Instruction Manual for ELSEMA models including: MC240 Double and Single Gate Controller, MC240, Double and Single Gate Controller, Single Gate Controller, Gate Controller
File Info : application/pdf, 36 Pages, 7.16MB
DocumentDocumentDouble & Single Gate Controller with Eclipse® Operating System (EOS) 9th Edition Eclipse® MC www.elsema.com MC : Controller for Double and Single Gates Setup and Technical Information Includes latest Intelligent Technology Important warning and safety instructions All installations and testing must be done only after reading and understanding all instructions carefully. All wiring should be done only by trained technical personnel. Failing to follow instructions and the safety warnings may result in serious injury and/or damage to property. Elsema Pty Ltd shall not be liable for any injury, damage, cost, expense or any claim whatsoever to any person or property which may result from improper use or installation of this product. Risk in the goods purchased shall unless otherwise agreed in written pass to the buyer upon delivery of the goods. Any figures or estimates given for performance of goods are based upon the company's experience and is what the company obtains on tests. The company will not accept liability for failure to comply with the figures or estimates due to the nature of variable conditions affecting for example Radio Remote Controls. Elsema Pty Ltd recommends that safety devices such as Photo Electric beam and safety edge sensor are installed on automatic openers. Please keep this setup instruction for future reference. Installed by: ______________________________________ Service date: _____________________________________ 2 Double Gate & Door Controller with Eclipse® Operating System (EOS) Contents Features ..............................................................................................................................4 Description.......................................................................................................................... 4 Part Number........................................................................................................................5 Menu Structure ...................................................................................................................6 Connection Diagram ...........................................................................................................8 Setup Instructions ...............................................................................................................9 Limit Switches...................................................................................................................10 Setup i-Learning Steps......................................................................................................11 Menu 1 Auto Close ........................................................................................................12 Menu 2 Pedestrian Access Features ..............................................................................13 Menu 3 Input Functions.................................................................................................14 Menu 4 Photoelectric Beam ...........................................................................................15 Menu 5 Relay Output Functions.....................................................................................16 Menu 6 Relay Output Modes..........................................................................................19 Menu 7 Special Features................................................................................................22 Menu 8 Leaf Delay .........................................................................................................23 Menu 9 Motor 1 Obstruction .........................................................................................24 Menu 10 Motor 2 Obstruction .......................................................................................25 Menu 11 Motor Speed, Slow Speed Area and Reverse Time..........................................26 Menu 12 Anti-Jam and Braking ....................................................................................27 Menu 13 i-Learning .......................................................................................................28 Menu 14 Password ........................................................................................................28 Menu 15 Operational Records........................................................................................28 Menu 16 Tools...............................................................................................................29 Troubleshooting guide ......................................................................................................30 Accessories ....................................................................................................................... 32 www.elsema.com 3 Features > Suitable for swing and sliding gates > Double or single motor operation > Eclipse Operating System (EOS) > Day and night sensor (DNS) > 24 or 12 Volt DC motor operation > Motor soft start and soft stop > Speed and force adjustment > Large 4-line LCD to indicate controllers status and setup instructions > 1-Touch control for easy setup > Auto profiling using latest intelligent technology > Various inputs, push button, open only, close only, stop, pedestrian and Photoelectric Beam Description > Supports limit switch inputs or mechanical stops > Adjustable Auto Close, obstruction load and pedestrian access > Adjustable lock and courtesy light outputs > Variable photoelectric safety beam functions > Built-in Penta Receiver > Energy saving mode to reduce running costs > 12 and 24 Volt DC Output to power accessories > Service counters, password protection, holiday mode and many more features > Built in 12 and 24 Volt battery charger for backup batteries > Very low standby current