INSTRUCTION MANUAL
OIL-FREE SCROLL VERTICAL PUMP-MOTOR ASSEMBLY
SLVB-5
Thank you for purchasing our oil-free scroll air compressor.
Before operation, be sure to read this instruction manual thoroughly for safe and efficient use for a long operating lifetime.
After reading it, store in a convenient place for immediate and future reading.
Before use, be sure to fill in the blank spaces below for future repair and after service. MODEL
SERIAL No.
Purchased from Date of purchase
Date of use
1

Important information and Safety precautions
 Important information Read all important information and safety precautions before use. The operator shall be fully knowledgeable of the requirements stated within this instruction manual, including important warnings, cautions and operation. Read manual before performing any maintenance.
Keep this booklet in an appropriate place for immediate reference.

· Indications of warnings and cautions
WARNING May cause injury or death. CAUTION May result in injury or property damage.

· Examples of warnings and cautions
May cause electric shock. Do not touch. Must be grounded.
 Supplier is not responsible for any injuries or damages caused by disregard of warnings, operating instruction specifications or maintenance schedules.

Important
l@;

Indicates important notices you must observe. They are helpful to achieve top performance and functions of the equipment.

2

Important information and Safety precautions

 Safety precautions

WARNING

Install in a safe area.
To prevent a fire or explosion, install in an area free of flammable gases or organic solvents.
Never install outdoors.
To prevent fire or electric shock, never install outdoors.
Turn off the main electric source.
To prevent electric shock or serious injury, always turn off the main electric source before inspecting or servicing the unit.

Ask a qualified electrician.
Only a qualified electrician should perform maintenance on the unit.

Be sure to ground.
Unit must be grounded to prevent electric shock.
Never use to compress anything other than air.
Unit must only be used to compress air.
Do not use with respiratory equipment, which could cause serious injury or death.

3

Important information and Safety precautions
WARNING
Not for use as life support.
Serious bodily injury and/or death may occur. Unit must only be used to compress air.
Do not touch.
Keep hands and fingers away from fans, pulleys and belts while the power is on. Serious injury, including entanglement of fingers or hands can occur.
Release pressure.
Release pressure from unit before conducting maintenance and/or inspection. Failure to do so may cause serious injury.
Conduct maintenance and inspection.
Conduct maintenance and inspection according to this manual to prevent unit failure.
4

Important information and Safety precautions
CAUTION
Use at ambient temperatures of 36°F to 104°F.
Drain will freeze at less than 36°F and will cause unit failure. Using over 104°F will cause a shorter lifespan or unit damage.
Use in an area free of dirt and dust.
Failure to do so may result in equipment failure.
Use in an area free of corrosive gas.
Failure to do so may result in equipment failure.
Only qualified personnel should perform repairs to prevent electric shock or fire.
Keep Away.
Keep away from the compressor while it is operating and allow it to cool before servicing. Failure to do so may result in serious burns and or bodily harm.
Never alter the compressor
Fire and or electric shock may occur if unit is altered and warranty will be void.
Use genuine parts
Be sure to use only genuine parts during maintenance. Failure to do so may result in equipment failure.
5

Contents
Important information and Safety precautions Important information ---------------------------------- 2 Safety precautions --------------------------------------- 3 Contents ---------------------------------------------------- 6 Installation Precaution about installation ---------------------------- 7 Installation space ---------------------------------------- 8 Ventilation ------------------------------------------------- 8 Test operation Operation -------------------------------------------------- 9 Maintenance and inspection Pump-Motor Assembly maintenance standards ----- 10 How to carry out maintenance ---------------------------- 11 Troubleshooting Guide -------------------------------------- 12 Specifications Compressor specifications ---------------------------------- 13 Appendix Outer dimensions --------------------------------------------- 14 Warranty Warranty -------------------------------------------------------- 15
6

