Installation Guide for MATRIX models including: CATOME, 2ADHNCATOME, ATOM RD300, ATOM RD200, ATOM RD100, ATOM RD200 Access Control Card Reader, Access Control Card Reader, Card Reader, Reader
MATRIX COMSEC PVT. LTD. CATOME COSEC ATOM RD300 2ADHNCATOME 2ADHNCATOME catome
MATRIX COMSEC PVT. LTD. CATOMM COSEC ATOM RD300 2ADHNCATOMM 2ADHNCATOMM catomm
MATRIX COMSEC PVT. LTD. COSECAT3E COSEC ATOM RD100 2ADHNCOSECAT3E 2ADHNCOSECAT3E cosecat3e
File Info : application/pdf, 19 Pages, 1.70MB
DocumentDocumentCOSEC ATOM ATOM RD300 ATOM RD200 ATOM RD100 Quick Installation Guide 123 456 789 *0 # Safety Instructions These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss. Cautions Do not install the device: Y On unstable surface. Y Where ferromagnetic field or noise is induced. Y Where static is created, such as desks made of plastics, carpets. Y Near volatile inflammable materials or inflammable goods such as drapes. Y Where volatile gas and/or inflammable gas is created. Warning Y Installing and servicing should be done only by qualified technician. Y There are no user-serviceable parts inside. Y Opening or removing the device cover may result in electric shock or exposure to other hazards. Y Use the device only for the purpose for which it was designed. Contents Know your ATOM What your Package Contains Things you will Need Installation Technical Specifications LED and Buzzer Indications Connecting the Reader Know your ATOM 4 Y COSEC ATOM is a slave reader which can work with COSEC ARGO, COSEC VEGA, COSEC PATH V2 using RS-232 and with COSEC ARC 6 DC200 using RS-485. It can also work with 3rd party Wiegand Interface. 6 Y It is an intelligent compact Access Control Device which supports 7 Bluetooth and Card Credentials for Access Control and Time & Attendance. 29 Y COSEC ATOM has three main variants that contains either Matrix FP sensor(MF) or Suprema Sensor(SF). The respective variants are 31 listed below, 35 Type 1: COSEC ATOM RD300 Please read this guide first for correct installation and retain it for future reference. The information in this guide is prevailing at the time of publication. However, Matrix Comsec reserves the right to make changes in product design and specifications without prior notice. Copyright All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Matrix Comsec. Warranty Limited Warranty. Valid only if primary protection is provided, mains supply is within limit and protected, and environment conditions maintained within product specifications. Complete warranty statement is available on our website: www.matrixaccesscontrol.com 3 3 1 4 3 25 3 Figure 1: Front View Figure 2: Back View 1. Display Screen 2. Finger Sensor 3. Mounting Screw Hole 4. Cable Assembly 5. Mounting Plate Sub Variants * ATOM RD300SFE * ATOM RD300MFE Y ATOM RD300MFM Y ATOM RD300MFI Y ATOM RD300SFM Y ATOM RD300SFI 4 Type 2: COSEC ATOM RD200 1 3 4 3 25 3 Figure 3: Front View Figure 4: Back View Type 3: COSEC ATOM RD100 13 5 2 3 4 Figure 5: Front View 5 Figure 6: Back View 1. LED Indicator 2. Finger Sensor 3. Mounting Screw Hole 4. Cable Assembly 5. Mounting Plate Sub Variants Y ATOM RD200MFM Y ATOM RD200MFI Y ATOM RD200SFM Y ATOM RD200SFI 1. LED Indicator 2. Numeric Keypad 3. Mounting Screw Hole 4. Cable Assembly 5. Mounting Plate Sub Variants * ATOM RD100KE * ATOM RD100E Y ATOM RD100KM Y ATOM RD100KI Y ATOM RD100M Y ATOM RD100I What your Package Contains Y COSEC ATOM Unit Y Cable Assembly Y Wall Mounting Accessories Y Flush Mounting Accessories (with Type 1 and Type 2 only) Things you will Need Y Power Drill Y Screw Driver Set Y A Wire Striper Y Insulation Tape Y Necessary Cabling Y Wiegand supported device Y Access to COSEC Server Application to configure COSEC ATOM Before you Start Make sure, Y The device in the package is in good condition and all the assembly parts are included. Y All the related equipments are powered-off before installation. 