making it ideal for solar gates Are you ready for the Eclipse? The MC's Eclipse operating system is a user friendly menu driven system that uses the 1-touch button to control, setup and run automatic gates, doors and barriers. It uses a large 4-line LCD screen showing live reading of the motor performance and status of all inputs and outputs. The MC controller is not just the next generation but the industry game changer. We wanted to create a controller that is simple to use and does just about any feature required in the gate and door industry. The MC is not just the next generation but the "Next Transformation" in the gate and door industry creating an Eclipse over previously developed motor controllers. This new intelligent motor controller is the best match for your automatic gate or door motors. The intelligent controller was built from the ground up, based on customer feedback and using todays technology. With its rich functions, consumer friendly price and with the focus during development being ease of use and setup makes this controller the ultimate board to control your motors. Elsema's easy options to add remote controls or any type of Photoelectric Beams makes for a very user friendly approach, while avoiding the lockdown approach to accessories. The control cards are available with an IP66 rated plastic enclosure for outdoor installations, backup batteries with charger or the card only. The MC is also suitable for solar gates with its very low standby current. 4 Double Gate & Door Controller with Eclipse® Operating System (EOS) MC MC24E2 MC24E or MC12E Solar24SP or Solar12 Part Number: Part No. Contents Part No. Contents MC Double or single gate and door controller for 24 / 12 Volt motor up to 120 Watts MCv2* Double or single gate and door controller for 24 / 12 Volt motor bigger than 120 Watts* MC24E Double or single controller for 24 Volt motors includes IP66 rated plastic enclosure and transformer MC12E Double or single controller for 12 Volt motors includes IP66 rated plastic enclosure and transformer MC24E2 Same as MC24E plus 24 Volt 2.3Ah backup battery MC24E7 Same as MC24E plus 24 Volt 7.0Ah backup battery MC12E7 Same as MC12E plus 12 Volt 7.0Ah backup battery Solar Gates Solar kit for double or single gates, includes solar Solar24SP MPPT charger & 24 Volt 15.0Ah backup battery and a 40W solar panel. Solar12 Solar kit for double or single gates, includes solar MPPT charger & 12 Volt 15.0Ah backup battery *Above 120 Watts use MCv2. Contact Elsema for recommended settings. MC & MCv2 control card can be used to control automatic gates, doors, boom gates, automated windows & louvres. www.elsema.com 5 Menu Structure Press Master Control for 2 seconds to enter the menu MAIN SCREEN 1.0 Auto Close 2.0 Pedestrian Access 3.0 Input Functions 4.0 PE Safety Beam Function 5.0 Output Functions 1.1 Auto Close Time 2.1 PA Travel Time 3.1 PE Polarity 4.1 Stop & Open on Close Cycle 5.1 Relay Output 1 Lock / Brake Courtesy Light Service Call Strobe (Warning) Light Locking Actuator Gate Open 1.2 AC Time with PE Trig 2.2 PA AC Time 3.2 Limit Sw Polarity PE Beam Stops Motor on Close Cycle 5.2 Relay Output 2 Lock / Brake Courtesy Light Service Call Strobe (Warning) Light Gate Open 6.0 Output Modes 7.0 Special Features 8.0 Leaf Delay 9.0 Motor 1 Obstruct Detect Margin 10.0 Motor 2 Obstruct Detect Margin 11.0 Motor Speed, Slow Speed Area & Reverse Time 12.0 Anti-Jam / Electronic Braking 13.0 Travel Learn 14.0 Password 15.0 Operational Records 16.0 Tools 6.1 Lock Output 7.1 RC Open only 8.1 Open Leaf Delay 9.1 M1 Open Obstruct 10.1 M2 Open Obstruct 11.1 Open Speed (%) 12.1 M1 Open Anti-Jam 6.2 Light Output 7.2 Holiday Mode 8.2 Close Leaf Delay 9.2 M1 Close Obstruct 10.2 M2 Close Obstruct 11.2 Close Speed (%) 12.2 M1 Close Anti-Jam 14.1 Enter Password 15.1 Events History 16.1 No. of Motors 1/2 14.2 Delete Password 15.2 Display Operations / Currents 16.2 Supply Voltage EXIT PROGRAMMING 6 Double Gate & Door Controller with Eclipse® Operating System (EOS) 1.3 AC After Open Obstruct 2.3 PA AC Time with PE Trig 3.3 Stop Input Polarity PE Beam Stops Motor on Open & Close Cycle 5.3 EXIT 1.4 AC After Power Restored 2.4 PA AC on Seq. Obstruct 3.4 Auxiliary Input PE Beam Stops Motor and Closes Gate on Open Cycle 1.5 AC on Seq. Obstruct 2.5 PA Hold Gate 3.5 EXIT 4.2 EXIT 6.3 Strobe (Warning) Light 7.3 Energy Saving 8.3 Close Leaf Delay on Mid Open 9.3 M1 Slow Speed Obstruct 10.3 M2 Slow Speed Obstruct 11.3 Slow Speed (%) 12.3 M2 Open Anti-Jam 6.4 Service Call 7.4 Automatic Stop/Open on Closing 8.4 EXIT 9.4 M1 Obstruct Det Response 10.4 M2 Obstruct Det Response 11.4 Open Slow Speed Area 12.4 M2 Close Anti-Jam 6.5 Locking Actuator 7.5 Receiver Channel 2 Options 9.5 EXIT 10.5 EXIT 11.5 Close Slow Speed Area 12.5 Electronic Braking 14.3 EXIT 15.3 Reset Max Current Records 16.3 Reset Factory Default 15.4 EXIT 16.4 Test Inputs 16.5 Travel Timer for Slip Motors 1.6 AC Only When Fully Open 2.6 EXIT 6.6 EXIT 7.6 Press and Hold, Open Input 11.6 Stop Rev Delay Time 12.6 Open Obstruction Operation 16.6 Solar Gate Mode 1.7 AC Only at Night 1.8 EXIT 7.13 EXIT 7.12 Momentary Reverse Stop 7.11 Press and Hold, Remote Ch2 7.10 Press and Hold, Remote Ch1 7.9 Wind Loading 7.8 Window / Louvre Mode 7.7 Press and Hold, Close Input 11.7 EXIT 12.7 Close Obstruction Operation 12.8 EXIT 16.7 Fuse Type : 10 or 15 Amps 16.10 EXIT 16.9 Slow Speed Ramp Down 16.8 Day / Night Sensitivity www.elsema.com 7 MC Connection Diagram 140mm Day and Night Sensor ACDSNuSpply Powered By Eclipse operating system Receiver 16 15 14 13 12 11 10 9 Program 2 1 2 3 4 5 6 7 8 Program 1 Master Control ELSEMA Open Close Stop LED Antenna Built-in Receiver + Output 2 C Output 2 NC Output 2 NO Power Output 130mm Fuse Relay Relay AACCSSuppplplyy AACCSSuppplplyy AMCoStuoprpl1y AMCoStuoprpl1y AMCoStuoprpl2y AMCoStuoprpl2y ABCatStueprpyly+ ABCatStueprpyly- Motor 1 Open Limit Motor 1 Close Limit Common Motor 2 Open Limit Motor 2 Close Limit Push Button Open Close Stop Common PED Access Photo Beam + 12 VDC - 12 VDC Output 1 C Output 1 NO Normally Closed User can change Normally Open Normally Closed User can change User can change Output Rated at 250mA DNS Connection : On the top right corner of the control card is a connection for Day and Night Sensor (DNS). This sensor is available from Elsema and is used to detect daylight. This feature can be used to Auto Close the gate at night, turn on the courtesy light or lights on your gates during the night and many more features which require a day and night detection. 