Installation
 Precautions about installation
WARNING!
Do not use in an area which is exposed to rain, steam or high humidity. High humidity can cause electric shock or fire. Do not install in an area with corrosive gas (ammonia, acid, salinity, ozone gas and sulfur dioxide) preventing a shorter lifespan of the unit.
WARNING!
To prevent a fire or explosion, install in an area free of flammable gases or organic solvents.
Ambient temperature
Use at ambient temperatures of 36°F to 104°F. Using at less than 36°F will cause unit failure or freezing.
CAUTION!
Install this product on a level floor to prevent vibration and noise, causing damage to the unit.
CAUTION!
Install in an area which is free of dust. Dust can cause increased temperature and wear, resulting in a shorter lifespan and/or unit failure.
7

Installation

 Installation space
Secure the space around the compressor for safe inspection and maintenance.

Installation space

(inch)

Above

24

Front side

40

Other Sides

20

 Ventilation
When using in an enclosed room, install a fan for ventilation.
Model SLVB-5

British Thermal Unit (BTU) 12800

8

Test operation

 Operation
 Preparation (1) Make sure all safety warnings, labels, and instructions have been read and understood before continuing. (2) Make sure any shipping materials, brackets, etc. are removed. (3) Check that the electric power source and ground have been firmly connected (4) Make sure all pressure connections are tight.

 Operation and check pressure increase (1) Switch the electric source breaker on. (2) Be sure the pressure increases when the compressor starts. (3) Check that the compressor operates without excessive vibration, unusual noises or leaks.

 Check maximum control pressure Operate the unit while the ball valve of the air receiver is closed. Be sure the compressor stops at the pressure shown below.

Voltage 208V 230V

Max. pressure (psi) 100 115

 Stop Turn off unit to stop the compressor. After the test operation ends, open the stop valve of the air outlet.

9

Maintenance and inspection

Carry out the following maintenance and inspection items according to the schedule below. This interval is based on conditions where ambient temperature is at around 86°F. If your location is warmer or running condition is severe, maintain at a shorter period. During warmer conditions, shorten the period approximately 30 % from our recommendation at every 9°F. The maintenance time differs from guarantee period.

 Pump-Motor Assembly maintenance standards

Inspect and check operational hours or number of years, whichever comes first.

Items

Contents

Operational

hours

Daily

Period

Maintenance time
Every Every Every Every Every Every 400hrs, 2,500hrs, 5,000hrs, 10,000hrs 20,000hrs 30,000hrs Every Every Every Every Every Every 2 months 1 year 2 years 4 years 8 years 12years

Remarks

Abnormal sound/ vibration Intake filter
Belt

Inspect, replace









Initial



only

Motor insulation

Check insulation

Motor

Inspect, replace

Pulley

Check groove.

After cooler

Clean outside

O rings

Replace

Air end seal parts, Re-grease

Inspect, replace

Air end fan FSOS fins

Clean

Air end

Replace



   


Replace when it is dirty. No looseness, no abnormal sound Replace if abnormal.
Replace if abnormal. Replace if abnormal.
Use Iwata genuine grease.



Replace when it is dirty.



 Inspect,  Replace  Consult with distributor who sold it to you. Air intake filters are not covered under warranty. You may want to keep extra filters on hand.

10

Maintenance and inspection

 How to carry out maintenance · Intake filter Blow dust off the filter with an air gun and replace if it is dirty. · Belt tension If the V belt makes a slipping sound at the startup, due to decrease of V belt tension, readjust the belt tension or replace it. If the belt tension is less than the figure in the chart below, adjust the belt tension again. An exclusive tool is necessary to measure belt tension. Ask our distributor to readjust belt tension when needed.

Model

Readjustment standard load / Hz

Readjustment target load / Hz Tolerance ±5

Replacement new belt target load / Hz Tolerance ±5

SLVB-5

75

98

105

11

Troubleshooting guide

If you have any problems, please refer to the below chart. ( * ) marked items may be difficult to remedy and require technical support. Please contact distributor for assistance.

Problem

Cause

Compressor unit does not start

Electric source is not ON. Electric source is not connected correctly.