6 Installation 1) Installing the COSEC ATOM RD200/300: Wall Mounting Step 1: Removing the Mounting Plate Y From the bottom of the COSEC ATOM RD200/300, unscrew the Mounting screw with the help of screw driver as illustrated in Figure 8. Y Separate the Mounting plate from the ATOM by pulling it downwards. Refer, Figure 9 for the same. Mounting Plate Step 2: Connecting the Cables Y You can mount COSEC ATOM RD200/300 in two ways : Concealed Wiring or Non-concealed Wiring as explained below. A. Concealed Wiring 1. Take the Mounting Plate and trace screw holes A , B & C. Trace out the area D also drill along the marking as shown below. A D A D B B C Figure 8 7 Figure 9 C Figure 10 8 2. Affix the mounting plate with the help of the screws and screw grips through the holes A, B and C. 3. Lead the cables from the wall through the drilled area D of the Mounting Plate as illustrated in Figure 12. Connect the necessary cables with COSEC ATOM. A D B C Figure 11 9 Figure 12 10 B. Non-Concealed Wiring 1. Follow the Step 1 and Step 2 as explained for the Concealed Wiring and fix the mounting plate on the wall. (For non-concealed wiring, you do not need to drill the area D.) 3.Pull out the Cables from the Back Plate hole and lead the cables outside from the bottom opening of COSEC ATOM, as illustrated in Figure 14. Back Plate Figure 13 2. Unscrew the Back Plate screw with the help of screwdriver and remove the Back Plate. 11 Figure 14 4. Connect the necessary cables and align the COSEC ATOM body with the Mounting Plate. 12 2. Slide the reader downwards to fix it into the groove of the Mounting Plate and insert the Mounting screw back in place at the bottom of the device. 3. Tighten the screw with 2 kgf-cm torque as shown in Figure 17. Figure 15 Step 3: Inserting Mounting Screw 1. Fix the Reader body with the Mounting Plate such that the Mounting Slots of the Reader and Mounting Plate align with each other. 13 Figure 17 14 2) Installing the COSEC ATOM RD200/300: Flush Mounting Step 1: Take the Surface Mount Plate provided with the package and trace screw holes A, B, C and D on the surface where COSEC ATOM is to be installed, see Figure 18. After tracing drill along the markings as shown in Figure 19. A B A B D C Figure 18 15 D C Figure 19 Step 2: Assemble the device with the Surface Mount Plate as shown in Figure 20. 16 Step 3: To connect the cables refer below image for Concealed and Non-concealed Wiring positions. Device Surface Mount Plate Figure 20 17 Cut-out for Concealed Wiring Cut-out for Non-concealed Wiring 18 Step 4: Affix the Surface Mount Plate with the Device on the surface with the help of the screws and screw grips through the holes A, B, C and D, see Figure 21. A B Step 5: Place the Surface Mount Top Facia Plate on the installed Device, see Figure 22. D C Figure 21 19 Figure 22 Front View 20 3) Installing the COSEC ATOM RD100 Step 1: Removing the