8 Double Gate & Door Controller with Eclipse® Operating System (EOS) Electrical Wiring - Supply, Motors, Battery and Inputs Always switch off power before doing any wiring. Make sure that all the wiring is completed and that the motor is connected to the control card. Recommended wire strip length should be 12mm for all connections to the plug in terminal blocks. The diagram below shows the supply, motors, battery backup and inputs available and the factory default setting for each input. Fuse AC Supply : 24/12 Volts AC Model : MC Designed by ELSEMA IN AUSTRALIA Open Close Stop LED Relay AACC Suuppplplyy AACC Suuppplplyy AMCoStuoprpl1y AMCoStuoprpl1y AMCoStuoprpl2y AMCoStuoprpl2y ABCatStueprpyly+ ABCatStueprpylyMotor 1 Open Limit Motor 1 Close Limit Common Motor 2 Open Limit Motor 2 Close Limit Push Button Open Close Stop Common PED Access Photo Beam 12 or 24 Volts AC Supply M Motor 1 M Motor 2 Normally Closed User can change Normally Open User can change Normally Closed User can change If you are using mechanical stops move to the Setup i-Learning Steps. Skip Limit Switch section. If you are using limit switches make sure they are connected properly. The control card can operate with either the limit switches connected directly to the cards terminal blocks or in series with the motor. www.elsema.com 9 Before Setup: The MC control card can be installed in a variety of installtion setup. Below are 3 common setup. It is very important to select the correct setup type during i-Learn. 1. No limit switches. In this setup, the card relies on the current draw of the motor to determine the fully open and fully closed positions. You need to adjust your margins accordingly to get the gate to fully open and closed. Setting margins too high can cause the motor to stall in the open or closed postion. (See troubleshooting guide). 2. Limit switches connected to the Control card. The limit switches can be Normally Closed (NC) or Normally Open (NO). You need to select the correct type during i-Learn. In this setup the limit switches are wired directly to the control card. 2. Limit switches in series with the motor. The limit switches are connected in series with the motor. The limit switches will disconnect power to the motor when activated. Setup i-Learning Steps: 1. Look at the LCD and follow the instructions displayed. 2. The i-Learning setup can always be interrupted with the stop button or by pressing the Master Control knob. 3. Enter Menu 13 to start i-Learning or new control cards will automatically prompt you to do the i-Learning. 4. The control card will open and close the gates or doors several times to learn the load and travel distances. This is the auto profiling using latest intelligent technology. 5. Buzzer will indicate learning was successful. If there was no buzzer check all electrical wiring including the power supply then go back to step 1. 6. If you hear the buzzer after the i-Learn, the gate or door is ready for use. 10 Double Gate & Door Controller with Eclipse® Operating System (EOS) Limit Switches If you are using limit switches make sure they are connected properly. The control card can operate with either the limit switches connected directly to the cards terminal blocks or in series with the motor. Check diagrams below: Fuse AC Supply : 24/12 Volts AC Model : MC Designed by ELSEMA IN AUSTRALIA Limit switch connected directly to the control card AMCoStuoprpl1y AMCoStuoprpl1y AMCoStuoprpl2y AMCoStuoprpl2y Motor 1 Open Limit Motor 1 Close Limit Common Motor 2 Open Limit Motor 2 Close Limit M Motor 1 M Motor 2 Normally Closed User can change Fuse AC Supply : 24/12 Volts AC Model : MC Designed by ELSEMA IN AUSTRALIA Limit switch in series with motor AMCoStuoprpl1y AMCoStuoprpl1y AMCoStuoprpl2y AMCoStuoprpl2y Open Limit Close Limit Diode* Diode* M Open Limit Close Limit Diode* Diode* M * 6 Amps, 50V or better diode Elsema : Diode FR604 By default the limit switch inputs on the control card are normally closed (NC). This can be changed to normally open (NO) during the setup steps. www.elsema.com 11 Menu 1 Auto Close Auto Close feature automatically closes the gate after a preset time has counted down to zero. The control card has a normal Auto Close and several special Auto Close features each one having its own countdown timers. Elsema Pty Ltd recommends a Photoelectric Beam to be connected to the control card when any of the Auto Close options are used. If the Stop input is activated Auto Close is disabled for that cycle only. Auto Close timer will not count down if the Push Button, Open or Photoelectric Beam input is held active. Menu No. Auto Close Features Factory Default Adjustable 1.1 Normal Auto Close Off 1 - 600 seconds 1.2 Auto Close with Photoelectric Trigger Off 1 - 60 seconds 1.3 Auto Close after an Open Obstruction Off 1 - 60 seconds 1.4 Auto Close after Power Restored 1.5 Normal Auto Close on Sequential Obstructions 1.6 Auto Close Only when Fully Opened Off 1 - 60 seconds 2 Min = Off, Max = 5 Off Off / On 1.7 Auto Close Only at Night with DNS connected Off Off / On 1.8 Exit 1.1 Normal Auto Close The gate will close after this timer has counted down to zero. 1.2 Auto Close with Photoelectric Trigger This Auto Close starts counting down as soon as the Photoelectric Beam has been cleared after a trigger even if the gate is not fully open. If there is no Photoelectric Beam trigger the gate will not Auto Close. 