Power is at supply Overload relay has tripped

connection and

Wrong or low voltage

compressor does not Starter has failed

start

Motor has failed

Drive belts came off or too loose

Clogged intake filter element

Compressor is running

but will not make

Discharge air is leaking

pressure

Pump has failed

Pump running in the wrong

direction

Excessive noise or vibration

Drive belt has flipped or slipped Motor has failed Pump has failed

Ambient temperature is high

Compressor running hot

Pump running at high pressure

Clogged intake filter element

Pump has failed

Motor overload has tripped

Motor has failed Improper wiring Wrong overload setting

Low voltage

Corrective action Turn on electric source
Connect it correctly
See last entry of Troubleshooting guide Inspect incoming power supply and unit power rating. Inspect, repair or replace contactor assembly * Inspect, repair or replace motor * Inspect, tighten or replace drive belts * Clean or replace intake filter element
Inspect and repair
Inspect, repair or replace pump * Correct power connections
Inspect, repair or replace drive belt * Inspect, repair or replace motor* Inspect, repair or replace pump Be sure not to exceed above 104 degree F Check tank pressure and pump outlet are not obstructed Clean or replace intake filter element Inspect, repair or replace pump * Inspect, repair or replace motor* Inspect and rewire * Check setting of overload relay * Check incoming power supply

12

Specifications

 Pump-Motor Assembly specifications

Compressor

Item Pump model

Model

Max Working pressure (psi)

Air delivery (cfm) Driving system
Discharge air temperature (°F)

Air outlet

Operating voltage

SLVB-5
SL-165E-US 100 psi @ 208V 115 psi @ 230V
*1 14.8 V-belt
Ambient temperature + less than 342 ½" JIC
Single Phase 208-230V, 60Hz

Others Motor

Output (HP)

5

Dimensions (L × W × H) (inch)

*2 17 x 20 x 26

Approx. mass (Lbs.)

190

Note *1) Air delivery means average discharge air volume at 115 psi (maximum pressure) converted into atmospheric pressure. It is not a warranted figure. *2) Dimensions are outer dimensions excluding extruding parts.

