Installation Guide for BATHOLOGY models including: 511 Sauna Color Bathing Experience, 511, Sauna Color Bathing Experience, Color Bathing Experience, Bathing Experience, Experience
8 INSTALLATION STEP 3 - ONTROL 1. At determined control location cut a 1-1/2” x 2-13/32 square hole to mount control. 2. Take the 25’ AT6 cable run from DMX driver and
File Info : application/pdf, 15 Pages, 1.12MB
DocumentDocumentS p e c t r u m 511 Sauna Color Bathing Experience Installation and Operation Manual SAFETY & WARNINGS PLEASE READ THIS MANUAL IN ITS ENTIRETY PRIOR TO INSTALLATION! 1. All wiring must be done in accordance with national electric code and local building codes by a certified electrician. 2. All electrical components such as driver, power supply, and control must be installed in a location protected from moisture, rain, and or inclement weather. 3. Please note the maximum temperature ratings of all components on page 4 Specifications. Components should not be installed where maximum temperature of component will be exceeded, doing so will void warranty. 4. Do not install Led lights directly above or within 20" of heat source. 5. Consider light placement carefully. Each Led light should be placed to avoid direct contact with the bathers eyes. 6. Prior to installation, consider the placement of the Light Control carefully, taking into account the location of electrical, plumbing, and other fixtures. 7. The Spectrum 511 control is designed for installation exterior of the Sauna Room, control is not rat- ed for installation inside Sauna Room. 8. The maximum light cable distance from Driver to farthest light is 100'. 9. All system components should be tested prior to final installation. 10. Always fully disconnect power from the system prior to making or disconnecting any connections. Electrical Requirements Always turn off the power at the breaker box before starting any electrical work. · A 120V AC electrical outlet is needed to power the lighting system. · Your electrician will determine the type of electrical outlet, box, and pip- ing to be used. · Improper voltage or connections will damage the components and void warranty. 2 PACKAGE CONTENTS DMX Driver / Receiver (qty. 1) RGB Control (qty. 1) Output Box (qty. 1) Brilliance LED Light (qty. 1) Power Supply (qty. 1) AC Power Cable (qty. 1) Led Light Mounting Template (qty. 1) 4-Port DC Splitter (qty. 1) 1FT CAT 6 Cable (qty. 2) 25FT CAT 6 Cable (qty. 2) 50FT DC Power Cable (qty. 1) Required Tools for Installation #2 Phillips Head Screwdriver Power Drill Flat Head Screwdriver 1-5/8" Hole Saw 3 SPECIFICATIONS DMX Driver Led Light Operating Voltage: 24V DC Operating Voltage: 24V DC Power Consumption: 4.2 - 12.6 watts per channel Power Consumption: 3 Watts Output Voltage: 12-36V DC Led Type: RGB Output Current: 350mA Constant Current Lumens: 88 Connections: Power In - DC Female Barrel Trim Finish: Stainless Steel DMX In/Out - RJ45 Cat6 Housing: Aluminum Led Out - RJ45 Cat6 Beam Angle: 120° - Frosted Lens Zones: 1 Zone RGB Lens Composition: Tempered Glass Operating Temp: -4°F - 122°F Connection: RJ45 Cat6 Dimensions: 7"L x 1.81"W x .82"H Rough-In Cutout: 1-5/8" Light Capacity: 6 (per Driver) Trim Dimensions: 2" Diameter, 18" Profile IP Rating: IP20 Body Dimensions: 1-15/35" Diameter Certifications: UL, CE. FCC, CRUus 1-7/8" Deep RGB Control Output Signal: Operating Voltage: DMX 24VDC Operating Temp: IP Rating: Certifications: 0°F - 230°F IP68 CE, ROHS Power Consumption: 500mA Material: Aluminum Housing / Glass Face Connections: Power In - DC Female Barrel DMX In - RJ45 Cat6 Cutout 1-5/8" Mounting: Double Sided Adhesive/Silicone Dimensions: 4.72"L x 3"W x .59"H Operating Temp: 32°F - 122°F Zones: 1 Zone RGB IP Rating: IP67 Certifications: CE Power Supply Input Voltage: Output Voltage: Rated Power: AC Current: DC Current: Operating Temp: IP Rating: Certifications: 120VA C 24V DC 90W 1.3A 3.75A -22°F - 158°F IP20 UL, CE, FCC 1-3/16" 1-15/35" 1/8" 2" 4 CONNECTION OVERVIEW 120VAC 1 - 6 Lights Setup Not Used POWER SUPPLY DC Splitter 50' DC Cable 25' Cat6 Cable GND D+ DGND D+ D- Link to Second Driver (second driver required for running more than 6 lights) Control Installed Exterior Sauna Room R G B 0-5 0-9 0-9 Y W 25' Cat6 Cable C P B S 1 2 3 4 5 OUTPU T B6 B5 B4 B3 B2 B1 A1 A2 A3 A4 A5 A6 INPUT DMX IN 12-36VDC DMX OUT B A For 1-6 Lights Connect to