Measurement and Test Report
For Eggtronic Engineering Srl
Via Giorgio Campagna 8 41126 Modena (MO) Italy
FCC ID: 2ANP7PPBK2
Model: PRBK2
Report No.: WTX19X09062900W-2
Tested Date: 2019-09-09
Issued Date: 2019-09-09 to 2019-09-16
Tested By: 2019-09-16
Reviewed By: Silin Chen / EMC Manager
Approved & Authorized By: Jandy So / PSQ Manager
Prepared By: Shenzhen SEM Test Technology Co., Ltd.
1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao'an District, Shenzhen, P.R.C. (518101)
Tel: +86-755-33663308 Fax: +86-755-33663309 Website: www.semtest.com.cn
Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen SEM Test Technology Co., Ltd.
1. General Information
1.1 Product Description for Equipment Under Test (EUT)
Client Information
Applicant: Eggtronic Engineering Srl
Address of applicant: Via Giorgio Campagna 8 41126 Modena (MO) Italy
Manufacturer Information
Manufacturer: Shenzhen Pilot Technology Co.,Ltd
Address of manufacturer: A1 Building, No.7 Shankeng Road, Shankeng Industrial Park, Shanxia Community, Pinghu Street, Longgang District, Shenzhen, China.
General Description of EUT
Product Name: | Wireless Power Bank |
Trade Name: | EGGTRONIC |
Model No.: | PRBK2 |
Adding Model(s): | PRBL2,PRGR2,PPBK2,PPBL2,PPGR2 |
Battery Capacity: | 1500mAh |
Note: The test data is gathered from a production sample, provided by the manufacturer. The appearance of others models listed in the report is different from main-test model PRBK2, but the circuit and the electronic construction do not change, declared by the manufacturer.
Technical Characteristics of EUT
Frequency Range: | 110~205kHz |
Antenna Type: | Coil Antenna |
Rated Voltage: | DC5V (Wireless output) |
Rated Current: | ≤1A (Wireless output) |
Rated Power: | ≤ 5W (Wireless output) |
2. RF Exposure Test Report
2.1 Standard Applicable
According to § 1.1310 system operating under the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure.
Table 1 - Limits for Maximum Permissible Exposure (MPE)
Frequency range (MHz) | (A) Limits for Occupational/Controlled Exposure | Averaging time (minutes) | ||
---|---|---|---|---|
Electric field strength (V/m) | Magnetic field strength (A/m) | Power density (mW/cm²) | ||
0.3-3.0 | 1842/f | 4.89/f | *100 | 6 |
3.0-30 | 61.4 | 0.163 | *900/f² | 6 |
30-300 | 61.4 | 0.163 | 1.0 | 6 |
300-1,500 | f/300 | f/300 | f/300 | 6 |
1,500-100,000 | 5 | 5 | 5 | 6 |
0.3-1.34 | 614 | 1.63 | *100 | 30 |
1.34-30 | 824/f | 2.19/f | *180/f² | 30 |
30-300 | 27.5 | 0.073 | 0.2 | 30 |
300-1,500 | f/1500 | f/1500 | f/1500 | 30 |
1,500-100,000 | 1.0 | 1.0 | 1.0 | 30 |
f = frequency in MHz * = Plane-wave equivalent power density
2.2 Test Conditions
Test Mode | Description | Remark | Power Supply Mode |
TM1 | Wireless charging | Transmit | DC 5V (with a adapter input AC 120V/60Hz) |
Measurement Distance: 15 cm
2.3 Test Procedure
Test Setup Description: The measurement probe was placed at test distances of 15 cm for points A, B, C, D, F, and 20 cm for point E, which is between the edge of the charger and the geometric center of the probe. The highest emission level was recorded at these measurement points (A, B, C, D, E, F). The EUT was measured according to the distance requirements of KDB 680106 D01 V03.
2.4 Test Result
The EUT complies with item 5.2 of KDB 680106 D01V03.
- Power transfer frequency is less than 1 MHz: Yes, the device operates in the frequency range from 110kHz to 205kHz.
- Output power from each primary coil is less than 15 watts: Yes, the maximum output power of the primary coil is less than 15W.
- The transfer system includes only single primary and secondary coils: Yes, the client device includes only single primary coils.
- Client device is inserted in or placed directly in contact with the transmitter: Yes, Client device is placed directly in contact with the transmitter.
- Mobile exposure conditions only: Yes, It is mobile exposure conditions only.
- Aggregate field strengths: The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes, the EUT field strength levels are less than 50% of the MPE limit, refer to test TM1, TM2 list, and the coils can't transmitted simultaneous.
Test Mode: TM1 - Electric Field Emissions
Test Position | Measure Value (V/m) | Limit(V/m) | 50% Limit (V/m) |
---|---|---|---|
Top | 6.41 | 614 | 307 |
Bottom | 6.46 | 614 | 307 |
Side 1 | 7.53 | 614 | 307 |
Side 2 | 8.70 | 614 | 307 |
Side 3 | 6.00 | 614 | 307 |
Side 4 | 5.65 | 614 | 307 |
Test Mode: TM1 - Magnetic Field Emissions
Test Position | Measure Value (A/m) | Limit(A/m) | 50% Limit (A/m) |
---|---|---|---|
Top | 0.80 | 1.63 | 0.815 |
Bottom | 0.78 | 1.63 | 0.815 |
Side 1 | 0.71 | 1.63 | 0.815 |
Side 2 | 0.62 | 1.63 | 0.815 |
Side 3 | 0.81 | 1.63 | 0.815 |
Side 4 | 0.80 | 1.63 | 0.815 |
2.4 Test Photos
Description: The image shows the test setup for measuring RF emissions from the Wireless Power Bank. A white smartphone is placed on a wooden surface, connected to a charging coil. A measurement probe, mounted on a tripod, is positioned near the device to capture electric and magnetic field strengths.