13

Appendix
 Outer dimensions
14

Warranty
 Warranty and Remedies
(a) General. Anest Iwata - Air Engineering warrants each Compressor System, Compressor Air-End, or Anest Iwata branded accessory (collectively "products", individually each a "product") to be free from defects in material and workmanship ("Defects") at the date of shipment. EXCEPT AS SET FORTH BELOW, NO OTHER WARRANTY, WHEATHER EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABLILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF SUCH PRODUCTS. TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. All claims under this warranty must be made in writing and delivered to Anest Iwata Air Engineering, or such claim shall be barred. Upon timely receipt of a claim, Anest Iwata Air Engineering shall inspect the product claimed to have a defect, and Anest Iwata Air Engineering shall repair, or, at its option, replace, free of charge, any product which it determines to have had a defect at the time of shipment from Anest Iwata Air Engineering; provided, however, that if circumstances are such as to preclude the remedying of defect by repair or replacement, Anest Iwata Air Engineering shall, upon return of the product, refund to buyer any part of the purchase price of such products paid to Anest Iwata Air Engineering. Freight for the returning products to Anest Iwata Air Engineering for inspection shall be paid by buyer. The warranties and remedies herein are the sole and exclusive remedy for any breach of warranty or for any other claim based on any defect, or non-performance of the products, whether based upon contract, warranty or negligence.
(b) Initial period of warranty ­ Parts and Labor. Anest Iwata Air Engineering warrants and represents all products shall be free from defects for the first twelve (12) months from the date of shipment by Anest Iwata Air Engineering, or five thousand (5,000) hours of use, whichever occurs first. During such warranty period, Anest Iwata Air Engineering shall be fully liable for all defects in the products (the "product defects"), i.e., all costs of repair or replacement, which may include "in and out" charges, so long as the products are located in the continental United States, and the products are reasonably located and accessible by service personnel for removal. "In and out" charges include the costs of removing a product from buyer's equipment for repair or replacement.
(c) Coverage. The above mentioned warranty applies to Anest Iwata Air Engineering manufactured units or systems only. (d) Exceptions. Notwithstanding anything to the contrary herein, Anest Iwata Air Engineering shall have no warranty obligations with respect to products:
(i) That have not been installed in accordance with Anest Iwata Air Engineering's Written specifications and instructions; (ii) That have not been maintained in accordance with Anest Iwata Air Engineering's written instructions; (iii) that have been materially modified without the prior written approval of Anest Iwata Air Engineering; or (iv) That experience failures resulting from operation, either intentional or otherwise, in excess of rated capacities or in an otherwise improper manner. (e) The warranty provided herein shall not apply to: (i) any defects arising from corrosion, abrasion, use of insoluble lubricants, or negligent attendance to or faulty operation of the products; (ii) ordinary wear and tear of the products; or (iii) defects arising from abnormal conditions of temperature, dirt or corrosive matter; (iv) any OEM component which is shipped by Anest Iwata Air Engineering with the original manufacturer's warranty, which shall be the sole applicable warranty for such component. Limitation of liability. TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, NOT WITHSTANDING ANYTHING TO THE CONTRARY HEREIN, UNDER NO CIRCUMSTANCES SHALL ANEST IWATA AIR ENGINEERING BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTAL, PUNITIVE, SPECULATIVE OR INDIRECT LOSSES OR DAMAGES WHAT SO EVER ARISING OUT OF OR IN ANY WAY RELATED TO ANY OF THE PRODUCTS OR GOODS SOLD OR AGREED TO BE SOLD BY ANEST IWATA AIR ENGINEERING TO BUYER. TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, ANEST IWATA AIR ENGINEERING'S LIABLITY IN ALL EVENTS IS LIMITED TO AND SHALL NOT EXCEED THE PURCHASE PRICE PAID. Warranty Disclaimer. Anest Iwata Air Engineering has made a diligent effort to illustrate and describe the products in this literature accurately; however, such illustrations and descriptions are for the sole purpose of identification, and do not express or imply a warranty that the products are merchantable, or fit for a particular purpose, or that the products will necessarily conform to the illustrations or descriptions. Product Suitability. Many jurisdictions have codes and regulations governing sales, construction, installation, and/or use of products for certain purposes, which may vary from those in neighboring areas. While Anest Iwata Air Engineering attempts to assure that its products comply with such codes, it cannot guarantee compliance, and cannot be responsible for how the product is installed or used. Before purchase and use of a product, please review the product applications, and national and local codes and regulations, and be sure that the product, installation, and use will comply with them. Claims. Claims pertaining to the products, with the exception of warranty claims, must be filed with Anest Iwata Air Engineering within 6 months of the invoice date, or they will not be honored. Prices, discounts, and terms are subject to change without notice or as stipulated in specific product quotations. All agreements are contingent upon strikes, accidents, or other causes beyond our control. All shipments are carefully inspected and counted before leaving the factory. Please inspect carefully any receipt of products noting any discrepancy or damage on the carrier's freight bill at the time of delivery. Discrepancies or damage which obviously occurred in transit are the carrier's responsibility and related claims should be made promptly directly to the carrier. Returned products will not be accepted without prior written authorization by Anest Iwata Air Engineering and deductions from invoices for shortage or damage claims will not be allowed. UNLESS OTHERWISE AGREED TO IN WRITING, THESE TERMS AND CONDITIONS WILL CONTROL IN ANY TRANSACTION WITH ANEST IWATA AIR ENGINEERING Any different or conflicting terms as may appear on any order form now or later submitted by the buyer. All orders are subject to acceptance by Anest Iwata Air Engineering. ANEST IWATA Air Engineering, 9525 Glades Drive, West Chester, Ohio 45069 USA 800-440-0282
15

16


Microsoft Word for Office 365