User Manual for nvent raychem models including: ETS-05 EAC Electronic thermostat, Electronic thermostat
Электронный термостат ETS-05 | nVent
ETS-05 Electronic Thermostat | nVent
File Info : application/pdf, 20 Pages, 1.12MB
DocumentDocumentETS-05 (EAC) Electronic thermostat Ti A 3 mm 7 mm 33 mm (M25) 19 mm (M16) 10 mm THERMOSTAT TERMINAL B 23 23 1 0 901 901 1 78 78 456 456 0 E F C D A B A Thermostat enclosure / B Cable entries (2 x M25, 1 x M20 + 1 x M16) / C Temperature sensor terminals / D Power and Heat Tracing Terminal blocks (max. 6 mm2) / (. 6 2) E Alarm Relay / F Temperature setting dials / 2 | nVent.com/RAYCHEM WIRING C MAX 32 AMP 30 mA Alarm C Relay 12 3 NN L1 out L1 in A B Power Sensor Terminals Terminals ETS-05 PPP EEE 12 34 Fail-Safe option E Link 3-4 removed = output OFF Link 3-4 fitted= output ON F Heating D Cable A Power Terminals / B Sensor Terminals / C Alarm Relay / D Heating cable / E Link 3-4 removed = output OFF / 3-4 = . F Link 3-4 connected= output ON / 3-4 = . nVent.com/RAYCHEM | 3 ETS-05 (EAC) ATEX Baseefa13ATEX0137 II 2(1)G Ex eb ia mb [ia Ga] IIC T5 Gb -40°C Ta +60°C II 2D Ex tb IIIC T100°C Db IECEx BAS 13.0071 Ex eb ia mb [ia Ga] IIC T5 Gb (-40°C Ta +60°C) Ex tb IIIC T100°C Db (-40°C Ta +60°C) All ETS-05 version marked with (EAC) have the following EAC Ex certification*: RU C-BE.A58.B.02648/22 «» 1Ex e ia mb [ia Ga] IIC T5 Gb Ex tb IIIC T100°C Db IP66 60°C Ta 60°C * ETS-05 EAC EAC Ex. 4 | nVent.com/RAYCHEM ENGLISH VERSIONS ETS-05 The ETS-05 is available in the following versions: ETS-05-AB-CD-E Letters ABCDE described in table below Type Description ETS-05 "A": Setpoint Range A: Ambient Sensing L: Line sensing, Low Temp H: Line Sensing, High Temp. 0°C to 49°C 0°C to 199°C 0°C to 499°C "B" Voltage Range 1: 110 Vac 1R: 110 Vac 2: 230 Vac 2R: 277 Vac 99-121 Vac 99-132 Vac 195-230 Vac +10% 195-277 Vac + 3% "C" E: ATEX / IECEx approved (IEC countries) J: ATEX / IECEx approved (for Japan) "D" P: Earth plate "E" A: Alarm Relay NO and NC contacts Temperature Measurement Range -65°C to 260°C -65°C to 260°C -65°C to 585°C 275 Vac, 3A resistive load max Examples: · ETS-05-L2-EP: ETS-05 thermostat, setpoint range 0-199°C, 195-230 Vac, ATEX/IECEx approved, Earth Plate · ETS-05-H2R-EP-A: ETS-05 thermostat, setpoint range 0-499°C, 195-277 Vac, ATEX/IECEx, Earth Plate, Alarm Relay IMPORTANT: The ETS-05 for EAC countries does not include a sensor. The sensor needs to be purchased seperately. nVent.com/RAYCHEM | 5 THERMOSTAT TERMINALS AND WIRING Diagram: page 3 1 Power terminals 1 2 3 4 5 Line Neutral Neutral 230V Earth Out Out Supply Supply 6 Earth 7 Earth · Terminals 2 and 3 are joined electrically · Terminals 5, 6 and 7 are joined electrically Note: Do not remove Earth connecting wire. 2 Sensor/Failure mode select terminals 1 234 Link 3-4 removed = Output OFF Link 3-4 connected= Output ON · Terminals 1 to 3 allow for the connection of a three wire sensor. · Terminals 3 to 4 allow the user to select the default heating status on sensor error: Without a link fitted the heating will turn OFF if a sensor error is detected (default) With a link fitted the heating will turn ON if a sensor error is detected 3 Alarm relay · Healthy situation: 1-3 is closed, 2-3 is open · Alarm situation: 1-3 is open, 2-3 is closed 12 3 4 Voltage and current rating Maximum switch current 32 A resistive Um = 253 Vac for all versions except Extended Voltage Range Um = 277 Vac for all other versions Note: Only Ex eb and Ex tb equipment certified cable glands or stopping plugs which employ a sealing washer or gasket may be used. 6 | nVent.com/RAYCHEM INSTALLATION INSTRUCTIONS THERMOSTAT 1. Instructions on the use of the equipment and safety measures · Do not connect/disconnect equipment unless power