Installation Guide for FISHER and PAYKEL models including: OM24NDTDX1, OM24NDTDX1 Built In Microwave Oven, Built In Microwave Oven, Microwave Oven, Oven
Fisher and Paykel Built In Microwave | Bill & Rod's Appliance, Inc.
File Info : application/pdf, 20 Pages, 2.56MB
DocumentDocumentCONVECTION SPEED OVEN OM24NDTDX1, OM24NMTDB1, OM24NDTDB1, OM24NDLX1, OM24NMTNB1 models INSTALLATION GUIDE US CA SAFETY AND WARNINGS ! WARNING! Electric Shock Hazard Failure to follow this advice may result in electric shock or death. · Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains electricity supply. · Connection to a good earth wiring system is absolutely essential and mandatory. · Alterations to the domestic wiring system must only be made by a qualified electrician. · Failure to follow this advice may result in electrical shock or death. ! WARNING! Fire Hazard Failure to follow this advice may result in overheating, burning, and injury. · Do not use adapters, reducers, or branching devices to connect this appliance to the mains power supply. · Failure to follow this advice may result in overheating, burning or fire. ! WARNING! Cut Hazard Failure to use caution could result in injury. · Take care: some edges are sharp. · Failure to use caution could result in injury or cuts. 2 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS! To avoid hazard, follow these instructions carefully before installing or using this appliance. Save these instructions for the local inspectors use. Please make this information available to the person installing the appliance doing so could reduce your installation costs. This oven is to be installed and connected to the electricity supply only by an authorized person. If the installation requires alterations to the domestic electrical system, call a qualified electrician. The electrician should also check that the socket cable section is suitable for the electricity drawn by the oven. The oven must be grounded. Installation must comply with your local building and electricity regulations. This appliance must be installed and connected to the mains power supply only by a suitably qualified person according to these installation instructions and in compliance with any applicable local building and electricity regulations. Failure to install the appliance correctly could invalidate any warranty or liability claims. If the power supply cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid a hazard. A circuit breaker is recommended. Do not use adaptors, reducers or branching devices to connect the oven to the mains electricity supply, as they can cause overheating and burning. Do not allow children and animals to stop or linger near the appliance when it is pulled out of the cabinet. Electrical requirements Connect oven with copper wire only. Do not cut the conduit. A U.L. listed conduit connector must be provided at the junction box. Do not ground to a gas pipe. Do not have a fuse in the grounding or neutral circuit. Fuse both sides of the line. A time delay fuse or circuit breaker is recommended. If using a time delay fuse, then fuse both sides of the line. Flexible armored cable from the appliance should be connected directly to the junction box. Connect directly to the fused disconnect (or circuit breaker box) through flexible, armored or non-metallic sheathed, copper cable (with grounding wire). If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path and wire gauge are in accordance with local codes. SAVE THESE INSTRUCTIONS The models shown in this installation guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website www.fisherpaykel.com or contact your local Fisher & Paykel dealer. 3 SAFETY AND WARNINGS Grounding Instructions For all cord-connected appliances: This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING: Improper use of the grounding can result in a risk of electric shock. Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded, and either: If it is necessary to use an extension cord, use only a 3-wire extension cord, use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance. The marked rating of the extension cord shall be equal to or greater than the electrical rating of the appliance, or Do not use an extension cord. If the power supply cord is too short, have a qualified electrician or serviceman install an outlet near the appliance. For a permanently connected appliance: This appliance must be connected to a grounded, metallic, permanent wiring system, or an equipment grounding conductor should be run with the circuit conductors and connected to the equipment terminal or lead on the appliance. 4 COMPONENTS REQUIRED Supplied F Powered driver F Cross-head screwdriver TOOLS Supplied F Screw SD #7X13 PAN PH ZP PARTS All imagery shown in this guide is representative. Your product may differ. 