GREE MULTI18HP230V1CO Multi-Room Ductless Heat Pump System
Submittal Data
Model: MULTI18HP230V1CO
System Type: Multi-Room Ductless Heat-Pump System
Description: 18,000 BTU/H Wall Mounted Heat-Pump System
General Features
- Dual Indoor Units (2-Port)
- EnergyStar Rated
- G10 DC Inverter Technology
- Quiet Operation - Both Indoor & Outdoor
- Acrylic Resin/Anti-Corrosion Coil Protection
- Intelligent Defrost
- Auto Restart on Power Outages
- Multi-point Diagnostics
- Limited 5 yr Parts Warranty
System Ratings
Non-Ducted Indoor
Specification | Value |
Rated Cooling Capacity | 18,000 BTUH |
Cooling Capacity (min-max) | 7,000-21,000 BTUH |
Rated Heating Capacity | 19,000 BTUH |
Heating Capacity (min-max) | 8,530-22,600 BTUH |
SEER/EER | 22.0/12.5 |
HSPF/COP | 11.0/3.7 |
Ducted Indoor
Specification | Value |
Rated Cooling Capacity | 18,000 BTUH |
Cooling Capacity (min-max) | 7,000-21,000 BTUH |
Rated Heating Capacity | 19,000 BTUH |
Heating Capacity (min-max) | 8,530-22,600 BTUH |
SEER/EER | 16.0/11.5 |
HSPF/COP | 8.5/3.1 |
Operating Range
Mode | Temperature Range |
Cooling (min-max) | 0 ~ 118°F (-18 ~ 48°C) |
Heating (min-max) | -5 ~ 75°F (-21 ~ 24°C) |
Power Supply
Specification | Value |
Normal Operational Voltage | 208/230 V, 1 Phase, 60 Hz |
Voltage Range | 187 - 253 V |
Main Power Wire Size | 12-2 AWG |
Interconnecting Cable Wire Size | 14-4 AWG |
MCA | 16.0 A |
MOCP/Breaker Size | 25 A |
Outdoor Unit Data
Specification | Value |
Compressor Type | DC Inverter Driven Rotary |
RLA | 10.8 |
Compressor Crankcase and Base Pan Heaters | Included |
Fan Motor Output Power | 60 W |
FLA | 0.6 A |
Air Flow (Max) | 1883 CFM |
Sound Pressure Level (Cooling/Heating) | 56 dB(A) / 56 dB(A) |
Dimensions & Weights
Specification | Value |
Unit Dimensions (LxHxD) | 38.0 x 27.6 x 15.6 inches |
Weight (Net/Shipping) | 114.4/124.3 LBS |
Min. Number of Indoor Units | 1 |
Max. Number of Indoor Units | 2 |
Refrigerant Piping Data
Specification | Value |
Refrigerant Type | R410A |
Refrigerant Charge | 56.4 oz |
Additional Charge Per Line Length | 0.21-oz/ft |
Connection Method | Flared |
Factory Charge for Total Line Length | 33-ft |
Total Refrigerant Pipe Length | 65-ft |
Max Refrigerant Piping Length to any Indoor Unit | 33-ft |
Min Refrigerant Piping Length to any Indoor Unit | 10-ft |
Max Elevation between Indoor Units | 33-ft |
Max Lift from Outdoor to Indoor Unit | 33-ft |
Max Drop from Outdoor to Indoor Unit | 33-ft |
Features & Function Summary
System Features
Feature | Status |
Inverter Type | G10 |
Ultra Low Frequency Torque Control | YES |
Power Factor Correction | YES |
Compressor Type | Inverter Rotary |
Refrigerant Type | R410A |
Basepan With Electric Heater | YES |
Compressor With Electric Heater | YES |
Condenser Fan | Axial |
Condenser Motor Type | DC |
Condenser Motor Drive | Direct |
Condenser Coil | Aluminum Fin/Copper Tube |
Outdoor Fin Coating (Blue) | Acrylic Resin |
Intelligent Defrosting | YES |
Low Voltage Startup | YES |
Memory/Power Failure Recovery | YES |
Self Diagnosis | YES |
Low Ambient Cooling | YES |
XK19 Wired Controller Interface | YES |
XK19 Wired Controller Functions
Function | Supported |
On/Off | YES |
Operating Mode | YES |
Fan Speed | YES |
Room Setpoint | YES |
Model Numbers | YES |
Timer Mode | YES |
Sleep Mode | YES |
Turbo Mode | YES |
X-Fan Mode | YES |
Privacy Lock | YES |
Note: Some indoor models may not support specific system features or functions.
