User Guide for Danfoss models including: AQ251486498741en-010607, E100 VX01X 281624 0030471, NovoCon S High Accuracy Actuator, NovoCon S, High Accuracy Actuator, Accuracy Actuator, Actuator
File Info : application/pdf, 2 Pages, 1.43MB
DocumentDocumentOperating Guide NovoCon® S - High Accuracy Actuator IP54 NovoCon® S / 73690900 IP54 IP54 DN 15 - 32 NO presetting! DN 15, 20 10 [100 %] DN 25, 32 100 % Manuel Calibration: Press button until two LED's are turned on, and then release again. DIP switch: Manual override: Adjust wheel Common ground shall be used for all devices on the same network. NovoCon® digital cable Red Black Green Power Common ground for power and bus signal wire ´+´ non-inverting signal wire White/green ´-´ inverting signal wire Actuator NovoCon® Actuator NovoCon® ChangeOver6 ChangeOver6 Energy Purple O-ring Blue O-ring NovoCon® Energy cable - PT1000 surface sensors NovoCon® I/O cable NovoCon® Energy cable - PT1000 immersed sensors Cable NovoCon® Temperature I/O Digital port Port for CO6 actuator or Energy cable, I/O cable, analog cable or voltage booster. Digital port NovoCon® analog cable Red Power 24V Black GND Grey Analog input or Flow sensor Blue Analog input ground Actuator NovoCon® ChangeOver6 Flexible Red Power 24V Black GND White CO6 Control signal Grey CO6 Feedback signal Red Black Blue Grey White Yellow Orange Red Black Blue Grey White Power 24V Power ground Ground T1, T2, V/mA input & V output signal V/mA input signal or Flow sensor V output signal T1, resistance input or Flow sensor T2, resistance input or Flow sensor Power 24V (in/out) Power ground (in/out) Ground T1, T2, V/mA input & V output signal V/mA input signal or Flow sensor V output signal T1 T2 © Danfoss | 2024.05 AQ251486498741en-010607 | 1 NovoCon® S - High Accuracy Actuator NovoCon®S 003Z8504 Actuator for AB-QM DN10-32 Control signal: BACnet MS/TP, Modbus RTU, 0-10V, 0-20mA Power: 24VAC/DC, 50/60 HZ Force: 90N. Stroke: 7 mm. Speed: 3-24s/mm Consumption: 3.3VA running. Standby 0.9W III IP54/40, -10T55 E100 VX01X 281624 0030471 6430 Nordborg, Denmark MADE IN SLOVENIA E100 VX01X 281624 0030471 Serial number and QR code can be removed from the NovoCon® S label and added to installation drawing. E100 VX01X 281624 0030471 Device Object Instance Number DIP Switch 1 2 3 4 5 6 7 8 9 10 ON OFF DIP Switches 1 to 7 are used to assign the MAC address manually. Default MAC address assignment method is Auto MAC addressing for BACnet MS/TP and DIP Switches for Modbus RTU. For termination of last unit on the field bus, turn DIP Switch 8 ON. Dip switch 9 is not used. Dip switch 10 is used to select between BACnet MS/TP (OFF=Default) and Modbus RTU (ON). When the protocol is changed on DIP Switch 10, a power cycle is required. Optional step (connecting flow sensor) Cable NovoCon® I/O 24 V GND GND AI AO T1 T2 Sharky FS 473 flow sensor Wire Description Brown Ground (-) White Volume pulse output (+) Initial configuration NovoCon® S Application mode: MSV:9 / 32810 Digital control (default), Analog control, CO6 mode, Inverted CO6 mode, CO6 without alarms, Inverted CO6 without alarms, Select Valve Type MSV:3 / 32802 (default AB-QM 4.0 ISO DN 15) Select application MSV:10 / 32811 Heating (default) Cooling Design Flow Rate AV:30 / 32796 Heating AV:31 / 32798 Cooling Activate calibration MSV:0 / 33284 state 2 or use manual calibration Analog CO6 mode, Analog inverted CO6 mode Safety Note To avoid injury and damage to persons and devices, it is absolutely necessary these instructions are carefully read and observed prior to assembly and commissioning. Necessary assembly, start-up, and maintenance work must be performed only by qualified, trained and authorised personnel. Switch off the power line before wiring the actuator. Safety Note Connect via safety isolating transformer. Galvanic separations shall be provided for segments crossing buildings. Safety Note If the NovoCon® S network is supplied with two or more AC power boosters, caution must be observed when disconnecting one of the transformers from the high voltage power line. As the NovoCons are connected in a daisy chain, there may be high voltage on the primary side of the disconnected power supply. Disconnect always both the primary and secondary side of the transformer. Firmware update We recommend to validate the firmware version before installation. The latest firmware can be downloaded at www.novocon.com by selecting the tab: Support files. The following information is provided with the product documentation or marked on the product: A) Purpose of control: Operating Control. B) Construction of control: Independently Mounted. C) Type 1 Action. D) Pollution Degree: 3. E) Impulse Voltage: 500 V. F) Type of movement: Linear. G) Mechanical and thermal ratings (ref. to Ratings section for more details). H) Main power supply for actuator and "Input control signal" shall be provided by the same SELV/Class 2 circuit. : UA: « » 04080, 80, / 168, 2 | © Danfoss | DCS-SGDPT/SI | 2024.05 73690900 / AQ251486498741en-010607