1.3 Auto Close after an Open Obstruction If the gate opens and hits an obstruction normally the gate will stop and remain in this position. If this feature is enabled an obstruction will start the timer count down and at zero will close the gate. 12 Double Gate & Door Controller with Eclipse® Operating System (EOS) 1.4 Auto Close after Power Restored If the gate is open in any position and there is a power failure, when power is reconnected the gate will close with this timer. 1.5 Normal Auto Close on Sequential Obstructions If the normal Auto Close is set and during closing there is an obstruction, the gate will stop and reopen. This setting sets the amount of times the gate will try to Auto Close. After trying for the set limit the gate will remain open. 1.6 Auto Close Only when Fully Opened The Auto Close timer will not time out unless the gate is fully opened. 1.7 Auto Close Only at Night When the DNS is connected and the sensitivity (Menu 16.8) is set correctly, the Auto Close will only work at night. Menu 2 Pedestrian Access There are several types of Pedestrian Access modes. Pedestrian Access opens the gate for a short time to allow someone to walk through the gate but does not allow access to a vehicle. Elsema Pty Ltd recommends a Photoelectric Beam should be connected to the control card when any of the Auto Close options are used. Menu No. Pedestrian Access Features Factory Default Adjustable 2.1 Pedestrian Access Travel Time 3 seconds 3 - 20 seconds 2.2 Pedestrian Access Auto Close Time Off 1 - 60 seconds 2.3 Pedestrian Access Auto Close Time with PE trigger Off 1 - 60 seconds 2.4 Pedestrian Access Auto Close on Sequential Obstructions 2 Min = Off, Max = 5 2.5 Pedestrian Access with Hold Gate Off Off / On 2.6 Exit www.elsema.com 13 2.1 Pedestrian Access Travel Time This sets the time the gate opens when a Pedestrian Access input is activated. 2.2 Pedestrian Access Auto Close Time This sets the countdown timer for automatically closing the gate when a Pedestrian Access input is activated. 2.3 Pedestrian Access Auto Close Time with PE Trigger This Auto Close starts counting down as soon as the Photoelectric Beam has been cleared after a trigger, when the gate is in the Pedestrian Access position. If there is no Photoelectric Beam trigger the gate will remain in Pedestrian Access position. 2.4 Pedestrian Access Auto Close on Sequential Obstructions If the Pedestrian Access Auto Close is set and the gate closes onto an object the gate will stop and reopen. This setting sets the amount of times the gate will try to Auto Close. After trying for the set limit the gate will remain open. 2.5 Pedestrian Access with Hold Gate If the Pedestrian Access hold gate is ON and the Pedestrian Access input is permanently activated the gate will remain open in the Pedestrian Access position. Open input, Close input, Push Button input and remote controls are disable. Used in Fire Exit applications. Menu 3 Input Functions This allows you to change the Polarity of Photoelectric Beam, stop and limit switch inputs. Menu No. Input Functions Factory Default Adjustable 3.1 Photoelectric Beam Polarity 3.2 Limit Switch Polarity 3.3 Stop Input Polarity 3.4* Auxiliary Input (M2 Open Limit Terminal) Normally Closed Normally Closed Normally Open Disabled Normally Closed / Normally Open Normally Closed / Normally Open Normally Open / Normally Closed Disable / Safety Bump Strip 3.5 Exit * 3.4: This option is only available when used for single gate mode Motor 2 Open Limit terminal can be used to wire Elsema's safety bump strip on a single gate application. Its functions are the same as it's set in menu 12.7. 14 Double Gate & Door Controller with Eclipse® Operating System (EOS) Menu 4 Photoelectric Beam The Photoelectric Beam or sensor is a safety device which is placed across the gate and when the beam is obstructed it stops a moving gate. The operation after the gate stops can be selected in this menu. Menu No. Photoelectric Beam Feature Factory Default 4.1 Photoelectric Beam PE Beam stops and opens gate on close cycle 4.2 Exit Adjustable PE Beam stops and opens gate on close cycle -----------------------------------PE Beam stops gate on close cycle -----------------------------------PE Beam stops gate on open & close cycle -----------------------------------PE Beam stops and closes gate on open cycle The factory default for the PE beam input is "normally closed" but this can be changed to normally open in menu 3. Elsema Pty Ltd recommends a Photoelectric Beam to be connected to the control card when any of the Auto Close options are used. Elsema sells different types of Photoelectric Beams. We stock Retro-Reflective and Through Beam Photoelectric Beams. PE1500 (Retro-Reflective Type) www.elsema.com PE24 (Through-Beam type) 15 Menu 5 Relay Output Functions The control card has two relay outputs, Output 1 and Output 2. The user can change the function of these outputs to lock / brake, courtesy light, service call, strobe (Warning) light, locking actuator or gate open (gate not fully closed) indicator. Output 1 is a voltage free relay output with common and normally open contacts. Factory default is lock / brake release function. Output 2 is a voltage free relay output with common, normally open and normally closed contacts. Factory default is courtesy light function. Menu No. Relay Output Function Factory Default 5.1 Relay Output 1 Lock / Brake Adjustable Lock / Brake ------------------------------------ Courtesy Light ------------------------------------ Service Call ------------------------------------ Strobe (Warning) Light ------------------------------------ Locking Actuator ------------------------------------ Gate open 5.2 Relay Output 2 Courtesy Light Lock / Brake ------------------------------------ Courtesy Light ------------------------------------ Service Call ------------------------------------ Strobe (Warning) Light ------------------------------------ Gate Open 5.3 Exit 16 Double Gate & Door Controller with Eclipse® Operating System (EOS) Lock / Brake Output The factory default