User Manual for ARMEATOR models including: A101, A101 One Smart Wireless Meat Thermometer, One Smart Wireless Meat Thermometer, Smart Wireless Meat Thermometer, Wireless Meat Thermometer, Meat Thermometer, Thermometer

单针1.0说明书-518 复制

USER MANUAL ARMEATOR ONE

13 ore fa — Bluetooth connection. Ceramic ... Take the probe out of the dock and click the. Dock Power Button for pairing. ... Bluetooth LE 5.2 wireless connection. 72 hours of ...

1 day ago — USER MANUAL. SMART WIRELESS. MEAT THERMOMETER. A101. ARMEATOR ONE. Page 2. Get to know the device. Rubber mat with magnet. Dock lock. Battery cover. AAA *2 ...

Wildaven MSWK204 Use and Care Manual

Digital Remote Bluetooth Compatibility Meat Thermometer 826764127674

PDF preview unavailable. Download the PDF instead.

66872328
ARMEATOR ONE USER MANUAL
SMART WIRELESS
MEAT THERMOMETER
A101

Get to know the device
Rubber mat with magnet

EN

Dock lock

Battery cover AAA *2 battery

2*AAA size batteries are needed for this charging case. Make sure they are put in the right direction on the unit.
Wireless frequency range: 2400MHz-2483.5MHz Average current: 2.4V/22uA Max wireless transmission power: 2.5dbm

LED
SUS304 Charging Food Safety electrode`+'

Charging electrode`-'
Ceramic handle

Sensor

Dock charging electrode

Bluetooth connection
Dock Power status Light on: Sufficient power
Light not on: No power *To check the dock power, you need to press the button.
How to charge the probe The probe will automatically charge when placed in the dock.

Download the APP

Search the keyword `ARmeator' in Appstore or Google Play, or scan the following QR code with your phone. Download and install it for free.
Make sure your phone meets the requirements:

iOS devices running version 11.0 or later.
Android devices running version 5.0 or later with blue-tooth 4.0 module or later.

APP DOWNLOAD

Pair with your phone
 Take the probe out of the dock and click the Dock Power Button for pairing.
If it has not been used for a long time, please charge the probe first to ensure sufficient power.  keep the blue-tooth switch of your phone on.
 Launch the "ARMEATOR" app.  Follow the instructions in the app.  Choose the Armeator device you want to add. Once dock is paired with your phone, you don't need to do it again, unless you change to other phones.
Connected successfully

HOW TO USE Insert the probe
Keep the safety line covered by the meat
Insert the probe into the thickest part of the meat, and ensure the notch on the probe is fully covered by the meat while the tip of the probe is inside the meat. Notes: If you wrap your meat in aluminum foil, you must puncture the probe into the meat through the foil. lf you wrap the probe and meat in foil, the probe will lose connectivity.
Start a New Cook
Choose food type and preference for the food where each probe is inserted, the app and the device will display its current and target temperature. When the food is ready, the app will alarm you.
* The user interface of the app may be changed when upgraded. Please follow the instructions in the app.

WARNING
The heat resistance varies in different components of the probe DO NOT put the probe needle part directly in fire flame. And probes are NOT dishwasher safe. Kindly avoid submerging the probe in any liquid.
Please clean the probe each time you use it to make sure there is no dust and oil on the charging electrode.
Ceramic handle withstands heat up to 500C/932 F
Charging electrode`-'
Charging electrode `+'
Safety line

This part must be inserted into the meat to protect electronic components.

Sensor
Measurement range 0~100°C/32~212°F Accuracy ±0.5°C(±0.9°F)

App Store is a service mark of Apple Inc. Google Play is a service mark of Google Inc.

SPECIFICATIONS

Probe to Dock Wireless Range 70m / 229 ft

(Unobstructed)

Dock to Phone Wireless Range 70m / 229ft

(Unobstructed)

Probe to Dock Wireless Range 10m / 32ft

(Close the oven lid)

Bluetooth

Bluetooth LE 5.2 wireless connection

Probe Working Time

72 hours of continuous cooking

Ceremic Handle

500 / 932 (can be used in flames)

Probe Temp.Range

0~100 / 32~212 (meat)

Measurement Error

±0.5 / ±0.9°F

Water-Resistence

IP65

Probe Material

SUS304 Stainless Steel (Food Safety) & Ceramic

Magnetic Backing

Built-in magnet

Battery

AAA*2

Charging Time

15 min

Probe Diameter

5.5mm / 0.22in

Probe Size

129*15*15mm / 5.08*0.59*0.59in

Charging Dock Size

47*140*27.5mm / 1.85*5.51*1.08in

App Requirement

iPhone and iPad apps for iOS 11 and later

Android app for versions 5.0 and later

FCC Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
15.21 Information to user.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
15.105 Information to the user.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interfer-ence to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
7


Adobe PDF library 16.00 Adobe Illustrator(R) 24.0