Instructions for logico2 models including: 0475 Enrichment Valve 10W, 0475, Enrichment Valve 10W
enrichment valve 0475 en in hfe1216 r2 0 - Logico2
File Info : application/pdf, 4 Pages, 492.77KB
DocumentDocumentInstallation Instruction 0475 Enrichment Valve 10W ENGLISH Enrichment Valve with filter for Grow CO2 Enrichment Controller. Important! Retain this instruction manual for future reference: Please read these instructions carefully prior to start-up and use. Failure to follow any of these instructions could void product warranties. LogiCO2 assumes no responsibility for claims arising out of improper or careless use or handling of their products. Function Enrichment Valve is an accessory for LogiCO2 Grow CO2 Enrichment Controller. The Grow CO2 Enrichment Controller is a device that measures the concentration of CO2 in the ambient environment of the room being controlled and opens/closes the dispenser valve, to achieve a perfect CO2 environment in the grow room. Enrichment Valve consists of a magnetic valve with filter, electronics box and cabling. The Enrichment Valve is designed for usage of CO2 with a pressure of 0,15 to 30 bar or 2,2 to 435 Psi. Enrichment Valve has a 1 meter Cat5 cable from the electronics box, with a blue RJ45 connector that is plugged in to the blue cable side of the Grow CO2 Enrichment Controller. Install the electronics box in a suitable place where it is mechanically protected. Remove the cover by turning it counterclockwise 1/8 turn to access the mounting screw holes. Technical specifications Power supply: Via Grow CO2 Enrichment Controller Power consumption: 420 mA (10 Watt) Relays: 1A/24V AC/DC Material: PC/ABS Operating pressure: 0,15 to 30 bar / 2,2 to 435 Psi Bursting pressure: >150 bar / 2 175 Psi Treaded connection: 1/4" -18NPT Dimensions (WxHxD) Connection box: 78x78x37 mm / 3"x3"x1.5" Ingress protection: IP55 Connection diagram This connection diagram shows an example of how the different systems can be installed. Grow CO2 Enrichment Controller CO2 CO2 Grow Certified by UL Ratings: 24Vdc, 68mA Made in Sweden ! LogiCO2 International Changing CO2 target setpoint on Grow CO2 Controller Press the button setpoint. to adjust the CO2 target The setpoint for the target CO2 concentration is adjustable from 700 to 2000 ppm in steps of 50 ppm. The default setpoint is 1200 ppm. Setpoint "OFF" stops the CO2 regulation. The display is alternately reading: · The current CO2 concentration · The CO2 target setpoint value · The altitude setting (height over the ocean) LED indications on the Grow CO2 Controller: · Red: Alarm - CO2 concentration over 5000 ppm · Green: Adding CO2 gas · Green: Power on For complete instructions and settings, please see the user manual for Grow CO2 Controller. Pat. Pend. RJ45 Splitter (blue) 1-1/1-2/1-4 0475 Enrichment Valve 0471 RCB for fan control SIGN GROW EN R1.0 SIGN C-U MK9 EN 0021 Power Supply 0328 Mk9 Central Unit Gas Monitor Central Unit LogiCO2 Certified by UL Ratings: 24Vdc, 32mA Made in Sweden Mk9 ! CO2 Safety System - Mk9 What to do in case of an ALARM? 1. Keep Calm! 2. Turn off the sounding alarm on the Central Unit by pressing the RESET button on the front. 3. Check the type of alarm and which Sensor is giving the alarm by following the instructions below. INDICATION Central Unit: · The red diode is ON · Constant sound signal Display: · Sensor number, alternating ALARM and CO2 % Central Unit: · The red diode is blinking · Beeping sound signal Display: · Sensor number, alternating ALARM and CO2 % Central Unit: · The red diode is blinking · Beeping sound signal Display: · Sensor number, alternating ALARM and CO2 ppm value CO2-Sensor: · Beeping sound signal every 5 seconds Display: · High and CO2 % Central Unit: · The yellow diode is blinking · Beeping sound signal Display: · Sensor number, (Fault information) After an alarm, always reset the system. To insure that communication, warning lamps and sounders function. CAUSE ACTION HIGH-ALARM ! TAKE PRECAUTIONS High concentration of CO2 DO NOT ENTER the risk zone. Evacuate the area. Call the fire department. LOW-ALARM High concentration of CO2 A service technician should only enter the room under the supervision of another person. Open the doors and the windows as much as possible. TWA-ALARM There is a small CO2 leak that has lasted for over 8 hours CO2 AWARENESS INDICATION Open the doors and the windows as much as possible. Find and stop the leakage, if not found, call service. Phone: .................................. Be aware that the CO2 concentration is over 5000 ppm. There is no danger. SYSTEM FAULT ALARM RESET ALARM TEST Check the manual, communication cables and CO2-Sensor. If no fault is found, call service. Phone: .................................. Press reset button until "Alarm cleared!" is shown in the display. Press reset button until "Testing system..." is shown in the display. Sensor 1 2 3 4 5 6 7 8 Place RJ45 Splitter (red) 1-1/1-2/1-4 0482 Power Barrier CO2 CO2 Grow Certified by UL Ratings: 24Vdc, 68mA Made in Sweden ! LogiCO2 International CO2 Sensor CO2 LogiCO2 Mk9 Certified by UL Ratings: 24Vdc, 68mA Made in Sweden DIN Reg. No: 6L002 ! CO2 Sensor CO2 LogiCO2 Mk90 Certified by UL Ratings: 24Vdc, 117mA Made in Sweden DIN Reg. No: 6L002 ! CO2 CO2 Grow Certified by UL Ratings: 24Vdc, 68mA Made in Sweden ! LogiCO2 International CO2 Sensor CO2 LogiCO2 Mk9 Certified by UL Ratings: 24Vdc, 68mA Made in Sweden DIN Reg. No: 6L002 ! CO2 Sensor CO2 LogiCO2 Mk90 Certified by UL Ratings: 24Vdc, 117mA Made in Sweden DIN Reg. No: 6L002 ! Possibility to expand with up to twelve Grow CO2 Enrichment Controllers/ Mk9/mk90 CO2 Sensors 2 Annual function control of the Enrichment Valve with filter Instruction on how to clean the filter on the Enrichment Valve Please observe that the flow of CO2 must be turned off manually, by closing the emergency safety valve and verify that there is no gas pressure in the system. This is very important since you are about to open the system to clean the filter. Any debris should be caught inside the filter. By using a socket wrench, carefully remove the filter from the valve and clean it. After cleaning, make sure that the filtergasket is in place and mount the filter again firmly. Carefully open the emergency safety valve to allow the flow of CO2 again. Annual function and installation check of the Enrichment Valve with filter Checklist Enrichment Valve with filter YES NO Is the Enrichment Valve installed on the downside from the emergency safety valve? Does the red diode on the Enrichment Valve turn on and off when the valve is dispensing/ not dispensing CO2 gas? Has the filter on the Enrichment Valve been cleaned? Enrichment Valve installed with filter 3 Manufactured by: LogiCO2 International AB Box 9097 400 92 Gothenburg, Sweden E-mail: info@logico2.com Web: www.logico2.com © 2022-01-10 R2.0 LogiCO2 HFE1216 EN