for output 1 is lock/ brake release. Output 1 is a voltage-free relay contact with common and normally open contacts. Having it voltage-free allows you to connect either 12VDC/AC, 24VDC/AC or 240VAC to the common. The normally open contact drives the device. See diagram below: Relay Open Close Stop Relay Output 1 C Output 1 NO Power + Supply - + if DC - if DC Lock/Brake Lock or Brake connection + Output 2 C Output 2 NC Output 2 NO Relay Open Close Stop Relay + Power - Supply Maglock Output 1 C Output 1 NO Magnetic lock connection Use output 2 Courtesy Light The factory default for the courtesy light is on output 2. Output 2 is a voltage-free relay contact with common, normally open and normally closed contacts. Having it voltage-free allows you to connect either 12VDC/AC, 24VDC/AC or 240VAC supply to the common. The normally open contact drives the light. See diagram on the next page. Service Call Output Either output 1 or output 2 can be changed to service call indicator. This will trigger the output when the software service counter is reached. Used to alert installers or owners when service is due for the gate. Using Elsema's GSM receiver allows installers or owners to get a SMS message & a phone call when the service is due. www.elsema.com 17 R e c e i v e r Master Control + Output 2 C Output 2 NC Output 2 NO Relay Unfiltered DC Output Output voltage depends on supply voltage + Power - Supply 12VAC/DC 24VAC/DC or 240VAC supply Depends on the light Strobe (Warning) Light when Opening or Closing The relay output is activated whenever the gate are operating. The factory default is Off. Either output 1 or output 2 can be changed to strobe (Warning) light. Both relay outputs are voltage-free contacts. Having it voltage-free allows you to connect either 12VDC/AC, 24VDC/AC or 240VAC supply to the common to power the strobe light. Then the normally open contact drives the light. See diagram above. Locking Actuator Locking actuator mode uses both relay output 1 and relay output 2. The 2 outputs are used to change the polarity of the locking actuator to lock and unlock during opening and closing cycle. During preopen relay output 1 is "ON" and during post-close relay output 2 is "ON". Pre-open and post-close times are adjustable. Gate Open The relay output is activated whenever the gate is not fully closed. The factory default is Off. Either output 1 or output 2 can be changed to gate open. 18 Double Gate & Door Controller with Eclipse® Operating System (EOS) Menu 6 Relay Output Modes Menu 6.1 Lock / Brake The relay output in the lock / brake mode can be configured in different ways. Menu No. Lock / Brake Modes 6.1.1 Open Lock / Brake Activation 6.1.2 Close Lock / Brake Activation Factory Default 2 seconds Off Adjustable 1 30 seconds or hold 1 30 seconds or hold 6.1.3 Open Pre-Lock / Brake Activation Off 1 30 seconds 6.1.4 Close Pre-Lock / Brake Activation Off 1 30 seconds 6.1.5 Drop Lock Off Off / On 6.1.6 Exit 6.1.1 Open Lock / Brake Activation This sets the time the output is activated. Factory default is 2 seconds. Setting it to Hold means the output is activated for the total travel time in the open direction. 6.1.2 Close Lock / Brake Activation This sets the time the output is activated. Factory default is off. Setting it to Hold means the output is activated for the total travel time in the close direction. 6.1.3 Open Pre-Lock / Brake Activation This sets the time the output is activated before the motor starts in the open direction. Factory default is Off. 6.1.4 Close Pre-Lock / Brake Activation This sets the time the output is activated before the motor starts in the close direction. Factory default is Off. 6.1.5 Drop Lock This mode should be enabled when a drop lock is used. It will hold the lock if the gates are stopped in the middle of it's travel. www.elsema.com 19 Menu 6.2 Courtesy Light The relay output in the courtesy mode can be adjusted from 2 seconds to 18 hours. This sets the time the courtesy light is activated after the gate has stopped. Factory default is 1 minute. Menu No. 6.2.1 Courtesy Light Mode Courtesy Light Activation Factory Default 1 minute Adjustable 2 seconds to 18 hours 6.2.2 Courtesy Light at Night Only with DNS (Day and Night Sensor) Connected Off Off / On 6.2.3 Exit Menu 6.3 Strobe (Warning) Light The relay output in the strobe (Warning) light stays "on" while the gate is moving. This output can also be configured to come "on" before the gate starts to move. Menu No. Strobe (Warning) Light Mode 6.3.1 Pre-Open Strobe (Warning) Light Activation 6.3.2 Pre-Close Strobe (Warning) Light Activation Factory Default Off Off Adjustable 1 30 seconds 1 30 seconds 6.3.3 Exit 6.3.1 Pre-Open Strobe Light Activation This sets the time the strobe light is activated before the gate operates in the open direction. Factory default is Off. 6.3.2 Pre-Close Strobe Light Activation This sets the time the strobe light is activated before the gate operates in the close direction. Factory default is Off. 20 Double Gate & Door Controller with Eclipse® Operating System (EOS) Menu 6.4 Service Call This sets the number of complete cycles (open and close) required before the built-in buzzer is activated. Also the control card outputs can be configured to be activated if the number of cycles is completed. Connecting Elsema's GSM receiver to the output allows owners to get a phone call & SMS message when the service is due. When "Service Call Due" message shows up on the LCD a service call is required. After service has been done, follow the messages on the LCD. Menu No. 6.4.1 Service Call Mode Service Counter Factory Default Off Adjustable Min: 2000 to Max: 50,000 6.4.2 Exit Menu 6.5 Locking Actuator The time for which relay output 1 turns "on" before the gate starts to open and the time for which relay 2 turns "on" after the gate is fully closed can be adjusted as below: Menu No. Locking Actuator Factory Default Adjustable 6.5.1 Pre-Open Lock Activation Off 1 30 seconds 6.5.2 Post-Close Lock Activation Off 