5 ACCESSING YOUR PRODUCT SPECIFICATIONS For full product, cabinetry and service specifications, refer to the Planning Guide. To access the Planning Guide, scan the QR code or visit fisherpaykel.com/specify. Search by appliance type, product name or model code. B C e A D g A B C D E F G H i 6 INCHES min. 17 5/16 min. 22 1/16 min. 21 5/8 17 1/8 21 7/8 21 7/16 18 23 7/16 13/16 MM min. 440 min. 560 min. 550 435 556 545 458 596 20 f i H PRIOR TO INSTALLATION Ensure that: The cavity ventilation has been set up correctly. The countertop and oven cavity are square and level, and are the required dimensions. The installation will comply with all clearance requirements and applicable standards and regulations. The isolating switch will be easily accessible to the customer with the oven installed. The electrician provides sufficient free length of power supply cable to reach from the bottom rear of the cavity to at least 59 1/16" (1.5m) in front of the bottom edge of the opening. The cable may enter the cavity from the side, top or bottom, but top entry must be at the rear of the cavity. The oven connection socket (if fitted) is outside the cavity if the oven is flush to the rear wall. The oven will rest on a surface that can support its weight. The height from the floor suits the customer. You consult local building authorities and by-laws if in doubt regarding installation. Some environmental factors and cooking habits can cause condensation in and around the oven during use. To protect surrounding cabinetry from possible damage caused by frequent or excessive condensation, we recommend moisture-proofing the oven cavity. 7 SERVICES z This oven is not shipped with a power cable. z This oven must be connected to the mains power supply only by a suitably qualified person. z This oven must be earthed. Before connecting the oven to the mains power supply, check that: the domestic wiring system is suitable for the power drawn by the oven (as specified on the rating plate) the voltage corresponds to the value given on the rating plate. HZ VOLTAGE (V) AMPS (A) 60 208/240 23 8 CHECK CAVITY fisherpaykel.com/specify 1. Measure cavity dimensions. Ensure all minimum specifications have been met. Refer to the planning guide for details. For dark cabinetry, ensure clashing has been considered and installed. 2. Ensure service access complies with local requirements. 3. Ensure cavity ventilation has been set up correctly. 9 UNPACK PRODUCT z Do not lift or move the product using the door handle (handle models only). z Keep all packing materials until the unit has been inspected. z Inspect the product to ensure there is no shipping damage. If any damage is detected contact the dealer or retailer you brought the product from to report the damage. z Fisher & Paykel is not responsible for shipping damage. 1. Remove the carton sleeve, top cap, corner posts and any transit packaging. 2. Set aside any accessories. Dispose of packaging responsibly. 10 REMOVE SHELVES 1. Open the door and remove all packaging holding the oven shelves in place. 2. Grip the shelves at the front. Lift upwards and pull out from the microwave. 11 CONNECT POWER FOUR WIRE CONNECTION 1. Disconnect the power supply and remove the junction box cover. 2. Connect the oven cable to the junction box through the U.L - listed confuit connector. 3. Connect the two black wires together with twist-on connectors and the two red wires together with twist-on connectors. Connect electrical connection according to local codes and ordinances. 12 CONNECT POWER FOUR WIRE CONNECTION 4. Seperate the green and white oven cable wires. Connect the white oven cable wire to the neutral (white) wire in junction box. 5. Connect the green grounding oven cable wire to the (green) grounding wire in the junction box. Do not connect the green grounding wire to the neutral (white) wire in junction box. 6. Replace the junction box cover. 13 POSITION OVEN IN CAVITY 1. Some models only* For dark cabinetry, the supplied trim can be used to enhance clashing finish. To install, remove the trim adhesive and press to secure to cavity. 2. Lift product into cavity. *To purchase cabinetry trim as an optional accessory, visit fisherpaykel.com 14 ALIGN AND SECURE 1. Align oven with surrounding cabinetry and appliances. 2. Using the product as a guide, pre-drill 2 x 1/8" (3mm) pilot holes. 3. Secure oven to cavity using the 2 x #7x13 pan head screws provided. 15 REFIT SHELVES 1. Reposition shelves in the oven at the desired level. 2. Ensure shelves are level and correctly positioned with the guard rail at the back. 16 ALIGN AND SECURE 1. Follow the guidance on screen to ensure oven turns on and heats correctly. Refer to your User Guide for more information. 17 INSTALLER CHECKLIST To be completed by the installer F Make sure the oven is level and securely fitted to the cabinetry. F Open the oven door (lower) slowly until it is fully open and check there is adequate clearance between the bottom of the door and the lower trim. This is to ensure correct air circulation. Should the lower trim become damaged, straighten the trim and ensure the oven door opens fully without obstruction. F Make sure any cable ties and internal packaging has been removed from the oven cavity. F Make sure all oven vents and openings are clear and free of any obstruction or damage. F Ensure cavity ventilation has been set up correctly. Failure to make sure all oven vents are clear may result in poor product performance. F Make sure the isolating switch is accessible by the customer. Complete and keep for safe reference: Model Serial no. Purchase date Purchaser Dealer address Installer's name Installer's signature Installation company Installation date 18 FISHERPAYKEL.COM © Fisher & Paykel Appliances 2024. All rights reserved. The models shown in this guide may not be available in all markets and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time. For current details about model and specification availability in your country, please go to our website or contact your local Fisher & Paykel dealer. 90002695C 12.24