives. Battery Conforms to relevant Australian standards. Conforms to China Metrology Certification 5 62 MAX/62 MAX + Users Manual Maintenance Caution To avoid damage to the Product, do not leave the thermometer on or near objects of high temperature. How to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16. How to Clean the Product Use soap and water on a damp sponge or soft cloth to clean the Product case. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. See Figure 17. 6 Infrared Thermometer Specifications Specifications Temperature Range Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C) Response Time (95 %) Spectral Response Emissivity Temperature Coefficient 62 MAX 62 MAX + -30 °C to 500 °C (-22 °F to 932 °F) -30 °C to 650 °C (-22 °F to 1202 °F) 0 °C: ±1.5 °C or ±1.5 % of reading, whichever is greater (32 °F: ±3 °F or ±1.5 % of reading, whichever is greater) -10 °C to <0 °C: ±2 °C (14 °F to <32 °F: ±4 °F) < -10 °C: ±3 °C (<14 °F: ±6 °F) 0 °C: ±1 °C or ±1 % of reading, whichever is greater (32 °F: ±2 °F or ±1 % of reading, whichever is greater) -10 °C to <0 °C: ±2 °C (14 °F to <32 °F: ±4 °F) < -10 °C: ±3 °C (<14 °F: ±6 °F) <500 ms (95 % of reading) <300 ms (95 % of reading) 8 to 14 microns 0.10 to 1.00 ±0.1 °C/°C or ±0.1 %/°C of reading (whichever is greater) 7 62 MAX/62 MAX + Users Manual Optical Resolution Display Resolution Repeatability (% of reading) Power Battery Life Weight Size Operating Temperature Storage Temperature Operating Humidity Operating Altitude Storage Altitude 10:1 12:1 (calculated at 90 % energy) (calculated at 90 % energy) 0.1 °C (0.2 °F) ±0.8 % of reading or ±1.0 °C ±0.5 % of reading or ±0.5 °C (2 °F), whichever is greater (1 °F), whichever is greater 1 AA IEC LR06 Battery 10 hours with laser and backlight on 8 hours with laser and backlight on 255 g (8.99 oz) (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches 0 °C to 50 °C (32 °F to 122 °F) -20 °C to 60 °C (-4 °F to 140 °F), (without battery) 10 % to 90 % RH non-condensing @ 30 °C (86 °F) 2000 meters above mean sea level 12,000 meters above mean sea level 8 Infrared Thermometer Standards and Agency Approval Ingress Protection Rating Drop Test Vibration and Shock EMC IP 54 per IEC 60529 3 meters IEC 60068-2-6 2.5 g, 10 to 200 Hz, IEC 60068-2-27, 50 g, 11 ms EN 61326-1:2006 EN 61326-2:2006 Standards and Agency Approval Compliance ............................................. EN/IEC 61010-1 Laser Safety ............................................ EN 60825-1 Class 2 Implement Standard ............................... Q/SXAV37 9 62 MAX/62 MAX + Users Manual The Product 1 2 gtt01.eps 10 Infrared Thermometer The Product 3 4 / 5 5 6 Max/Min/Avg/Diff gtt14.eps 11 62 MAX/62 MAX + Users Manual 7 + = 10 min OFF gtt16.eps 12 Infrared Thermometer The Product 8 9 10 0ºC 32ºF 30 Min 12 9 3 6 11 22ºC 72ºF 125°F gtt15.eps 13 62 MAX/62 MAX + Users Manual 12 38 mm @ 60 mm @ 100 mm @ 300 mm 600 mm 900 mm 13 33 mm @ 50 mm @ 85 mm @ 300 mm 600 mm 900 mm S 1.5" @ 2.4" @ 4" @ 12" 24" 36" D 62 MAX D:S = 10:1 S 1.4" @ 2" @ 12" 24" D 62 MAX + D:S = 12:1 3.4" @ 36" gtt08-11.eps 14 Infrared Thermometer The Product 14 70 21 gtt03.eps 15 62 MAX/62 MAX + Users Manual 15 75° 225° 75° gtt04.eps 16 16 + Infrared Thermometer The Product 17 gtt13.eps 17 62 MAX/62 MAX + Users Manual 18