User Guide for unitech models including: RP901, Wireless UHF RFID Pocket Reader, UHF RFID Pocket Reader, Wireless Pocket Reader, Pocket Reader, Reader

RP901 QG - rev 2.1.ai

Shaw

RP901 QG - rev 2 2 (..>

Index of /uploads/images

RP901 QG - rev 2.1.ai


File Info : application/pdf, 8 Pages, 619.28KB

PDF preview unavailable. Download the PDF instead.

RP901 QG - rev 2 2 (2021 09 01)
because we care
For more detailed scanner setting, please go to www.ute.com to download the user manual and RFID utility.

RP901
Wireless UHF RFID Pocket Reader
Quick Guide

Version 2.2

FCC WARNING STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.
CANADIAN DOC STATEMENT
This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de las classe B prescrites dans le Réglement sur le brouillage radioélectrique édicté par les ministère des Communications du Canada.
CE MARKING AND EUROPEAN UNION COMPLIANCE
Testing for compliance to CE requirements was performed by an independent laboratory. The unit under test was found compliant with all the applicable Directives, 2004/108/EC and 2006/95/EC.
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
The WEEE directive places an obligation on all EU-based manufacturers and importers to take-back electronic products at the end of their useful life.
ROHS STATEMENT OF COMPLIANCE
This product is compliant to Directive 2002/95/EC.
NON-MODIFICATION STATEMENT
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

- 1 -

RoHS

WARNING AND CAUTION
1. Take any metals into contact with the terminals in connectors. 2. Use the scanner where any inflammable gases.
If following condition occur, immediately power off the host computer, disconnect the interface cable, and contact your nearest dealer. 1. Smoke, abnormal odors or noises come from the scanner. 2. Drop the scanner so as to affect the operation or damage its housing.

Do not do behavior below.

1. Put the scanner in places excessively high temperatures such as expose under direct sunlight.

2. Use the scanner in extremely humid area or drastic temperature changes.

3. Place the scanner in oily smoke or steam environment such as cooking range.

4. Be covered or wrapped up the scanner in bad-ventilated area such as under cloth or blanket.

5. Insert or drop foreign materials or water into scanning window or vents.

6. Using the scanner while hand is wet or damp.

Do Not

7. Use the scanner with anti-slip gloves containing plasticizer and chemicals or organic solvents such as benzene, thinner, insecticide etc

to clean the housing. Otherwise, it could not result fire and electrical

shock but housing may be broken and injured.

8. Scratch or modify the scanner and bend, twist, pull or heat its interface cable.

9. Put heavy objects on interface cable.

Do not stare the light source from the scanning window or do not point the scanning window at other people's eyes or eyesight may be damaged by direct exposure under the light.

Do not put the scanner on an unstable or inclined plane. The scanner may drop, creating injuries.

Once the interface cable is damaged such as exposed or broken copper wires, stop using immediately and contact your dealer. Otherwise, it could result fire or electrical shock.

- 2 -

OUT OF THE BOX

PWR1oPirc9ek0leet1sRseUaHdeFrRFID
2 Quick Guide

Wireless UHF RFID Pocket Reader

Quick Guide

USB Charger Cable

Wrist Strap

- 3 -

INTRODUCTION
Trigger Button Function Button
LED Indicator

Micro USB port
SPECIFICATIONS

Frequency Standard Read Range
Memory Housing Weight Profile/Interface Battery Life Charge Time Radio Radio Coverage Operating Temp

865 - 928 MHz (US/EU/JP/TW/CN)
EPC Gen2/ ISO 18000-6C Single Tag Mode: Up to 100cm
(Depends on the type of RFID tag and environment) Multiple Tag Mode: Less than 50cm (Depends on the type and quantity of RFID tag and environment)
2MB PC + ABS 103.5g (w/ battery) BT HID, BT SPP, USB HID, USB VCP 6000 scans 4 hours (fully charged) Bluetooth 2.1 + EDR (Class2) 10M/33ft. (line of sight) -10 to 50°C (14°F to 122°F)
- 4 -

BEEPER INDICATION

Single long beep

Power up

Single beep

Good read

Two beeps

i. Wireless connection

ii. The reader successfully enters or

exits configuration mode

Three beeps

Wireless disconnection

Three short beeps

The reader reads a tag while

disconnected.

Four beeps (Hi-Lo-Hi-Lo) Out of range/Poor connection

Five beeps

Low power

LED INDICATION

Off Flashing Blue Green for 2 sec Flashing Red Solid Red

Standby or Power off Disconnected or Discoverable Good Read Low power Charging

CHARGING THE BATTERY

1. Flip open the micro USB port on the reader. 2. Plug the micro USB connector into the port on the
reader and USB A connector into a USB port on the host PC or power adapter. 3. Please fully charge the reader for 4 hours (or until the red LED indicator turns off) before use.
- 5 -

READING RFID TAGS

Below figure shows the optimal orientation of reader and RFID Tag for reading.

