LG R32 Multi F MAX with LGRED° Outdoor Unit
Model: KUMXA481A
Performance Specifications
Parameter | Value |
---|---|
Cooling Capacity (Min.-Rated-Max., Btu/h) | 10,800~48,000~58,000 |
Heating Capacity (Min.-Rated-Max., Btu/h) | 12,420~52,500~59,000 |
Max. Heating Capacity at 17°F (Btu/h) | 56,500 |
Max. Heating Capacity at 5°F (Btu/h) | 52,500 |
Max. Heating Capacity at -4°F (Btu/h) | 45,200 |
Max. Heating Capacity at -13°F (Btu/h) | 39,200 |
Cooling COP @95°F (Rated) | 3.84 |
Heating COP @47°F (Rated) | 3.62 |
Cooling Nominal Test Conditions | Indoor: 80°F DB / 67°F WB; Outdoor: 95°F DB / 75°F WB |
Heating Nominal Test Conditions | Indoor: 70°F DB / 60°F WB; Outdoor: 47°F DB / 43°F WB |
Electrical Specifications
Parameter | Value |
---|---|
Power Supply (V/Hz/Ø) | 208-230V, 60, 1 |
MOP (A) | 40 |
MCA (A) | 33.3 |
Cooling Rated Amps (A) | 24.30 |
Heating Rated Amps (A) | 24.30 |
Compressor (A) | 23.0 |
Fan Motor (A) | 1.30 |
Locked Rotor Amps (A) | 22 |
Piping Specifications
Parameter | Value |
---|---|
Refrigerant Charge (lbs.) | 9.262 |
Liquid Line Connection (in., O.D.) | Ø3/8 x 1 |
Vapor Line Connection (in., O.D.) | Ø3/4 x 1 |
Maximum Total Piping³ (ft.) | 475.7 |
Min. / Max. ODU to IDU Piping (ft.) | 32.8/229.6 |
Piping Lengths (no add'l refrigerant, ft.) | 180.4 |
Additional Refrigerant Charge Main Pipe (oz. / ft.) | 0.54 |
Additional Refrigerant Charge Branch Pipe (oz. / ft.) | 0.22 |
Maximum Elevation between ODU and IDU (ft.) | 98.4 |
Maximum Elevation between IDU and IDU (ft.) | 49.2 |
Operating Range
Parameter | Value |
---|---|
Cooling (°F DB) | 14 to 118 |
Heating (°F WB) | -13 to +64 |
Unit Data
Parameter | Value |
---|---|
Refrigerant Type | R32 |
Refrigerant Control | EEV |
Sound Pressure (Cool / Heat) ±1 dB(A)¹ | 54/56 |
Net / Shipping Weight (lbs.) | 218.3/239.2 |
Power Wiring: ODU→BDU, BDU→IDU (No x AWG) | 3 x 14, 3 x 14 |
Comm. Wiring: ODU→BDU, BDU→IDU (No x AWG) | 2 x 18, 2 x 18 |
Heat Exchanger Coating | Gold Fin™ |
Minimum No. of Indoor Units | 2 |
Maximum No. of Indoor Units | 8 |
Compressor
Parameter | Value |
---|---|
Type | Scroll |
Quantity | 1 |
Oil / Type | PVE |
Fan
Parameter | Value |
---|---|
Type | Propeller |
Quantity | 2 |
Motor / Drive | Brushless Digitally Controlled/Direct |
Max. Airflow Rate (CFM) | 2,119 x 2 |
Features
- Scroll (Variable Speed) Compressor
- Auto operation / Auto restart
- Integrated central control connection
- Self diagnosis / Soft start
- Defrost / Deicing
- Low ambient cooling down to 14°F (-4°F with Wind Baffle Kit)
- Restart delay (three [3] minutes)
- Factory installed Drain Pan Heater
Piping System Limitations
Parameter | Value |
---|---|
Total piping length (ΣΑ + ΣΒ) | <475.7 feet |
Main pipe (Outdoor Unit to Branch Distribution Units: A) | Minimum: 16.4 feet; Maximum (ΣΑ): <180.4 feet |
Total branch piping length (ΣΒ) | <295.3 feet |
Branch pipe (Branch Distribution Units to Indoor Units: B) | Minimum: 16.4 feet; Maximum: <49.2 feet |
Elevation Differential (All Elevation Limitations are Measured in Actual Feet) | If outdoor unit is above or below indoor unit (h1): <98.4 feet Between the farthest two indoor units (h2): <49.2 feet Between branch distribution unit and farthest connected indoor unit(s) (h3): <32.8 feet Between branch distribution units (h4): <49.2 feet |
Piping Sizes
Piping | Main Pipe A (inch) | Branch Pipe B |
---|---|---|
Liquid | Ø3/8 | Depends on the size of the indoor unit piping. |
Vapor | Ø3/4 | Depends on the size of the indoor unit piping. |
Required Accessories
- 2-Port BD Unit - PMBD3620ZR
- 3-Port BD Unit - PMBD3630ZR
- 4-Port BD Units - PMBD3640ZR / PMBD3641ZR
Optional Accessories
- Power Distribution Indicator (PDI) Premium - PQNUD1S41
- Mobile LGMV for Android® Smartphones / Tablets or for iOS® Tablets - PLGMVW100
- LG Monitoring View (LGMV) for Computers - PRCTILO
- Low Ambient Wind Baffle Kit - ZLABGP04A x 2
Controller Options
- MultiSITE Communication Mgr.