1 30 seconds 6.5.3 Exit 6.5.1 Pre-Open Locking Actuator Activation This sets the time relay 1 is activated before the gate operates in the open direction. Factory default is Off. 6.5.2 Post-Close Locking Actuator Activation This sets the time relay 2 is activated after the gate is fully closed. Factory default is Off. www.elsema.com 21 Menu 7 Special Features The control card has many special features that can all be customised to your specific application. Menu No. Special Features 7.1 Remote Control Open Only 7.2 Holiday Mode 7.3 Energy Saving Mode 7.4 Automatic Stop & Open on Closing 7.5 Receiver Channel 2 Options 7.6 Press and Hold for Open Input 7.7 Press and Hold for Close Input 7.8 Window / Louvre 7.9 Wind Loading 7.10 Press & Hold Remote Channel 1 (Open) 7.11 Press & Hold Remote Channel 2 (Close) 7.12 Momentary Reverse on Stop Input 7.13 Exit Factory Default Off Off Off On Off Off Off Off Off Off Off Off Adjustable Off / On Off / On Off / On Off / On Off / Light / Pedestrian Access / Close Only Off / On Off / On Off / On Off / Low / medium / High Off / On Off / On Off/On 7.1 Remote Control Open Only By default the remote control allows the user to open and close the gate. In public access areas user should only be able to open the gate and not worry about closing it. Usually the Auto Close is used to close the gate. This mode disables closing for the remote controls. 7.2 Holiday Mode This feature disables all the remote controls. 7.3 Energy Saving Mode This puts the control card to very low standby current that reduces your electricity bill while still maintaining normal functions and operations. 7.4 Automatic Stop & Open on Closing By default when the gate is closing and a push button or remote control is activated it will automatically stop and open the gate. When this feature is disabled, the gate will only stop on an activation of the push button or remote control. Automatic opening will be disabled. 7.5 Receiver Channel 2 Options The receivers 2nd channel can be programmed to control a courtesy light, pedestrian access or can be used for Close only. 22 Double Gate & Door Controller with Eclipse® Operating System (EOS) 7.6 & 7.7 Press and Hold for Open and Close Inputs If this feature is ON the user must continuously press the open or close input for the gate to operate. 7.8 Window or Louvre Mode This mode optimises the control card for operating automated windows or louvres. 7.9 Wind Loading Enable this mode for gates installed in High Wind area. 7.10 & 7.11 Press and Hold for Remote Channel 1 (Open) and Channel 2 (Close) The remote channel 1 & 2 buttons will need to be programmed to receiver channel 1 & 2. The user must press and hold the remote button for the gate to open or close. 7.12 Momentary Reverse on Stop Input When this feature is ON and if stop input is activated, both gates will stop and reverse for 1 sec. Menu 8 Leaf Delay Leaf delay is used when one gate leaf will close in an overlapping position to the first closed leaf. This leaf delay may also be necessary for special add-on locking pins. The control card has separate leaf delay for the open and close directions. When the control card is used with a single motor the leaf delay mode is disabled. Menu No. 8.1 Leaf Delay Open Leaf Delay Factory Default 3 seconds Adjustable Off - 25 seconds 8.2 Close Leaf Delay 3 seconds Off - 25 seconds 8.3 Close Leaf Delay on Mid Stop Off Off / On 8.4 Exit 8.1 Open Leaf Delay Motor 1 will start opening first. After leaf delay time has expired motor 2 will start opening. 8.2 Close Leaf Delay Motor 2 will start closing first. After leaf delay time has expired motor 1 will start closing. 8.3 Close Leaf Delay on Mid Stop By default motor 1 will always have delay when closing even if the gate is not fully open. When disabled both motor 1 and motor 2 will start closing at the same time only when not fully open. www.elsema.com 23 Menu 9 Motor 1 Obstruction Detect Margins This sets the current sensitivity margin above the normal run current to trip the gate if an obstruction is detected. Different obstruction margins can be set for the open and close direction. Also the response time is adjustable. The minimum margin will allow least pressure applied to trip the gate if it hits an object. The maximum margin will allow for a large amount of pressure applied to trip the gate if it hits an object. Menu No. Motor 1 Obstruction Detect Margins and Response Time Factory Default Adjustable 9.1 Open Obstruction Margin 1 Amp 0.2 - 6.0 Amps 9.2 Close Obstruction Margin 9.3 Open and Close Slow Speed Obstruction Margin 9.4 Obstruction Detect Response Time 9.5 Exit 1 Amp 1 Amp Medium 0.2 - 6.0 Amps 0.2 - 6.0 Amps Fast, Medium, Slow and Very Slow Margin Example Motor is running at 2 Amps and the margin is set to 1.5 Amps, an obstruction detect will occur at 3.5 Amps (Normal Running Current + Margin). For high margin settings the supply transformer should be large enough to supply the high margin current. If the gate hits an object on closing it will automatically stop and then re-open. If the gate hits an object on opening it will automatically stop. 24 Double Gate & Door Controller with Eclipse® Operating System (EOS) Menu 10 Motor 2 Obstruction Detect Margins This sets the current sensitivity margin above the normal run current to trip the gate if an obstruction is detected. Different obstruction margins can be set for the open and close direction. Also the response time is adjustable. The minimum margin will allow least pressure applied to trip the gate if it hits an object. The maximum margin will allow for a large amount of pressure applied to trip the gate if it hits an object. Menu No. Motor 2 Obstruction Detect Margins and Response Time Factory Default Adjustable 10.1 Open Obstruction Margin 1 Amp 0.2 - 6.0 Amps 10.2 Close Obstruction Margin 10.3 Open and Close Slow Speed Obstruction Margin 10.4 Obstruction Detect Response Time 10.5 Exit 1 Amp 1 Amp Medium 0.2 - 6.0 Amps 0.2 - 6.0 Amps Fast, Medium, Slow and