Mounting Plate Y From the top of the COSEC ATOM, unscrew the Mounting screw with the help of screw driver as illustrated in Figure 24. Y Separate the Mounting Plate from the ATOM by pulling it downwards. Refer, Figure 25 for the same. Mounting Plate Step 2: Connecting the Cables Y You can mount COSEC ATOM in two ways : Concealed Wiring or Non-concealed Wiring as explained below. A. Concealed Wiring 1. Take the Mounting Plate and trace screw holes A & B. Trace out the area C also drill along the marking as shown below. Figure 23 C A B C Figure 24 21 Figure 25 A B C Figure 26 22 2. Affix the Mounting Plate with the help of the screws and screw grips through the holes A and B. 3. Lead the cables from the wall through the drilled area C of the Mounting Plate as illustrated in Figure 24. Connect the necessary cables with COSEC ATOM, see Figure 28. Figure 28 Figure 27 23 24 B. Non- Concealed Wiring 1. Follow Step 1 and Step 2 as explained for the Concealed Wiring and fix the Mounting Plate on the wall. (For non-concealed wiring, you do not need to drill the area C.) 2. Unscrew the Back Plate screw with the help of screwdriver and remove the Back Plate. 3.Pull out the Cables from the Back Plate hole and lead the cables outside from the bottom opening of COSEC ATOM, as illustrated in Figure 30. Figure 29 25 Back Plate Figure 30 4. Connect the necessary cables and align the COSEC ATOM body with the Mounting Plate. 26 Figure 31 Figure 32 2. Slide the reader downwards to fix it with the groove of the Mounting Plate and insert the mounting screw back in place on top of the device. Step 3: Inserting Mounting Screw 1. Fix the Reader body with the Mounting Plate such that Mounting Slots of the Reader and Mounting Plate align with each other. 3. Tighten the screw with 2 kgf-cm torque as shown in Figure 33. Figure 33 27 28 Technical Specifications Specification ATOM RD300 ATOM RD200 ATOM RD100 Parameters Credential Support PIN, RFID Card, RFID Card, Card, Mobile Mobile Credential Mobile Credential Credential over BLE and over BLE and over BLE Finger Finger User Capacity Depends on Master Device **Type of Card HID I - class,MIFARE R / Desfire / Combo Cards / NFC Card Read Range MIFARE R-5 cm or more, Desfire Ev1-Atleast 4 cm MIFARE R-6 cm or more, Desfire Ev1-Atleast 4 cm Reader Interface Type RS-232, RS-485, WIFI and Wiegand RS-232, RS-485 and Wiegand Interface Support RS-232 (10ft), RS-485 (1200meter), Length Wiegand (150meter) Input Power 9-14 VDC through main door controller or external power source Buzzer Yes (>55db at 10cm) LED Keypad No Yes (in Display) Yes (Tri Colour) No Built in Bluetooth Yes BLE (4.0 and above) Yes (in ATOM RD100KM & ATOM RD100KI) Specification ATOM RD300 ATOM RD200 ATOM RD100 Parameters Tamper Detection Yes Operating Temperature -20°C to +55°C 0°C to +55°C Humidity 5% to 95% RH Non-condensing ** The type of Supported Card in COSEC ATOM is different as per their variants. Refer COSEC Server User Guide for the type of supported card in each variant. 