RP901-43H810G: (For Japanese version)

RFID Tag

Reading Distance > 100cm
(*Single Tag Mode)
RP901-43A810G/33E810G/43T810G/43C810G:
RFID Tag
90° Reading Distance > 100cm
(*Single Tag Mode)

Reading distance may be impacted by the type of tag and environmental conditions. Above is based on Alien 964X Higgs-3 tag and tested in an office environment (25°C)
- 6 -

POWER UP
Press the Trigger Button for 2 seconds. The unit will emit one (1) long beep and light the LED red as confirmation that the reader has successfully powered up.

SHUT DOWN
METHOD 1: By default, the unit shuts down automatically after 5 minutes of inactivity.
METHOD 2: Using a needle or paper clip, press the Reset Button located at the bottom of the reader once. This will force a shut down.

Trigger Button Function Button

DISCONNECT/ CLEAR PAIRING RECORD
STEP 1: Remove/Forget the the "UHF RFID reader" from the Bluetooth device list on your host device.
STEP 2: Long press on the Function Button for 5 seconds without releasing. The unit will emit three (3) beeps and the blue LED will start flashing as confirmation that the reader is discoverable.

Reset Button
METHOD 3: Simply disconnect the battery from the reader. This will force a shut down as well.

- 7 -

- 8 -

GETTING CONNECTED Connecting to a PC/ Notebook

Connecting to an Apple iOS Device

1. Press and hold the Trigger Button for 2 seconds to power up the 1. Press and hold the Trigger Button for 2 seconds to power up the

unit, after which the blue indicator LED will flash continuously.

unit, after which the blue indicator LED will flash continuously.

2. Long press on the Function Button for 5 seconds without releasing 2. Long press on the Function Button for 5 seconds without releasing until 3 beeps. This ensures the previous pairing record is deleted. until 3 beeps. This ensures the previous pairing record is deleted.

3. Enter the PC/Notebook's Bluetooth application, and click "Add a Device".
4. In the Add a device window, double click "UHF RFID Reader" to connect.
5. When successfully connected the reader will emit two short beeps, and the blue LED indicator will shut off.

3. On the Apple iOS device, go to Settings > Bluetooth, and turn on Bluetooth.
4. In the discoverable devices list, select "UHF RFID Reader".
5. Upon establishing connection the reader will emit two short beeps and turn off its blue LED indicator. Also, the UHF RFID Reader will list as "Connected" in the Apple iOS device's Bluetooth devices list.

6. Launch a program that can accept HID keyboard input, such as Notepad. RFID Tag data read by the reader will output to that program.
- 9 -

6. Launch an app that can accept HID keyboard input, such as Notes. RFID Tag data read by reader will output to that app.
7. If a virtual keyboard is required, please press the Function Button once. At this moment the reader will emit one short beep, and the Apple iOS device's virtual keyboard will pop out.
- 10 -

GETTING CONNECTED

Connecting to an Android Device

1. Press and hold the Trigger Button for 2 seconds to power up the 7. If a virtual keyboard is required, please do the following:

unit, after which the blue indicator LED will flash continuously.

(1) Enter "Settings"

(2) Enter "Language & Input"

2. Long press on the Function Button for 5 seconds without releasing (3) Tap on "Default keyboard"

until 3 beeps. This ensures the previous pairing record is deleted. (4) Turn off "Physical keyboard", or turn on "On-screen keyboard"

and the Touch Keyboard will function properly again.

3. On the Android device, go to Settings > Bluetooth, and turn on

Bluetooth.

4. In the available devices list, select "UHF RFID Reader".
5. Upon establishing connection the reader will emit two short beeps and turn off its blue LED indicator. Also, the UHF RFID Reader will list as "Connected" in the Android device's Bluetooth devices list.

Slide to turn on/off

6. Launch an app that can accept HID keyboard input, such as ColorNotes. RFID Tag data read by reader will output to that app.

- 11 -

- 12 -

DEFAULT RFID SETTINGS

Operation Mode

= Trigger Mode

Read Mode

= Single-Tag Read

Session

= S0

Target

= Single Target

Tag Info

= EPC Code and TID

CRC Value

= Disable

Scan Period and Delay Time

Scan Period

= Disable

Delay Time

= Disable

Scheme and Filter

EPC Scheme Tag

= All

Accepted Filter

= Disable

Rejected Filter

= Disable

Affected Scheme Filter = SGTIN-96

RF Parameters

RF Output Power

= Level 5 (max)

Data Output Format

= Simple Cascade

Data Content

= Hexadecimal

Time Log Data

= Disable

RSSI Data

= Disable

EPC Scheme Data = Disable

EPC Code Data

= Enable

PC Data

= Disable

TID Data

= Enable

No Tag Message = Disable

- 13 -

RFID UTILITY
RFID Utility enables you to configure the reader with your PC/Laptop via USB connection. It is available for download from www.ute.com.
- 14 -



References

Acrobat Distiller 19.0 (Windows)