User Manual for Minoston models including: Smart Dimmer Toggle Switch
Manufacturer Manual
File Info : application/pdf, 4 Pages, 574.28KB
DocumentDocumentSmart Dimmer Toggle Switch Manual Federal Communications Commission (FCC) Statement FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may caus harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. IC Caution: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. DECLARATION DE CONFORMITE D'INDUSTRIE CANADA Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210. Son utilisation est soumise aux deux conditions suivantes : (1) il ne doit pas provoquer d'interférences gênantes et (2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement. Smart Dimmer Toggle Switch WARRANTY Minoston Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period. SPECIFICATIONS WARNING Model:MS13ZS RISK OF FIRE Power: 120 VAC, 60 Hz. RISK OF ELECTRICAL SHOCK Signal (Frequency): 908.42 MHZ. RISK OF BURNS Maximum Loads: 500W, 2-gang 400W or 3-gang CONTROLLING APPLIANCES: 300W incandescent, 100W CFL/LED EXERCISE EXTREME CAUTION WHEN USING Z-Wave DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave DEVICE MAY BE IN A DIFFERENT Range: Up to 100 feet line of sight between the Wireless ControRlOlOeMr THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION and the closest Z-Wave receiver module. MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave DEVICES Operating Temperature Range: 32-104° F (0-40° C) MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING. For Ourdoor use DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL Specifications subject to change without notice OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE due to continuing product improvement REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE THE FOLLOWING: DO NOT USE Z-Wave DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL. Introduction: This product can be operated in any Z-Wave network with other Z-Wave PlusTM certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination. MS13ZS is a security enabled Z-Wave PlusTM device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product. The Device Type of the MS13ZS is Dimmer power switch. The Role Type of the MS13ZS is Always On Slave Role Type Key Features: ---Remote ON/OFF control via the Z-Wave controller ---Manual ON/OFF control with the front panel push button ---Support Association Group and Auto Report switch status ---Support firmware upgrades via Over-the-air (need Gateways support) ---Support Scenes C F Product Overview: A. Up Push button A B. Down Push button C. Load (Black) D. Lin (Black) - Line in B D E E. Nin (White) - Nutral in F. 3-way (RED) MS13ZS Installation Wiring Diagram Key function description Function 1: Function 2: Press the up or down button to turn the output ON or OFF Hold Dimmer Up or Dimmer Down Function 3: Function 4: Press the up or down button three times quickly to ADD and REMOVE Press the up or down button six times quickly to change Status LED Configuration Function 5: When switch is off and quickly press UPPER paddle 2 times, switch turns on to 100% brightness Function 6: Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory (Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable.) Function 7: Function 8: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene. Tap B(1x/2x/3x/4x/5x/Hold/Release) Activate the scene. Led Indicate Function 1:Flash two times When configuration parameter succeed LED flash two times 2:quickly flash When inclusion or exclusion or reset, LED will quickly flash till operate complete Z-Wave Remote Control ADD or Remove the MS13ZS from the existing Z-Wave home control network with your primary controller. ---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure. ---When prompted by your primary controller, click the Up or Down button three times in one second. Include MS13ZS to/from a Z-Wave Gateway with supporting Security.The MS13ZS can support the Primary Controller that implemented the security S2. Notice: Including a node ID allocated by Z-WaveTM Controller means "Add" or "Inclusion". Excluding a node ID allocated by Z-WaveTM Controller means "Remove" or "Exclusion". Z-Wave protocol Command Class Node Info COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_SWITCH_MULTILEVEL, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_TRANSPORT_SERVICE, COMMAND_CLASS_VERSION, COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_DEVICE_RESET_LOCALLY, COMMAND_CLASS_POWERLEVEL, COMMAND_CLASS_CONFIGURATION, COMMAND_CLASS_CENTRAL_SCENE, COMMAND_CLASS_SECURITY_2, COMMAND_CLASS_SUPERVISION COMMAND_CLASS_FIRMWARE_UPDATE_MD The Below listed Command Class are all supported the Security S2 COMMAND_CLASS_SWITCH_MULTILEVEL, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_VERSION, COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_DEVICE_RESET_LOCALLY, COMMAND_CLASS_CENTRAL_SCENE, COMMAND_CLASS_CONFIGURATION, COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_FIRMWARE_UPDATE_MD Z-Wave Configuration Parameters You may use the below configuration parameters to change settings of the corresponding functionality. 