29 30 LED and Buzzer Indications ATOM RD100/200: Connected through RS-232/ RS-485 State Single LED (tri color) Buzzer Power On Blue (ON) OFF Idle Online Idle Offline/ Network Failure Degraded Mode Processing Blue (ON: 200ms OFF OFF: 2200ms) Red (ON: 200ms OFF OFF: 2200ms) Orange (ON: 200ms OFF OFF: 2200ms) Green (ON: 200ms) OFF Red (ON: 200ms) Wait Green (ON: 200ms) ON: 200ms Red (ON: 200ms OFF: 1000ms OFF: 800ms) Alarm Minor Alarm Major Alarm Critical Red (ON: 200ms OFF: 1000ms) Red (ON: 400ms OFF: 800ms) Red (ON till Reset) ON: 200ms OFF: 1000ms ON: 400ms OFF: 800ms ON till Reset 31 State Alarm Clear Single LED (tri color) OFF Buzzer OFF Access Allowed Green (ON: 1200ms) ON: 1200ms Access Denied Red (ON: 200ms OFF: 200ms) 3 Cycles ON: 200ms OFF: 200ms 3 Cycles System Default Red (ON: 400ms OFF: 200ms) Lost Connectivity Red (ON: 200ms with the ARC OFF: 200ms) Controller ON till Reset OFF ATOM RD300: Connected through RS-232/ RS-485 State Buzzer Power On ON (1s) Idle Online OFF Idle Offline/ Network Failure OFF Degraded Mode OFF 32 State Processing Wait Alarm Minor Alarm Major Alarm Critical Alarm Clear Access Allowed Access Denied System Default Lost Connectivity with the ARC Controller Buzzer No Change ON: 200ms OFF: 1000ms ON: 200ms OFF: 1000ms ON: 400ms OFF: 800ms ON till Reset OFF ON: 1200ms ON: 200ms OFF: 200ms 3 Cycles ON till Reset OFF 33 ATOM RD100/200/300: Connected through Wiegand Interface State Single LED (tri color) Buzzer Idle Blue (ON: 200ms No Change OFF: 2200ms Card Detection/ Green (ON: 100ms) ON: 100ms PIN Transmission/ BLE Punch Key Press No Change ON: 100ms Failed System Default Red (ON: 200ms OFF: 200ms) 3 Cycles Red (ON: 400ms OFF: 200ms) ON: 200ms OFF: 200ms 3 Cycles ON till Reset 34 Connecting the Reader 1. RS-232 connectivity for COSEC Doors, COSEC VEGA, COSEC PATH and COSEC ARGO. 2. RS-485 connectivity for COSEC ARC. 3. Wiegand connectivity for 3rd party Access Control Panel. RS-485 RS-485 A Blue RS-485 B Brown GND Black +12V_RDR White GND Black TO COSEC ARC Controllers Figure 35 COSEC ATOM Figure 34 GND RS232 TX RS232 RX TEMPER W DATA1 W DATA0 BEEPER RED LED GREEN LED GND +12V_RDR Black Grey Pink Light Blue White Green Yellow Purple Orange Black Red RS-232 D1 D0 Wiegand Interface TO COSEC DOORs Figure 36 1 23 4 56 7 ESC 8 0 9 ENT 35 Pin Diagram TO 3RD PARTY ACCESS CONTROL DEVICES Figure 37 36 FCC Compliance This device complies with part15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits of Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Warning This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. FCC Certification in-progress for ATOM 200/300 37 Caution: Disposal of Product after End-Of-Life AthWneyEpCEahEratynDgrireeesscpotoirvnmesi2obd0lei0ffi2oc/ar9tc6ioo/mnEsCpnlioatnecxepcroeuslsdlyvaopidptrhoeveudsebry's auTthheoprriotydutoctorpefeerreadteisthceoveeqreudipbmy tehnetw. aste Electrical and FCEClecRtFroRnaicdEiaqtuioipnmEexnpt o(WsuErEeE)Stdairteecmtiveenatn:d must be disposed 1.oTfhinisaTrreasnpsomnsiitbtleermmaunnstern. ot be co-located or operating inAct othnejuenndctoiof nprwodituhctalnifey ocythcleer; baanttteerniensa, soorldtrearendsbmoiatrtdesr,. 2li.mmtThrheiottisauslgsecheqotrumefiocppyromctnhleeenrfnsotts.rcaaonnmduppnllaicesotsincwtcriotohmlleRpdFonreeanndvtisiaromtinoumnsteebxneptd.oisspuorseed 3m.IlTofihncyaiiosmtueeuaqerm-uewiupdansmisatetbealrnenetctcosyehcd2loies0urpsclo,mdsyebob-euoefimtfnwtasheyteaerlpnelertoutdhrdneaucntrhtdasedoopirparoutedonruarac&bttelseydottoowuritbhody. Matrix Return Material Authorization (RMA) department. MATRIX COMSEC PVT. LTD. Head Office 394-GIDC, Makarpura, Vadodara, Gujarat, 390010, India Ph: (+91)1800-258-7747 Email: Support@MatrixComSec.com www.matrixaccesscontrol.com V 1.3, March 2021Corel PDF Engine Version 19.1.0.419