- AC Smart 5
- ACP 5
- ACP 5 BACnet® Gateway
- LonWorks® Gateway
Certifications and Compliance
The LG R32 Multi F MAX system is designed to meet ENERGY STAR® criteria when properly matched with appropriate components. It is also AHRI CERTIFIED® under Standard 210/240 for Unitary Small HP.
Note: Proper sizing and installation of equipment are critical for optimal performance. For details, consult your contractor or visit www.energystar.gov.
General Notes
- Acceptable operating voltage: 187V - 253V.
- All power supply wiring to the ODU is field supplied, solid or stranded. The power wiring and the communication wiring from the ODU to the BDU, and from the BDU to the IDU is field supplied and must be stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the ODU only). All wiring must comply with applicable local and national codes.
- Piping lengths are equivalent.
- For continual product development, LG reserves the right to change specifications without notice.
- Must follow installation instructions in the applicable LG installation manual.
File Info : application/pdf, 3 Pages, 2.30MB
DocumentDocumentReferences
Adobe InDesign 20.0 (Windows) Adobe PDF Library 17.0; modified using iTextSharp 4.1.6 by 1T3XTRelated Documents
![]() |
LG KUMXA301A R32 Multi F LGRED Outdoor Unit Specifications Technical specifications and performance data for the LG KUMXA301A R32 Multi F LGRED Outdoor Unit, including cooling and heating capacities, electrical requirements, piping details, and operational features. |
![]() |
LG Multi F & Multi F MAX with LGRED° Outdoor Unit Engineering Manual Comprehensive engineering manual for LG's Multi F and Multi F MAX with LGRED° outdoor units, detailing system design, selection procedures, and technical specifications for R32 refrigerant. |
![]() |
LG KUMXA241A R32 Multi F Outdoor Unit: Technical Specifications and Features Detailed technical specifications, performance data, features, and installation notes for the LG KUMXA241A R32 Multi F with LGRED° outdoor HVAC unit, including operating ranges, electrical requirements, piping details, and unit data. |
![]() |
LG KUMXA181A R32 Multi F LGRED° Outdoor Unit Technical Specifications Detailed technical specifications for the LG KUMXA181A R32 Multi F LGRED° Outdoor Unit, including performance data, operating ranges, electrical and piping requirements, features, and dimensions. Suitable for split system HVAC applications. |
![]() |
LG KUMXA361A R32 Multi F MAX Outdoor Unit Technical Specifications Detailed technical specifications for the LG KUMXA361A R32 Multi F MAX outdoor unit, including performance data, electrical requirements, piping limitations, and dimensions. Suitable for HVAC professionals and system designers. |
![]() |
LG Multi F / Multi F MAX Outdoor Unit Installation Manual Comprehensive installation guide for LG's Multi F and Multi F MAX multi-zone heat pump systems. Covers outdoor unit installation, safety, electrical, and piping requirements for efficient HVAC solutions. Visit www.lghvac.com for more resources. |
![]() |
LG KUMXB241A R32 Multi F Outdoor Unit Technical Specifications Comprehensive technical datasheet for the LG KUMXB241A R32 Multi F Outdoor Unit, detailing performance, electrical, piping, features, and operating parameters for HVAC installations. |
![]() |
LG KSSLA421A R32 Single Zone LGRED™ Multi-Position Air Handling Unit Specifications Detailed specifications for the LG KSSLA421A R32 Single Zone LGRED™ Multi-Position Air Handling Unit, including performance, operating ranges, electrical, piping, and system data. Features include Inverter compressor, GoldFin™ heat exchanger, and various control options. |