Dimensional Specifications
Model: MULTI18HP230V1CO 18,000 BTUH 230V
Outdoor Unit Dimensions: Approximately 38.0 inches wide, 27.6 inches high, and 15.6 inches deep.
Factory Supplied Piping Adapters
Adapter | P/N | Qty |
3/8 (F) to 1/2 (M) | 6643008 | 2 |
Piping Port Sizes
Line Type | Port | Size |
Suction/Gas Line | Port A | 3/8-in OD Flared |
Suction/Gas Line | Port B | 3/8-in OD Flared |
Liquid Line | Port A | 1/4-in OD Flared |
Liquid Line | Port B | 1/4-in OD Flared |
Minimum Spacing Requirements
Clearance is required around the outdoor unit for proper airflow and maintenance. Recommended clearances include:
- 20 inches (0.5m) on the sides for air inlet.
- 78 inches (2.0m) for the air outlet.
- 12 inches (0.3m) for the top and front.
Operational Performance Specifications
Cooling Capacity (BTUH)
Indoor Units Combinations | Rated System Capacity (BtuH) | Indoor Unit Capacities (BtuH) |
Unit A | Unit B | Unit C | Unit D |
9K | 18,000 | 9,000 | NA | NA | NA |
12K | 21,000 | 12,000 | NA | NA | NA |
9K+9K | 18,000 | 9,000 | 9,000 | NA | NA |
9K+12K | 16,719 | 6,824 | 9,895 | NA | NA |
12K+12K | 16,718 | 8,359 | 8,359 | NA | NA |
Heating Capacity (BTUH)
Indoor Units Combinations | Rated System Capacity (BtuH) | Indoor Unit Capacities (BtuH) |
Unit A | Unit B | Unit C | Unit D |
9K | 19,000 | 9,000 | NA | NA | NA |
12K | 19,000 | 11,874 | NA | NA | NA |
9K+9K | 18,000 | 9,000 | 9,000 | NA | NA |
9K+12K | 20,063 | 8,189 | 11,874 | NA | NA |
12K+12K | 20,062 | 10,031 | 10,031 | NA | NA |
Capacity data is based on the following conditions:
- Cooling Nominal Test Conditions: Indoor: 80°F DB/67°F WB; Outdoor: 95°F DB/75°F WB
- Heating Nominal Test Conditions: Indoor: 70°F DB/60°F WB; Outdoor: 47°F DB/43°F W
Extended Ratings
Cooling Performance
(Values in BtuH for TC/SC, Watts for Input Power)
Outdoor Ambient Temperature (DB) | Indoor Ambient Temperature 70°F (21°C) / 59°F (15°C) | Indoor Ambient Temperature 75°F (24°C) / 63°F (17°C) | Indoor Ambient Temperature 80°F (27°C) / 67°F (19°C) | Indoor Ambient Temperature 90°F (32°C) / 73°F (23°C) |
TC | SC | Input Power | TC | SC | Input Power | TC | SC | Input Power | TC | SC | Input Power |
-.4°F (-18°C) | 10,850 | 8,510 | 700 | 12,230 | 9,600 | 740 | 12,930 | 10,140 | 770 | 14,570 | 11,430 | 820 |
5°F (-15°C) | 11,120 | 8,720 | 700 | 12,550 | 9,840 | 750 | 13,420 | 10,530 | 770 | 14,940 | 11,720 | 820 |
14°F (-10°C) | 11,480 | 9,010 | 720 | 12,950 | 10,160 | 760 | 13,690 | 10,740 | 790 | 15,430 | 12,100 | 850 |
23°F (-5°C) | 12,580 | 9,870 | 720 | 14,330 | 11,240 | 760 | 15,420 | 12,090 | 790 | 16,960 | 13,300 | 840 |
32°F (0°C) | 13,226 | 10,375 | 719 | 15,064 | 11,814 | 763 | 15,489 | 12,143 | 789 | 17,829 | 13,989 | 841 |
41°F (5°C) | 13,905 | 10,907 | 756 | 15,836 | 12,419 | 802 | 16,283 | 12,766 | 829 | 18,743 | 14,707 | 884 |
50°F (10°C) | 14,484 | 11,361 | 788 | 16,496 | 12,937 | 835 | 16,961 | 13,298 | 864 | 19,524 | 15,319 | 921 |