1: Locally Button function Paramter No: 1(0x01) Size:1 Byte Value: 00(default) Up Button ON,Down Button OFF Value: 01 Value: 02 Up Button OFF,Down Button ON Up Button: On/Off Down Button: On/Off 2Status LED Configuration Paramter No: 2(0x02) Size:1 Byte Value: 00(default) Value: 01 Output and the LED are in the different state. Output and the LED are in the same state. Value: 02 Value: 03 Always OFF Always ON 3Enable Auto Turn-OFF Timer Paramter No: 3(0x03)Size=1Value=0 Auto Turn-OFF Timer Disabled (default); Value=1 Auto Turn-OFF Timer Enabled 4Count Down Configuration(Turn off the output by time Paramter No: 4(0x04) Size:4 Byte Value: xx xx Turn off Output Value Scope :1----65535Minutes (default:00 3C no timer) 5Enable Auto Turn-ON Timer Paramter No: 5(0x05)Size=1Value=0 Auto Turn-ON Timer Disabled (default); Value=1 Auto Turn-ON Timer Enabled 6Count Down Configuration(Turn ON the output by time Paramter No: 6(0x06) Size:4 Byte Value: xx xx Turn ON Output Value Scope :1----65535Minutes (default:00 3C no timer) 7Association Setting Parameter Paramter No: 7(0x07) Size:1 Byte Value: 00 None Value: 01 Local Value: 02 Value: 04 3-way Z-Wave hub Value: 03 Value: 05 3-way&Local Z-Wave hub&Local Value: 06 Value: 08 Z-Wave hub&3-way Timer Value: 07 Value: 09 Z-Wave hub&Local&3-way Timer&Local Value: 10 Value: 12 Timer&3-way Timer&Z-Wave hub Value: 11 Timer&3-way&Local Value: 13 Timer&Z-Wave hub&Local Value: 14 Timer&Z-Wave hub&3-way Value: 15 All(Defaul) 8Restores state after power failure Paramter No: 8(0x08) Size:1 Byte Value: 00 Output OFF. Value: 01 Output ON. Value: 02 (default) The state before a power outage. 9Dimmer Speed Parameter Local Button Paramter No: 9(0x09) Size:1 Byte Value: 01(default) Value: 02 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s from 0x63 to 0x00 or from 0x00 to 0x63 need 2s ............... Value: 99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s 10Multilevel minimum value can be setThe minimum luminance value of the dimmingLocal Button Paramter No: 10(0x0A) Size:1 Byte Value: 00 Value: 01 (default) ............... Value: 99 11Multilevel maxmum value can be setThe maxmum luminance value of the dimmingLocal Button Paramter No: 11(0x0B) Size:1 Byte Value: 00 (default) Value: 01 ............... ` 12when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness Local Button Paramter No: 12(0x0C) Size:1 Byte Value: 00 Value: 01 Turn ON to 99 (default) turn on to the value relate with parameter 11 Notice:when parameter 12 value is 0,the parameter 11 can not be set , and the value always is 0 14: Double Tap Behavior Paramter No: 14(0x0E)Size=1Default =0 Value=0 enable double tap to full brightness (or max/custom brightness set in Par11/Par12), single tap to last brightness level Value=1 Value=2 disable double tap to full brightness, single tap to last brightness level disable double tap to full brightness, single tap always to full brightness 15: Enable or Disable local control (or max/custom brightness set in Par11/Par12) Paramter No: 15(0x0F)Size=1Default =1 Value=0 disable(when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave and it will change LED indicator status depending if light is turned on or turned off) Value=1 enable (normal operation like now) Support for Association Groups MS13ZS supports 2 association groups. Group 1 support 1 node ID,Group 2 Support maximum of 5 node ID's Association group_1:Z-Wave Plus Lifeline Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MS13ZS Status change report, 1. MS13ZS will trigger AUTO report function if the Switch status had been changed. Association group_2:basic set command When the output of the MS13ZS is changed, The MS13ZS will automatically send out a related basic set command. Restoring Factory Defaults MS13ZS is removed from the network and will be restored to the factory setting All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network. Remark : All the setting and data will be permanently deleted. Please use this procedure only when the network primary controller is missing or otherwise inoperable.Microsoft: Print To PDF