User Manual for files thru the air models including: WA-PRO-THP Temperature and Humidity Limit Alert Sensor, WA-PRO-THP, Temperature and Humidity Limit Alert Sensor
and Guides for the FilesThruTheAir Product Range
FilesThruTheAir Resources and Software
File Info : application/pdf, 3 Pages, 635.07KB
DocumentDocumentWireless Alert PRO THP Temperature & Humidity Limit Alert Sensor -30 °C to +80 °C Temperature Range 0 %RH to 100 %RH Humidity Range · Temperature and humidity limit alert sensor from the FilesThruTheAir Wireless Alert PRO range · Configurable high and low alert limits · Monitor temperature and humidity in occupied spaces, storage areas and many other applications · Wi-Fi-connected · Get notified and view the latest status of your device using the FilesThruTheAir app · Receive email alerts and scheduled status reports · Flashing alert indicator Download the FilesThruTheAir app for free FilesThruTheAir's WA-PRO-THP provides alert notifications when user-selected high and low temperature or humidity limits are breached. Power this device via its USB-C socket and set it up using the free FilesThruTheAir app. Configuration options include connection to a Wi-Fi network, temperature and humidity alert limit selection, and notification options. Notifications can be pushed direct to your smartphone or sent by email. Emailed scheduled summary reports detailing minimum, maximum and average readings, power status, number of alerts, and total time spent in alert are also available. A quick look at the FilesThruTheAir app dashboard will show the alert status and last reported reading of any devices connected to your account. www.filesthrutheair.com/wireless-alert-pro FilesThruTheAirTM is a trademark of Corintech Ltd. Ashford Mill, Station Road, Fordingbridge, Hampshire, SP6 1DZ, UK Issue 2 08/08/2022 Page 1 of 3 Wireless Alert PRO THP Specification WA-PRO-THP Temperature Measurement Range Temperature Measurement Resolution Temperature Measurement Accuracy 1 Device Operating Temperature Humidity Measurement Range Humidity Measurement Resolution Humidity Measurement Accuracy (@25°C) 1 Alert Levels Response Time Power Supply Wi-Fi Product Dimensions Probe Dimensions (Without Bracket) Cable Length Minimum Typical Maximum -30 to +80 (-22 to +176) 0.1 (0.1) ±0.3 (+5 to +60) (±0.6 (+41 to +140)) ±0.8 (-20 to +60) (±1.6 (-4 to +140)) -20 to +60°C (-4 to +140°F) 0 to 100 1 ±2 (20 to 80) ±5 (0 to 100) User-configurable, within measurement range stated above 1 minute USB-C 5V 1.0A WPA2/WPA3 Personal, WPA2 Enterprise (MSCHAP/PEAP, TTLS) - 802.11bgn (2.4GHz) L 61 (2.4) x W 29 (1.14) x D 13 (0.5) 37 x 12 x 8 (1.5 x 0.5 x 0.3) 2000 (79) Unit °C (°F) °C (°F) °C (range) (°F (range)) °C (°F) %RH %RH %RH mm (inches) mm (inches) mm (inches) What's in the Box Accessories Available Part Number WA-PRO-THP WA-PRO-BRACKET WA-PRO-QSG USB-C-2M-WHT Description Temperature/Humdity Alert Sensor Mounting Bracket and Fixing Screws Quickstart guide USB-C Cable 2m Wireless Alert PRO Range Part Number EL-SP-TH PSU-5VDC-USB-INTL-WHT WA-PRO-UPS 2 WA-PRO-THP CAL Description Replacement TH Probe Power Supply UPS / Backup Battery Calibration Certificate Part Number WA-PRO-T WA-PRO-T+ WA-PRO-THP WA-PRO-THP+ WA-PRO-TP WA-PRO-TP+ WA-PRO-TC WA-PRO-VAC WA-PRO-ULT 2 WA-PRO-ULT+ 2 WA-PRO-420 2 Description Wi-Fi-Connected Ambient Temperature Limit Alert (-20 °C to +60 °C) Wi-Fi-Connected High-Accuracy Ambient Temperature Limit Alert (-20 °C