Very Slow Margin Example Motor is running at 2 Amps and the margin is set to 1.5 Amps, an obstruction detect will occur at 3.5 Amps (Normal Running Current + Margin). For high margin settings the supply transformer should be large enough to supply the high margin current. If the gate hits an object on closing it will automatically stop and then re-open. If the gate hits an object on opening it will automatically stop. www.elsema.com 25 Menu 11 Motor Speed, Slow Speed Area and Reverse Time Menu No. Motor Speed, Slow Speed Area and Reverse Time 11.1 Open Speed Factory Default 80% 11.2 Close Speed 70% 11.3 Open and Close Slow Speed 50% 11.4 Open Slow Speed Area 4 11.5 Close Slow Speed Area 5 11.6 Stop Reverse Delay 0.4 seconds 11.7 Exit Adjustable 50% to 125% 50% to 125% 25% to 65% 1 to 12 1 to 12 0.2 to 2.5 seconds 11.1 & 11.2 Open and Close Speed This sets the speed at which the gate will travel. If the gate is travelling too fast reduce this value. 11.3 Slow Speed This sets the speed at which the gate will travel in the slow speed region. If the gate is travelling too slow increase this value. 11.4 & 11.5 Slow Speed Area This sets the slow speed travel area. If you want more travel time for the slow speed area increase this value. 11.6 Obstruction Stop Reverse Delay Time This sets the stop and reverse delay time when the gate hits an obstruction. 26 Double Gate & Door Controller with Eclipse® Operating System (EOS) Menu 12 Anti-Jam, Electronic Braking and Gate Movement after Obstruction Menu No. 12.1 Anti-Jam or Electronic Braking Motor 1 Open Anti-Jam Factory Default OFF Adjustable 0.1 to 2.0 seconds 12.2 Motor 1 Close Anti-Jam OFF 0.1 to 2.0 seconds 12.3 Motor 2 Open Anti-Jam OFF 0.1 to 2.0 seconds 12.4 Motor 2 Close Anti-Jam OFF 0.1 to 2.0 seconds 12.5 Electronic Braking OFF Off / On 12.6 Opening Direction : Gate Movement after Obstruction Gate Stops Stop / Reverse for 2 sec / Reverse Fully 12.7 Closing Direction : Gate Movement after Obstruction Reverse for 2 seconds Stop / Reverse for 2 sec / Reverse Fully 12.8 Exit 12.1 and 12.2 Motor 1 Open and Close Anti-Jam When the gate are in the fully open or fully closed position this feature applies a reverse voltage for a very short time. It will prevent the motor from jamming up the gate so it is easy to disengage the motors for manual operation. 12.3 and 12.4 Motor 2 Open and Close Anti-Jam When the gate are in the fully open or fully closed position this feature applies a reverse voltage for a very short time. It will prevent the motor from jamming up the gate so it is easy to disengage the motors for manual operation. 12.5 Electronic Braking This will stop the motors with an electronic brake. Brake applies to obstruction and Stop inputs. 12.6 Opening Direction : Gate Movement after Obstruction After an obstruction has occurred while opening, the gate will either stop, reverse for 2 seconds or reverse fully. 12.7 Closing Direction : Gate Movement after Obstruction After an obstruction has occurred while closing, the gate will either stop, reverse for 2 seconds or reverse fully. www.elsema.com 27 Menu 13 i-Learning This feature allows you to do the intelligent travel learning of the gate. Follow the messages on the LCD to complete the learning Menu 14 Password This will allow the user to enter a password to prevent unauthorised users from entering the control card settings. User must remember the password. The only way to reset a lost password is to send the control card back to Elsema. To delete a password select Menu 14.2 and press Master Control. Menu 15 Operational Records This is for information only. Menu No. 15.1 15.2 15.3 15.4 Operational Records Event History, up to 100 events are recorded in the memory Displays Gate Operations and Currents Levels Reset Maximum Current Records Exit 15.1 Event History The event history will store 100 events. The following events are recorded into the memory: Power On, Low Battery, All input activations, Successful Opening, Successful Closing, Obstruction Detected, Unsuccessful i-Learning Attempt, Factory Reset, DC Output Overloaded, AC Supply Failed, AC Supply Restored, Autoclose, Security Close and Fuse Protect Obstruction. 15.2 Displays Operations and Current Levels This displays the number of open cycles, close cycles, pedestrian cycles, open obstructions, close obstructions and both motor current levels. All maximum current values can be reset by the user in Menu 15.3 28 Double Gate & Door Controller with Eclipse® Operating System (EOS) Menu 16 Tools Menu No. 16.1 16.2 16.3 16.4 16.5 16.6 16.7 16.8 16.9 16.10 Tools Number of Motors, Single or Double Gate System Set the Supply Voltage : 12 or 24 Volts Resets Controller to Factory Settings Test Inputs Travel Timer for Slip Clutch Motors Solar Gate Mode : Optimises the Control Card for Solar Applications Fuse Type : 10 or 15 Amps Optimises the Control Card for the correct Blade Fuse used Day and Night Sensitivity Adjustment for the DNS Slow Speed Ramp Down Time Exit 16.1 Number of Motors This allows you to manually set the control card to a single or a double motor. The control card will automatically test for motors connected during setup. 16.2 Set the Supply Voltage This allows you to manually set the control card to 12 or 24 Volt supply. The control card will automatically set the correct supply voltage during setup. To use the control card in a solar application you must set the correct voltage in the Tools. This will disable the automatic voltage sensing which could causes problems in solar applications. 16.3 Resets Controller Reset all settings to factory default. Also removes password. 16.4 Test Inputs This allows you to test all the external devices connected to the controllers inputs. UPPERCASE means input is activated and lowercase means input is deactivated. 16.5 Travel Timer for Slip Clutch Motors This allows you to use the controller with travel timers. Motor 1 and 2 can have separate travel timers up to 120 seconds. Used for Hydraulic Motors. 