Eggtronic PRBK2 Wireless Power Bank RF Exposure Test Report

Measurement and Test Report

For Eggtronic Engineering Srl

Via Giorgio Campagna 8 41126 Modena (MO) Italy

FCC ID: 2ANP7PPBK2

Model: PRBK2

Report No.: WTX19X09062900W-2

Tested Date: 2019-09-09

Issued Date: 2019-09-09 to 2019-09-16

Tested By: 2019-09-16

Reviewed By: Silin Chen / EMC Manager

Approved & Authorized By: Jandy So / PSQ Manager

Prepared By: Shenzhen SEM Test Technology Co., Ltd.

1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao'an District, Shenzhen, P.R.C. (518101)

Tel: +86-755-33663308 Fax: +86-755-33663309 Website: www.semtest.com.cn

Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen SEM Test Technology Co., Ltd.

1. General Information

1.1 Product Description for Equipment Under Test (EUT)

Client Information

Applicant: Eggtronic Engineering Srl

Address of applicant: Via Giorgio Campagna 8 41126 Modena (MO) Italy

Manufacturer Information

Manufacturer: Shenzhen Pilot Technology Co.,Ltd

Address of manufacturer: A1 Building, No.7 Shankeng Road, Shankeng Industrial Park, Shanxia Community, Pinghu Street, Longgang District, Shenzhen, China.

General Description of EUT

Product Name:Wireless Power Bank
Trade Name:EGGTRONIC
Model No.:PRBK2
Adding Model(s):PRBL2,PRGR2,PPBK2,PPBL2,PPGR2
Battery Capacity:1500mAh

Note: The test data is gathered from a production sample, provided by the manufacturer. The appearance of others models listed in the report is different from main-test model PRBK2, but the circuit and the electronic construction do not change, declared by the manufacturer.

Technical Characteristics of EUT

Frequency Range:110~205kHz
Antenna Type:Coil Antenna
Rated Voltage:DC5V (Wireless output)
Rated Current:≤1A (Wireless output)
Rated Power:≤ 5W (Wireless output)

2. RF Exposure Test Report

2.1 Standard Applicable

According to § 1.1310 system operating under the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure.

Table 1 - Limits for Maximum Permissible Exposure (MPE)

Frequency range (MHz)(A) Limits for Occupational/Controlled ExposureAveraging time (minutes)
Electric field strength (V/m)Magnetic field strength (A/m)Power density (mW/cm²)
0.3-3.01842/f4.89/f*1006
3.0-3061.40.163*900/f²6
30-30061.40.1631.06
300-1,500f/300f/300f/3006
1,500-100,0005556
0.3-1.346141.63*10030
1.34-30824/f2.19/f*180/f²30
30-30027.50.0730.230
300-1,500f/1500f/1500f/150030
1,500-100,0001.01.01.030

f = frequency in MHz * = Plane-wave equivalent power density

2.2 Test Conditions

Test ModeDescriptionRemarkPower Supply Mode
TM1Wireless chargingTransmitDC 5V (with a adapter input AC 120V/60Hz)

Measurement Distance: 15 cm

2.3 Test Procedure

Test Setup Description: The measurement probe was placed at test distances of 15 cm for points A, B, C, D, F, and 20 cm for point E, which is between the edge of the charger and the geometric center of the probe. The highest emission level was recorded at these measurement points (A, B, C, D, E, F). The EUT was measured according to the distance requirements of KDB 680106 D01 V03.

2.4 Test Result

The EUT complies with item 5.2 of KDB 680106 D01V03.

  1. Power transfer frequency is less than 1 MHz: Yes, the device operates in the frequency range from 110kHz to 205kHz.
  2. Output power from each primary coil is less than 15 watts: Yes, the maximum output power of the primary coil is less than 15W.
  3. The transfer system includes only single primary and secondary coils: Yes, the client device includes only single primary coils.
  4. Client device is inserted in or placed directly in contact with the transmitter: Yes, Client device is placed directly in contact with the transmitter.
  5. Mobile exposure conditions only: Yes, It is mobile exposure conditions only.
  6. Aggregate field strengths: The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes, the EUT field strength levels are less than 50% of the MPE limit, refer to test TM1, TM2 list, and the coils can't transmitted simultaneous.

Test Mode: TM1 - Electric Field Emissions

Test PositionMeasure Value (V/m)Limit(V/m)50% Limit (V/m)
Top6.41614307
Bottom6.46614307
Side 17.53614307
Side 28.70614307
Side 36.00614307
Side 45.65614307

Test Mode: TM1 - Magnetic Field Emissions

Test PositionMeasure Value (A/m)Limit(A/m)50% Limit (A/m)
Top0.801.630.815
Bottom0.781.630.815
Side 10.711.630.815
Side 20.621.630.815
Side 30.811.630.815
Side 40.801.630.815

2.4 Test Photos

Description: The image shows the test setup for measuring RF emissions from the Wireless Power Bank. A white smartphone is placed on a wooden surface, connected to a charging coil. A measurement probe, mounted on a tripod, is positioned near the device to capture electric and magnetic field strengths.

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=4473626 Microsoft Word 2010 Microsoft Word 2010

Related Documents

Preview Eggtronic 4-in-1 Wireless Charging Power Stand PSBK10 User Manual
User manual for the Eggtronic 4-in-1 Wireless Charging Power Stand (Model: PSBK10). Learn how to use it as a wireless charging stand, power bank, or charging pad. Includes specifications, safety information, and troubleshooting.
Preview Eggtronic Quality Policy: Driving Innovation in Power Electronics
Discover Eggtronic's commitment to quality, innovation, and excellence in power electronics. This policy outlines their mission, vision, and core values for developing advanced technologies.