has been switched off or the area is known to be non-hazardous. · Follow all applicable wiring codes and regulations. · Peripheral equipment must be suitable for the location in which it is used. · Only technically qualified service personnel are permitted to install or service the equipment. Only to be installed in hazardous area by trained electrical installer with basic knowledge about explosion safety. · Do not disassemble the system - no user-serviceable parts inside. · Do not operate the equipment if it has been damaged 2 Enclosure installation ETS-05 line-sensing thermostat Alternative mounting arrangements are shown above (4 mounting holes, M6 clearance at 106 x 82 mm). For optimized temperature control install the unit remote from sensor bulb. Locate enclosure at appropriate place to avoid exposure to mechanical and thermal damage (do not mount on pipe for high temperatures). WARNING: When working in damp or wet conditions protect the thermostat contents from water ingress, by closing lid when not working on the assembly. 3 Enclosure installation ETS-05-A2-E (ambient sensing thermostat) TEElTheeScr-tm0ro5on-Asict2a-HtEeat-Tracing For optimized temperature control locate the thermostat: · As indicated in the system design documentation · So that the sensor is exposed to the coldest conditions · So that the sensor is not exposed to direct sunlight where possible · So that the sensor is exposed to the strongest wind · To ensure that no snow can build up around the sensor · To avoid exposure to mechanical and thermal damage nVent.com/RAYCHEM | 7 4 Location of the sensor ETS-05 ETSE-l0eT5cht-Lreo2rmn-EicosHtaeat t-Tracing A B 90° C · As indicated in the system design documentation · Away from valves, flanges, supports, pumps, or other heat sinks · At the top of the pipe for thermally sensitive pipe contents (A) · On lower quadrant of pipe 90° for single heating cable (B) · On lower quadrant of pipe centrally between the heating cables if they are two or more (C) 5 Attachment of the sensor ETS-05 WARNING: Do not install sensor at ambient temperatures below 20°C. Do not bend sensor (last 50 mm), keep it straight under all circumstances. Minimum bending radius for High Temperature Mineral Insulated Sensor extension cable is 20 mm. 20 mm D ETSE-l0eT5cht-Lreo2rmn-EicosHtaeat t-Tracing 1. Fix sensor firmly on surface with adequate fixing tape in two places (D) 2. Fix sensor parallel to pipe (D) 3. Route extension cable to avoid damage in use. Fix to pipe with adequate tape where appropriate 8 | nVent.com/RAYCHEM 6 Complete installation ETS-05 Ensure that the pipe and sensor are thermally insulated and clad to the design specification after installation of thermostat. Seal cladding with sealant (A). When thermostat installation is complete, test as described in the Testing & Commissioning Section. Retain this instruction for future use, e.g. setting, testing, maintenance etc. 7 Temperature setting dials If necessary, loosen lid screws and remove lid. Adjust digital switches to switching temperature (°C). The switches present the setpoint temperature in three digits (100, 10, 1). Locate lid and tighten lid screws. WARNING: Ensure thermostat is isolated elsewhere for a minimum of 1 minute before opening. High Temperature version 0°C - 499°C 401 901 901 78 78 23 23 23 23 456 456 401 Low Temperature version 0°C - 199°C 0 901 901 78 78 1 23 23 1 456 456 0 Ambient version 0°C - 49°C 401 901 78 23 23 23 456 401 nVent.com/RAYCHEM | 9 8 Testing, commissioning, and maintenance Test heating cable when thermostat installation is complete as directed in nVent Installation and Maintenance manual. Maintain thermostat during normal plant maintenance. CHECK: · Mounting is firm · Exposed extension