16.9 Slow Speed Ramp Down Time This allows you to change the time it takes the gate to change its speed from fast to slow. www.elsema.com 29 LCD Display Explained Gate Status Input Status Limit Switch Status Gate Status Gate Opened Gate Closed Gate Stopped Obstruction Detected Limit Switch Status M1OpnLmON M2OpnLmON M1ClsLmON M2ClsLmON Input Status Opn ON Cls ON Stp ON PE ON PB ON PED ON Description Gate is in the fully open position Gate is in the fully close position Gate has been stopped by either one of the inputs or remote control Control card has sensed an obstruction Description Motor 1 Open limit switch is ON Motor 2 Open limit switch is ON Motor 1 Close limit switch is ON Motor 2 Close limit switch is ON Description Open input is activated Close input is activated Stop input is activated Photo Beam input is activated Push Button input is activated Pedestrian Access input is activated 30 Double Gate & Door Controller with Eclipse® Operating System (EOS) Troubleshooting Guide During i-Learn, the gate will open and close 3 times. First cycle is in slow speed. The second cycle is in fast speed. The third cycle will be in fast speed but the gate will slow down before reaching the end. Error during i-Learn i-Learn is stuck at 14% i-Learn is stuck at 28% Gates do not fully open or fully close in the 1st i-Learn cycle Remedy Decrease M1 and M2 Slow Speed Obstruction Margin (Menu 9.3 & 10.3) Decrease M1 and M2 Open Obstruction Margin (Menu 9.1 & 10.1) Increase M1 and M2 Slow Speed Obstruction Margin (Menu 9.3 & 10.3) Gates do not fully open or fully close in the 2nd i-Learn cycle Increase M1 and M2 Open or Close Obstruction Margin (Menu 9.1, 9.2 & 10.1, 10.2) Limit switch failed to register and the gate is not in the fully open or closed position. For 1st cycle. Increase M1 and M2 Slow Speed Obstruction Margin (Menu 9.3 & 10.3). For 2nd & 3rd cycle. Increase M1 and M2 Open or Close Obstruction Margin (Menu 9.1, 9.2 & 10.1, 10.2) Limit switch failed to register and the gate is in the fully open or closed position. Limit switch position is not correct. The gate has reached the physical stopper or it's maximum travel before the limit switch is activated. Error during Operation Remedy Gate does not fully open or fully close but the LCD says "Gate Opened" or "Gate Closed". Increase M1 and M2 Slow Speed Obstruction Margin (Menu 9.3 & 10.3) depending on which motor did not fully open or close. LCD says "Obstruction detected" when there is no obstruction. Increase M1 and M2 Open or Close Obstruction Margin (Menu 9.1, 9.2 & 10.1, 10.2) Gate does not respond to remotes or any local trigger. Check the LCD for Input status (see previous page). If any input is activated and held active, the card will not respond to any other command. www.elsema.com 31 Accessories Backup Batteries & Battery Charger The control card has a built in charger for backup batteries. Simply connect the batteries to the battery terminal and the charger will automatically charge the batteries. Elsema has a range of battery sizes. Solar Applications Elsema stocks solar gate controller kits, solar panels, solar chargers and full solar gate operators as well. WARNING To use the control card in a solar application you must set the correct voltage input in the Tools Menu (16.2). This will disable the automatic voltage sensing which could causes problems in solar applications. Pre-made Inductive Loops & Loop Detectors Elsema has a range of Saw-Cut and Direct Burial loops. They are pre-formed with recommended loop sizes for commercial or domestic applications and makes installation quick and easy. Wireless Bump Strip Safety edge bump strip is installed on the moving gate or barrier along with the transmitter. When the gate hits an obstacle, the transmitter transmits a wireless signal to the receiver to stop the gate from causing further damage. Backup Batteries Solar Panels Inductive Loop Loop Detectors Safety Bump Strip 32 Double Gate & Door Controller with Eclipse® Operating System (EOS) Keyring Remotes The latest PentaFOB® keyring remotes ensure your gates or doors are secure. Visit www.elsema.com for more details. PentaFOB® Remotes PentaFOB® Programmer Add, edit and delete PentaFOB® remotes from the receiver's memory. The receiver can also be password protected from unauthorised access. Booster for PentaFOB® remotes Penta Repeater can increase the operating range of the keyring remotes to up to 500 metres. Repeater/ booster for PentaFOB® remotes Flashing Lights Elsema has several flashing lights to act as a warning when the gate or doors is in operation. PentaFOB® Programmer Flashing Lights www.elsema.com 33 PentaFOB® Programming Instructions 1. Press and hold the program button on the built-in receiver (Refer to the MC connection diagram) 2. Press the remote button for 2 seconds while holding the program button on the receiver 3. Receiver LED will flash and then turn Green 4. Release the button on the receiver 5. Press remote control button to test the receiver output Deleting Receivers Memory Short the Code Reset pins on the receiver for 10 seconds. This will delete all the remotes from the receiver's memory. PentaFOB® Programmer This programmer allows you to add and delete certain remotes from the receiver memory. This is used when a remote control is lost or a tenant moves from the premises and the owner wants to prevent un-authorised access. PentaFOB® Backup Chips This chip is used to backup or restore the contents of a receiver. When there are 100's of remotes programmed to a receiver the installer normally backups the receiver memory in case the receiver is damaged. 34 Double Gate & Door Controller with Eclipse® Operating System (EOS) NOTES ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ www.elsema.com 35 Sliding gate motor kits Keyring remote controls Swinging gate motor kits Sliding gate motor kits Swinging gate motor kits Motor control cards & Kits ELSEMA PTY LTD 31 Tarlington Place Smithfield, NSW 2164 Australia P 02 9609 4668 W www.elsema.com