to +60 °C) Wi-Fi-Connected Temperature and Humidity Limit Alert (-30 °C to +80 °C, 0 %RH to 100 %RH) Wi-Fi-Connected High-Accuracy Temperature and Humidity Limit Alert (-30 °C to +80 °C, 0 %RH to 100 %RH) Wi-Fi-Connected Temperature Limit Alert (-40 °C to +125 °C) Wi-Fi-Connected High-Accuracy Temperature Limit Alert (-40 °C to +125 °C) Wi-Fi-Connected Thermocouple Temperature Limit Alert (0 °C to 200 °C with supplied K Type Thermocouple) Wi-Fi-Connected Vaccine Temperature Limit Alert (-40 °C to +125 °C) Wi-Fi-Connected Ultra-Low Temperature Limit Alert (-100 °C to +100 °C with supplied T Type Thermocouple) Wi-Fi-Connected High-Accuracy Ultra-Low Temperature Limit Alert (-100 °C to +100 °C with supplied T Type Thermocouple) Wi-Fi-Connected 4-20mA Limit Alert (4 mA to 20 mA) 1) For more detailed specifications, refer to page 3 of this data sheet. 2) Coming soon. Specifications liable to change without prior warning. Other Wi-Fi connected products from FilesThruTheAirTM FilesThruTheAir offer a variety of sensors and data loggers. Visit www.filesthrutheair.com to find out if we have something to fit your application. www.filesthrutheair.com/wireless-alert-pro FilesThruTheAirTM is a trademark of Corintech Ltd. Ashford Mill, Station Road, Fordingbridge, Hampshire, SP6 1DZ, UK Issue 2 08/08/2022 Page 2 of 3 Wireless Alert PRO THP SENSOR ACCURACY & INFORMATION The sensor in this device is protected in storage and transit by a peelable protective film, this will need to be removed before the device is used. Typical and mTa(x°iCmal tolerance for temperature sensor in °C. T (°C) T (°C ±T2(.0°C maximum error ± 1.5 typical accuracy ± 1.0 ± 0.5 ± 0.0 -40 -20 0 20 40 60 80 Temperature (°C) Typical and maximal tolerance at 25°C for relative humidity. RH (%RH) ± 10 ± 8 maximum error typical accuracy ± 6 ± 4 ± 2 ± 0 0 10 20 30 40 50 60 70 80 90 100 Relative Humidity (%RH) Relative Humidity (%RH) Relative Humidity (%) Typical accuracy of relative humidity measurements given in %RH for temperatures 0 to 80°C. 100 ±3.5 ±3 90 ±2.5 80 70 ±3 ±2.5 60 50 ±2.5 ±2 40 30 20 10 ±3 ±2.5 0 ±3.5 ±3 ±3.5 ±4 ±3 ±3.5 ±3 ±3.5 ±3 0 10 20 30 40 50 60 70 80 Temperature (°C) Operating conditions 100 80 60 Normal Max. 40 Range Range 20 0 -40 -20 0 20 40 60 80 100 120 Temperature (°C) Long term exposure to humidity levels outside of the `normal' range may temporarily offset RH measurements (±3%RH after 60 hours). Once returned to less extreme conditions the device will slowly return towards calibration state. When tracking changes in ambient conditions, the response time of the humidity sensor in your Wireless Alert PRO is approximately 20 minutes to reach 90% of the reading. However, if you are measuring step changes in humidity (for example if calibrating the product) it is advised that you leave the unit for up to four hours to ensure that it has enough time to settle at the new level. It is worth remembering that the value of relative humidity is of course sensitive to temperature variation. As an example, at a relative humidity of ~90%RH at ambient temperature, a variation in temperature of 1°C will result in a change of up to -5%RH. Therefore when comparing multiple devices or calibrating them, any temperature variations must be considered. www.filesthrutheair.com/wireless-alert-pro FilesThruTheAirTM is a trademark of Corintech Ltd. Ashford Mill, Station Road, Fordingbridge, Hampshire, SP6 1DZ, UK Issue 2 08/08/2022 Page 3 of 3