Port A 1' Cat6 Cable X1 Terminator (see pages 8-9 for use) Figure #1 CONNECTION OVERVIEW 7 - 12 Lights Setup - Requires purchase of second driver - Not Used POWER SUPPLY DC Splitter INPUT DMX IN 12-36VDC DMX OUT GND D+ DGND D+ D- GND D+ DGND D+ D- 25' Cat6 Cable Control Installed Exterior Sauna Room INPUT DMX IN 12-36VDC DMX OUT R G OUTPU T B 0-5 0-9 0-9 Y W R G OUTPU T B 0-5 0-9 0-9 Y W 25' Cat6 Cable 50' DC Cable C P B S 1 2 3 4 6 A1 A2 A3 A4 A5 A6 B A B6 B5 B4 B3 B2 B1 1' Cat6 Cable X2 25' Cat6 Cable INSTALLATION STEP 1 - DMX DRIVER 1. At determined location mount DMX driver. Note: DMX driver must be installed in a dry accessible location or inside a waterproof electrical enclosure. 2. Take Output box and mount next to DMX driver. See Figure 1 3. Route 50' dc power cable from DMX driver location to control location. Note: Male end of dc cable connects to control. 4. Route 25' CAT6 cable from DMX driver location to control location 5. At DMX driver take 25' CAT6 cable ran to control and plug into DMX in lead on DMX driver. 6. Route 25' CAT6 cable from Output box to light location. Repeat this step for each additional light. Note: Refer to pages 9-12 for Output Box connections. 7. Take 4 port DC splitter and connect one male end to power in on DMX driver. Connect second male end to 50' dc power cable for control. 8. Take 1' Cat6 cable and connect one end to light out lead on DMX driver and other end to in port A of Output box. Note: Each lead/driver handles 6 lights max. For more than 6 lights a separate driver kit must be purchased. 9. After checking and verifying all connections at driver and output box proceed to Led light installation. STEP 2 - BRILLIANCE LED LIGHTS 1. Locate mounting plate and install at each light location by fastening plate to ceiling joist or wall stud. See figure 3 2. After finished material is installed use the 1-5/8" hole saw and power drill, drill a hole for each light. 3. After drilling hole ensure any installation is pushed to the side to maintain at least 2" clearance from top and sides of light. 4. Take female RJ45 connector from light and plug into RJ45 cable from DMX driver. 5. Run a 1/8" bead of silicone around edge of light for wet applications. See figure 3 6. Take light and push up into opening until trim is flush with surface. 7. Back at DMX driver plug Cat 6 cables from each light into 12 port splitter box. Note: Repeat above steps for each additional light. Note: Refer to pages 9-12 for output box connections and setup. 2" Clearance from insulation above and around fixture 16" Location Template Joist 1" Ceiling / Wall Material 1/8" bead of silicone for wet environments Figure #3 7 INSTALLATION STEP 3 - CONTROL 1. At determined control location cut a 1-1/2" x 213/32 square hole to mount control. 2. Take the 25' CAT6 cable run from DMX driver and plug into RJ45 pigtail on control. 3. Take 50' DC Power Cable and plug into DC pigtail on control. 4. Remove backing off double sided adhesive. 5. Run a continuous bead of silicone on back side of control. 6. Press control onto wall ensuring level and secure. Wipe away any access silicone. DMX / Power Connections Figure #4 Adhesive Tape Power On / Off - Press and hold for 2 seconds Color Button - Press and hold for 2 seconds, enables color mode Pre-Programmed Scenes - Press and hold for 2 seconds, use button 1-4 to select scenes Color Wheel - Press and drag to cycle through colors Figure #5 C P B S 1 2 3 4 Brightness - Press and hold for 2 seconds, enables brightness mode. Use Color wheel to increase decrease brightness 1 - 4 - Colors and Scenes 1 - Red / 2 - Green / 3 - Blue / 4 - White Note: S button note used STEP 4 - STARTUP & TESTING 1. After completing all installation steps take 4 port DC splitter and plug Female end into Male end from power supply. 2. Plug power supply into 120VAC outlet. 3. Verify DMX driver lights up and screen displays 001 Note: If driver is not displaying 001 or any other number upon applying power proceed to troubleshooting steps on page #13. 4. At control press power button to turn on lights. Verify all lights in room come on and cycle through colors. If you encounter any issues during startup refence page # 13 for troubleshooting steps. 8 OUTPUT BOX SETTINGS Terminator Note: Input A will handle up to 6 lights. 