59°F (15°C) | 15,260 | 11,970 | 830 | 17,380 | 13,630 | 880 | 17,870 | 14,010 | 910 | 20,570 | 16,140 | 970 |
68°F (20°C) | 17,281 | 13,553 | 1,221 | 18,361 | 14,398 | 1,260 | 19,621 | 15,389 | 1,337 | 22,501 | 17,650 | 1,430 |
77°F (25°C) | 17,077 | 13,395 | 1,254 | 18,163 | 14,246 | 1,293 | 19,441 | 15,249 | 1,375 | 22,321 | 17,504 | 1,474 |
86°F (30°C) | 16,235 | 12,733 | 1,403 | 17,317 | 13,584 | 1,447 | 18,901 | 14,824 | 1,535 | 21,631 | 16,963 | 1,645 |
95°F (35°C) | 15,367 | 12,052 | 1,507 | 16,441 | 12,891 | 1,551 | 18,001 | 14,119 | 1,650 | 20,719 | 16,252 | 1,766 |
104°F (40°C) | 14,623 | 11,469 | 1,557 | 15,691 | 12,307 | 1,606 | 17,533 | 13,754 | 1,705 | 19,975 | 15,662 | 1,826 |
113°F (45°C) | 13,873 | 10,879 | 1,590 | 14,941 | 11,718 | 1,639 | 16,789 | 13,164 | 1,744 | 19,225 | 15,079 | 1,865 |
118°F (48°C) | 13,501 | 10,587 | 1,606 | 14,401 | 11,292 | 1,656 | 16,201 | 12,709 | 1,760 | 18,541 | 14,544 | 1,881 |
Heating Performance
(Values in BtuH for TC, Watts for Input Power, COP)
Outdoor Ambient Temperature (DB) | Indoor Ambient Temperature 70°F (21°C) / 59°F (15°C) | Indoor Ambient Temperature 75°F (24°C) / 63°F (17°C) | Indoor Ambient Temperature 80°F (27°C) / 67°F (19°C) | Indoor Ambient Temperature 90°F (32°C) / 73°F (23°C) |
TC | SC | Input Power | COP | TC | SC | Input Power | COP | TC | SC | Input Power | COP | TC | SC | Input Power | COP |
-5°F (-21°C) | 10,865 | 1,061 | 3.00 | 10,656 | 1,087 | 2.87 | 10,325 | 1,112 | 2.72 | 9,968 | 1,146 | 2.55 |
0°F (-18°C) | 11,121 | 1,095 | 2.98 | 10,800 | 1,117 | 2.83 | 10,598 | 1,158 | 2.68 | 10,319 | 1,185 | 2.55 |
5°F (-15°C) | 11,428 | 1,119 | 2.99 | 11,099 | 1,142 | 2.85 | 10,891 | 1,184 | 2.69 | 10,606 | 1,212 | 2.56 |
7°F (-14°C) | 11,736 | 1,144 | 3.01 | 11,397 | 1,167 | 2.86 | 11,184 | 1,210 | 2.71 | 10,893 | 1,238 | 2.58 |
17°F (-8°C) | 12,597 | 1,193 | 3.09 | 12,229 | 1,217 | 2.94 | 11,997 | 1,262 | 2.78 | 11,683 | 1,291 | 2.65 |
28°F (-2°C) | 14,230 | 1,271 | 3.28 | 13,856 | 1,297 | 3.13 | 13,458 | 1,345 | 2.93 | 13,298 | 1,376 | 2.83 |
38°F (3°C) | 17,693 | 1,463 | 3.54 | 17,319 | 1,492 | 3.40 | 16,927 | 1,548 | 3.20 | 16,761 | 1,583 | 3.10 |
47°F (8°C) | 19,997 | 1,522 | 3.85 | 19,392 | 1,553 | 3.66 | 19,006 | 1,610 | 3.46 | 18,483 | 1,647 | 3.29 |
57°F (14°C) | 20,657 | 1,551 | 3.90 | 20,033 | 1,583 | 3.71 | 19,635 | 1,641 | 3.50 | 19,089 | 1,679 | 3.33 |
68°F (20°C) | 21,490 | 1,600 | 3.93 | 20,840 | 1,640 | 3.72 | 20,430 | 1,700 | 3.52 | 19,860 | 1,740 | 3.34 |
77°F (25°C) | 21,990 | 1,640 | 3.93 | 21,330 | 1,680 | 3.72 | 20,900 | 1,740 | 3.52 | 20,320 | 1,780 | 3.34 |
LEGEND:
DB - Dry Bulb
WB - Wet Bulb
TC - Total Capacity (BtuH)
SC - Sensible Capacity (BtuH)
Input Power - (Watts)
COP - Coefficient Of Performance
Certifications: AHRI Certified, ETL Listed.
Specifications are subject to change without notice. Manufacturer reserves the right to discontinue or modify specifications or designs without notice or without incurring obligations. All rights reserved.