User Manual for Winsen models including: MH-Z19E Infrared CO2 Sensor Module, MH-Z19E, Infrared CO2 Sensor Module, CO2 Sensor Module, Sensor Module, Module
File Info : application/pdf, 6 Pages, 769.40KB
DocumentDocumentwww.winsen-sensor.com Infrared CO2 Sensor Module (Model: MH-Z19E) User's Manual (Version 1.1) Issue Date. 2023.03.29 Zhengzhou Winsen Electronics Technology Co., Ltd ISO9001 Certificated Company Leading gas sensing solutions supplier in China www.winsen-sensor.com Statement This manual's copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in database or retrieval system, also can't spread through electronic, copying, record ways. Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disassemble, change the components inside of the sensor, we shall not be responsible for the loss. The specific such as color, appearance, sizes &etc., please in kind prevail. We are devoting ourselves to products development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users' comments on optimized using way are welcome. Please keep the manual properly, in order to get help if you have questions during the usage in the future. Zhengzhou Winsen Electronics Technology CO., LTD. Leading gas sensing solutions supplier in China www.winsen-sensor.com MH-Z19E NDIR CO2 Module Profile MH-Z19E NDIR infrared gas module is a common type, small size sensor, pins/reversed pins type or terminal type, using non-dispersive infrared (NDIR) principle to detect the existence of CO2 in the air, with good selectivity, non-oxygen dependent and long life. Built-in temperature compensation; and it has UART output and PWM output. It is developed by the tight integration of mature infrared absorbing gas detection technology, precision optical circuit design and superior circuit design. Applications *HVAC refrigeration *Indoor air quality monitoring *Ventilation system *Air cleaner device *Smart home *School Main Features *High sensitivity, low power consumption *Good stability *Temperature compensation, excellent linear output *Multiple output modes: UART, PWM *Long lifespan *Anti-water vapor interference, anti-poisoning Fig1.Terminal Fig1.Pins/Reversed Pins Terminal Main parameters Table1. Model No. Detection Gas Working voltage Average current Peak current Interface level Detection Range Output signal Preheat time Refresh time Response Time Working temperature Working humidity Storage temperature Weight Lifespan MH-Z19E CO2 5.0±0.1V DC < 40mA (@5V power supply) 125mA (@5V power supply) 3.3 V (Compatible with 5V) 400~10000ppm(optional, see table2.) Serial Port (UART) (TTL level 3.3V) PWM 1 min 2 s T90 < 120 s -10 ~ 50 0 ~ 95% RH (No condensation) -20~60 5 g > 10 years Leading gas sensing solutions supplier in China www.winsen-sensor.com Detection range and accuracy Table2. Detection Gas Carbon Dioxide Formula CO2 Detection Range 400~2000ppm 400~5000ppm 400-10000ppm Resolution 1ppm Accuracy ± (50ppm+5% reading value) Dimensions (Pins/Reversed pins type) unmarked tolerance is ±0.2 Fig2. Pins connection type table3. Pin Vin GND PWM Hd Rx Tx Pin Definition Positive pole of power (Vin) Negative pole of power (GND) PWM HD(zero point calibration, low level lasting for over 7s is effective) UART(RXD)TTL Level data input UART(TXD)TTL Level data output Leading gas sensing solutions supplier in China Dimensions (Terminal type) www.winsen-sensor.com Terminal connection type Pin Terminal Pin Definition Pin 4 Vin Power In Pin 3 GND Pin 2 Reserved Pin 7 PWM HD(zero point calibration, low level Pin 1 lasting for over 7s is effective) Pin 5 UART(RXD) 0~3.3V data input Pin 6 UART(TXD) 0~3.3V data output Terminal Connection Version Cautions Please avoid the pressure of its optical chamber from any direction, during welding, installation, and use. When placed in small space, the space should be well ventilated, especially for diffusion window. The module should be away from heat, and avoid direct sunlight or other heat radiation. The module should be calibrated termly, the suggested period is no longer than 6 months. Do not use the sensor in the high dusty environment for long time. Leading gas sensing solutions supplier in China www.winsen-sensor.com To ensure the normal work, the power supply must be among 5.0V±0.1V DC rang, the power current must be not less than 150mA. Out of this range, it will result in the failure of the sensor. (The concentration output is low, or the sensor cannot work normally.) During the zero-point calibration procedure by manual or sending command, the sensor must work in stable gas environment (400ppm) for over 20 minutes. Forbid using wave soldering for the sensor. When soldering with soldering iron, set the temperature to be (350±5), and soldering time must be within 3 seconds. We suggest customers to use the way of soldering the socket and plugging/pulling the sensors for easier maintenance. Zhengzhou Winsen Electronics Technology Co., Ltd Add: No.299, Jinsuo Road, National Hi-Tech Zone, Zhengzhou 450001 China Tel: +86-371-67169097/67169670 Fax: +86-371-60932988 E-mail: sales@winsensor.com Website: www.winsen-sensor.com Leading gas sensing solutions supplier in China