2 Lights A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) Terminator position 1 2 ON: 1,2,3,4 OFF: 5,6,7,8,9 3 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 INPU T B A DIP Switch A 12 34567 89 ON OFF Terminator 3 Lights A INPU T A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 OFF: 1,2,3,4,9 6 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 B DIP Switch A 12 34567 89 ON OFF 4 Lights A INPU T A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 B DIP Switch A 12 34567 89 ON OFF 9 OUTPUT BOX SETTINGS Terminator Note: Input A will handle up to 6 lights. 5 Lights A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 INPU T B A DIP Switch 5-6 Lights 12 34567 89 ON OFF A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 INPU T B A 6 Lights DIP Switch 5-6 Lights 12 34567 89 ON OFF 10 OUTPUT BOX SETTINGS Note: Input B will handle up to 6 lights. 7 Lights A INPU T A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 B Terminator 8 Lights A INPU T A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 B Terminator DIP Switch A 12 34 567 89 ON OFF DIP Switch B 12 34567 89 ON OFF 9 Lights A INPU T A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 B Terminator DIP Switch A 12 34567 89 ON OFF 11 OUTPUT BOX SETTINGS Note: Input B will handle up to 6 lights. 10 Lights A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 INPU T B A DIP Switch B 12 34567 89 ON OFF 11 Lights A INPU T A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 B Terminator DIP Switch B 12 34567 89 ON OFF 12 Lights A INPU T A6 A5 A4 A3 A2 A1 OUTPUT ON A 1 2 3 4 5 6 7 8 9 ON ON DIP 12 3 4 5 6 78 9 ON B 1 2 3 4 5 6 7 8 9 Lights DIP Switch (A/B) 1 2 ON: 1,2,3,4 3 OFF: 5,6,7,8,9 4 5 ON: 5,6,7,8 6 OFF: 1,2,3,4,9 Terminator position (A/B) 2,3,4 (A/B) 3,4 (A/B) 4 (A/B) 6 OUTPUT B6 B5 B4 B3 B2 B1 B DIP Switch B 12 34567 89 ON OFF 12 TROUBLESHOOTING No Power · Verify electrical outlet has proper voltage. · Check that connections on DC splitter secure and connected. Power but lights not turning on · Check DMX CAT6 cable from driver to control is secure and connected. · Check DC power cable from driver to control is secure and connected. · Check 1' CAT6 cable to output box is secure and connected on both ends. · Check all 25' CAT6 cables to lights are secure and connected. · Verify correct setup on output box for the amount of lights. See pages 9-12 · Verify each light functions by testing directly to driver independently. Note: If one light goes bad with multiple lights all lights will shut off as lights are in series. Lights on no function from Control · Check DMX CAT6 connections at control and driver are secure and connected. · Check DC power cable from driver to control is secure and connected. DMX Driver Menu Settings To access menus to verify or troubleshoot follow steps bellow, see figure 5 for reference. Channel Menu 1. Press and hold buttons #2 and #3 at the same time for 3-5 seconds, screen will flash. 2. Press button #1 until 1ch displays. 3. Press and hold any button for 3-5 seconds to exit and save setting. Mode Menu 1. Press and hold buttons #1 and #2 at the same time for 3-5 seconds, screen will flash. 2. Press button #3 until ru2 displays. 3. Press and hold any button for 3-5 seconds to exit and save setting. DMX Address Menu 1. Press and hold button #1 for 3-5 seconds, screen will flash. 2. Press button #1, #2, and #3 until 001 displays. 3. Press and hold any button for 3-5 seconds to exit and save setting. PWM Frequency Menu 1. Press and hold button #1 and #3 for 3-5 seconds, screen will flash and display P - c. 2. Press button #1, until 2 displays. Press button #3 until 2 displays. Screen should display 2 - 2 3. Press and hold any button for 3-5 seconds to exit and save setting. 13 Figure #5 Channel - 1 Mode - ru2 DMX Address - 001 PWM Frequency - 2-2 0-5 0-9 0-9 1 2 3 REPLACEMENT PARTS Description DMX Driver 350mA Touch Control RGB LED Light, RGB, Frosted Power Supply 90 watt Output Box AC Power Cord 4 Port DC Splitter 50' DC Power Cable RJ45 Pigtail Cable DC Pigtail Cable 25' CAT 6 Cable 1' CAT 6 Cable Mounting Template Driver Kit for Additional Lights 7-12 (does not come with lights) Part Number BP031122 SPECTRUM097 SPECTRUM102 BP031137 BP031140 BP031132 BP031138 BP031134 BP031141 BP031143 BP031129 BP031128 SPECTRUM-68-TEMP SPECTRUM201 14 © 2024 Bathing Brands, Inc. 15 Spectrum511 REV - 2.0-02/2024Microsoft Publisher for Microsoft 365