Solax X3-HYB-G4 PRO: Three-Phase Hybrid Inverter for Home Use
The Solax X3-HYB-G4 PRO is a three-phase hybrid inverter designed for residential applications, offering advanced features for energy management and reliability.
Key Features
Intelligent Management
- V2X-Ready for integration into smart home applications
- Individual operating modes, also considering dynamic electricity tariffs
- Compatible with Wireless Bridge
- VPP-ready with different providers and protocols (OpenADR, IEEE2030.5, FCAS, API)*
High Performance
- 20A DC input per MPPT with 3 trackers
- 200% PV oversizing and up to 110% AC output
- Ultra-wide MPPT range from 110-950V
High Reliability
- Up to 200% EPS output for 10s
- UPS-level switching time <10ms
- Optional fast shutdown function for increased safety
- Type II SPD on AC & DC side
- Optional AFCI protection*
Flexible, Variable, Scalable
- Two battery connections and 2-in-1 function for expansion
- Additional connections for simplified wiring and installation
- Functional and elegant cable cover
- Micro-Grid and Generator modes for versatile operation
* Functionality to be expanded in the future.
Performance Curve
The efficiency curve for the 15kW model shows that maximum efficiency (around 98%) is achieved at loads between 75% and 100%. Efficiency increases significantly from 5% load (around 86%) up to higher load levels.
Schematic Diagram Description
The schematic diagram illustrates the internal connections of the inverter. Key components include PV inputs (PV1, PV2, PV3 with positive and negative terminals), DC switch, MPPT trackers (1, 2, 3), DC Surge Protection Device (SPD), battery connections (BAT1, BAT2), DC Bus, the main Inverter circuit, AC Surge Protection Device (SPD), and connections to the Grid (L1, L2, L3, N) and EPS (Emergency Power Supply - L1, L2, L3, N). Various filters (PV EMI, EMI, LCL) and circuits are also depicted.
Technical Specifications
X3-HYB-4.0-P | X3-HYB-5.0-P | X3-HYB-6.0-P | X3-HYB-8.0-P | X3-HYB-10.0-P | X3-HYB-12.0-P | X3-HYB-15.0-P | ||
---|---|---|---|---|---|---|---|---|
PV INPUT | ||||||||
Max. recommended PV system power | 8 kWp | 10 kWp | 12 kWp | 16 kWp | 20 kWp | 24 kWp | 30 kWp | |
Max. PV input voltage | 1000 V | |||||||
PV nominal input voltage | 650 V | |||||||
Operating voltage range | 110~950 V | |||||||
MPPT voltage range | 110~950 V | |||||||
Startup voltage (StandBy - Display on) | 120 V | |||||||
Number of MPPT trackers / Strings per MPPT tracker | 2 (1/1) | 3 (1/1/1) | ||||||
Max. input current per MPPT (MPPT1/2/3) | 20 A / 20 A | 20 A / 20 A / 20 A | ||||||
Max. input short-circuit current per MPPT (MPPT1/2/3) | 25 A / 25 A | 25 A / 25 A / 25 A | ||||||
AC INPUT AND OUTPUT (PARALLEL GRID OPERATION) | ||||||||
Nominal output power | 4000 W | 5000 W (AS 4777 4999 W) | 6000 W | 8000 W | 10000 W (AS 4777 9999 W) | 12000 W | 15000 W (AS 4777 14999 W) | |
Nominal output current | 5.8 A | 7.2 A | 8.7 A | 11.6 A | 14.5 A | 17.5 A | 21.8 A | |
Max. apparent output power | 4400 VA | 5500 VA (AS 4777 4999 VA) | 6600 VA | 8800 VA | 11000 VA (AS 4777 9999 VA) | 13200 VA | 16500 VA (AS 4777 14999 VA) | |
Max. continuous output current | 6.7 A | 6.7A | 8.4 A | 10.0 A | 13.4 A | 20.0 A | 25.0 A | |
AC nominal voltage | 3/N/PE, 220/380 V | 3/N/PE, 230/400 V | ||||||
Max. AC input apparent power | 8.4 kVA | 10.5 kVA | 12.6 kVA | 16.8 kVA | 21.0 kVA | 24.3 A | 30.4 A | |
Max. AC input current | 12.2 A | 15.2 A | 18.2 A | |||||
AC nominal frequency | 50 Hz / 60 Hz | |||||||
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz | |||||||
Adjustable power factor range | ~ 1 (0.8 lagging to 0.8 leading) | |||||||
THDi (nominal power) | < 3% | |||||||
BATTERY | ||||||||
Battery type | LFP | |||||||
Battery voltage range | 130 ~ 800 V | |||||||
Max. charge/discharge current | 50 A (25 A x 2) | |||||||
EPS (OFF-GRID) OUTPUT (WITH BATTERY) | ||||||||
EPS nominal output voltage, frequency | 400 V / 230 V, 50 Hz / 60 Hz | |||||||
EPS nominal output power | 4 kVA | 5 kVA | 6 kVA | 8 kVA | 10 kVA | 12 kVA | 15 kVA | |
EPS peak output power | 2x nominal power, 10s | |||||||
Switching time | < 10 ms | |||||||
EFFICIENCY | ||||||||
Max. efficiency | 98.0% | |||||||
European efficiency | 97.7% | |||||||
FURTHER PARAMETERS | ||||||||
Protection class | IP66 | |||||||
Operating temperature range | -35 ~ 60°C | |||||||
Max. operating altitude | 3000 m | |||||||
Relative humidity | 0~100% RH (Condensing) | |||||||
Surge category | Mains: III, Battery: II, PV: II | |||||||
GENERAL | ||||||||
Dimensions (W x H x D) | 560 x 503 x 210 mm | |||||||
Net weight | 38 kg | |||||||
Cooling concept | Natural Cooling | Intelligent Cooling | ||||||
Communication interfaces | COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, Meter / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heatpump) | |||||||
Power consumption (Night) | < 40 W in standby, < 5 W in idle | |||||||
Topology | Transformerless | |||||||
Certificates and approvals | IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 | |||||||
AC auxiliary power supply (APS) | Integrated, supplied via mains voltage | |||||||
PROTECTION | ||||||||
Measures | Over/under voltage protection, DC insulation protection, DC reverse polarity protection, grid monitoring, DC feed-in monitoring, reverse current monitoring, fault current detection, over-temperature protection, AC overcurrent protection, AC short-circuit protection, Frequency shift | |||||||
Surge protection (DC/AC) | DC: Type II, AC: Type II | |||||||
Arc fault interrupter (AFCI) | Optional |
Footnotes:
- ① The maximum input voltage is the upper limit of the DC voltage. A higher input DC voltage would likely damage the inverter.
- ② An input voltage exceeding the MPPT voltage range may trigger inverter protection.
- ③ The AC frequency range may vary by country.
- ④ When both battery connections are used with a separate battery, the current is 25 A per connection. If one connection is used with a single battery, it is 30 A. If both connections are connected to a single battery using a 2-in-1 splitter cable (sold separately), the current is 50 A.
- ⑤ Power derating above +45°C.
Contact Information
Website: www.solaxpower.com
Email: info@solaxpower.com
Phone: +86 571-56260008
*V2.4.1 Information is subject to change without prior notice.