cable is not damaged · Gland sealing washer is in place · Gland seal (grommet) is in place · Gland body and nut(s) are tightened firmly · Thermostat operation is correct · Thermostat setting suites application · Lid is closed firmly · Earth wire connecting Earth stud to terminal block Earth is present and secure · Cable type is correct (Insulation >255V and temperature rating to suit application) Note: Cable gland heat-rise could reach 30K · Not more than one conductor may be connected into power terminal block without the use of a single insulated bootlace ferrule 10 | nVent.com/RAYCHEM ETS-05 ETS-05 : ETS-05-AB-CD-E ABCDE ETS-05 "A": A: L: , H: , . 0°C - 49°C 0°C - 199°C 0°C - 499°C -65°C - 260°C -65°C - 260°C -65°C - 585°C "B" 1: 110 . 1R: 110 . 2: 230 . 2R: 277 . 99-121 . 99-132 . 195-230 . + 10% 195-277 . + 3% "C" E: ATEX / IECEx ( IEC) J: ATEX / IECEx ( ) "D" P: "E" A: 275 . , . 3 : · ETS-05-L2-EP: ETS-05, 0-199°C, 195-230 . , ATEX / IECEx, · ETS-05-H2R-EP-A: ETS-05, 0-499°C, 195-277 . , ATEX / IECEx, , ! ETS-05 EAC . . nVent.com/RAYCHEM | 11 : . . 3 1 1 2 3 4 230 5 6 7 · 2 3 · 5, 6 7 . 2 / 1 234 3-4 = . 3-4 = . · 1 3 . · 3 4 , : , ( ). , . 3 · : 1-3 , 2-3 · : 1-3 , 2-3 12 3 4 . 32A, Um = 253 . , . Um = 277 . : «Ex eb» «Ex tb» . 12 | nVent.com/RAYCHEM 1. · l/ . · l . · l . · l . , . · l . . · l , . 2 ETS-05 ( ) (4 , M6 106 x 82 ). . , ( ). ! : , . 3 ETS-05-A2-E ( ) TEElTheeScr-tm0ro5on-Asict2a-HtEeat-Tracing : · C · , · , · , ; · , · , nVent.com/RAYCHEM | 13 4 ETS-05 ETSE-l0eT5cht-Lreo2rmn-EicosHtaeat t-Tracing A B 90° C · C · , , , · , () · , 90° (B) · , , (C) 5 ETS-05 ! 20°C. ( 50 ), . 20 . 20 mm D ETSE-l0eT5cht-Lreo2rmn-EicosHtaeat t-Tracing 1. (D) 2. (D) 3. . , 14 | nVent.com/RAYCHEM 6 ETS-05 . , (A). « ». : , , , . 7 . (°C). (100, 10, 1) . ! 1 , . 0°C - 499°C 401 901 901 78 78 23 23 23 23 456 456 401 0°C - 199°C 0 901 901 78 78 1 23 23 1 456 456 0 0°C - 49°C 401 901 78 23 23 23 456 401 nVent.com/RAYCHEM | 15 8 , nVent. . : · · · ; · ( ) · () · · C ; · ; · , . · ( >255 , ). : 30K · 16 | nVent.com/RAYCHEM nVent.com/RAYCHEM | 17 18 | nVent.com/RAYCHEM nVent.com/RAYCHEM | 19 België / Belgique Tel. +32 16 21 35 02 Fax +32 16 21 36 04 salesbelux@nVent.com Bulgaria Tel. +359 5686 6886 Fax +359 5686 6886 salesee@nVent.com Ceská Republika Tel. +420 602 232 969 czechinfo@nVent.com Denmark Tel. +45 70 11 04 00 salesdk@nVent.com Deutschland Tel. 0800 1818205 Fax 0800 1818204 salesde@nVent.com España Tel. +34 911 59 30 60 Fax +34 900 98 32 64 ntm-sales-es@nVent.com France Tél. 0800 906045 Fax 0800 906003 salesfr@nVent.com Hrvatska Tel. +385 1 605 01 88 Fax +385 1 605 01 88 salesee@nVent.com Italia Tel. +39 02 577 61 51 Fax +39 02 577 61 55 28 salesit@nVent.com Lietuva/Latvija/Eesti Tel. +370 5 2136633 Fax +370 5 2330084 info.baltic@nVent.com Magyarország Tel. +36 1 253 7617 Fax +36 1 253 7618 saleshu@nVent.com Nederland Tel. 0800 0224978 Fax 0800 0224993 salesnl@nVent.com Norge Tel. +47 66 81 79 90 salesno@nVent.com Österreich Tel. 0800 29 74 10 Fax 0800 29 74 09 salesat@nVent.com Polska Tel. +48 22 331 29 50 Fax +48 22 331 29 51 salesee@nVent.com Republic of Kazakhstan Tel. +7 712232 09 68 Fax +7 7122 32 55 54 saleskz@nVent.com . +7 495 926 18 85 +97 495 926 18 86 salesru@nVent.com Serbia and Montenegro Tel. +381 230 401 770 Fax +381 230 401 770 salesee@nVent.com Schweiz / Suisse Tel. +41 (41) 766 30 80 Fax +41 (41) 766 30 81 infoBaar@nVent.com Suomi Puh. 0800 11 67 99 salesfi@nVent.com Sverige Tel. +46 31 335 58 00 salesse@nVent.com Türkiye Tel. +90 560 977 6467 Fax +32 16 21 36 04 salesee@nVent.com United Kingdom Tel. 0800 969 013 Fax 0800 968 624 salesthermalUK@nVent.com nVent.com/RAYCHEM ©2022 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. RAYCHEM-IM-EU2012-ETS05EAC-ML-2205