User Manual for AMPROBE models including: 5XP-A, 15XP-B, 35XP-A, 5XP-A Compact Digital Multimeter, 5XP-A, Compact Digital Multimeter, Digital Multimeter, Multimeter
Aug 2, 2024 — Designed for electronics engineers and field service technicians, the 15XP-B features TTL logic test for digital circuits ... user manual, test leads.
File Info : application/pdf, 2 Pages, 376.68KB
DocumentDocument5XP-A, 15XP-B, 35XP-A Compact Digital Multimeter Series Superior features and accuracy in a compact size 5XP-A Digital Multimeter with non-contact voltage detection 15XP-B Digital Multimeter with non-contact voltage detection 35XP-A Digital Multimeter with temperature Residential, commercial multimeter The right choice for residential, commercial and general troubleshooting applications. The 5XP-A has unique features such as VolTectTM non-contact voltage (NVC) detection and our exclusive Magne-GripTM holster that frees both hands for work. · 27 ranges/10 functions · Battery load test with 1.5 V and 9 V capabilities · MinMax record minimum and maximum values · Magne-GripTM holster holder with magnetic hanging strap frees both hands for work · VolTectTM non-contact voltage detection All Amprobe tools, including the Amprobe XP series, are rigorously tested for safety, accuracy, reliability, and ruggedness in our state-ofthe-art test lab. In addition, Amprobe products that measure electricity are listed by a 3rd party safety lab, either UL or CSA. This system assures that Amprobe products meet or exceed safety regulations and will perform in a tough, professional environment for many years to come. Commercial, industrial multimeter Designed for electronics engineers and field service technicians, the 15XP-B features TTL logic test for digital circuits, diode test for component level troubleshooting, a special 2000 M measurement range, and an integrated tilt stand for convenience on the bench. · Autoranging display for faster measurements · TTL logic test for digital circuits · Integrated tilt stand for hands free use · Diode test for component level troubleshooting · Data Hold freezes display to "hold" measurement reading · 600V AC / 600V DC--highest voltage rating in this size of meter · Special 2000 M measurement range · VolTectTM non-contact voltage detection HVAC, electrical industrial multimeter The compact, full-featured 35XP-A offers all the right features for HVAC, electrical and plant maintenance. It measures temperature, plus capacitance for motor run/ start test, and offers 0.1 A resolution for flame sensor testing. · Temperature measurement capability to 1000 °C/1832 °F (Type K thermocouple included) · 600 V AC/600 V DC - highest voltage rating in this class of meter · Capacitance for motor run/start test · 0.1 A resolution for flame sensor testing · Frequency to 1 MHz · Resistance to 40 M · Data Hold freezes display to "hold" measurement reading · Auto power-off · Low battery Indicator · Magne-GripTM holster holder with magnetic hanging strap frees both hands for work · VolTectTM non-contact voltage detection ©2016, 2024 Amprobe® For detailed specifications and ordering go to amprobe.com 240526-en Detailed Specifications Features 5XP-A Safety Rating CAT II 600 V, CAT III 300 V AC Voltage Range: 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 600 V Accuracy: ± (1.5 % rdg + 5 dgts) DC Voltage AC Current DC Current Voltage resolution Input impedance Overload protection Current resolution Input protection Burden voltage Resistance Range: 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 600 V Accuracy: ± (1.0 % rdg + 1 dgt) Range: 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA Accuracy: ± (2.0 % rdg + 5 dgts) Range: 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA Accuracy: ± (1.5 % rdg + 1 dgt) 10 M 200 mV: 600 V dc or 600 V ac rms (3 minutes) All other ranges: 600 V dc or 600 V ac rms 300 mV max. (1 V max. on 200 mA range) Range: 200.0 , 2.000 k, 20.00 k, 200.0 k, 2.000 M, 20.00 M, 2 M, 20 M Accuracy: ± (1.0 % rdg + 4 dgts), ± (1.5 % rdg + 4 dgts), ± (2.0 % rdg + 5 dgts) Capacitance Continuity Beeper 15XP-B CAT III 600 V 35XP-A CAT II 600 V, CAT III 300 V Range: 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 600 V Accuracy: ± (1.5 % rdg + 5 dgts) Range: 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V (45 Hz to 500 Hz) Accuracy: ± (1.5 % rdg + 5 dgts) Range: 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 600 V Accuracy: ± (1.0 % rdg + 1 dgt) Range: 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA Accuracy: (1.5 % rdg + 5 dgt) 2A, ± (2.5 % rdg + 5 dgt) Range: 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA Accuracy: ± (1.0 % rdg + 1 dgt) 2A, ± (2.0 % rdg + 3 dgt) 100 µV 400 mV: >100 M; 4 V: 10 M; 40 V to 1000 V: 9.1 M Range: 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V Accuracy: ± (0.5 % rdg + 1 dgt) Range: 400.0 µA, 4.000 µA, 40.00 mA, 400.0 mA, 2 A (45 Hz to 500 Hz) Accuracy: ± (1.5 % rdg + 5 dgts), ± (2.5 % rdg + 5 dgts) Range: 400.0 µA, 4.000 µA, 40.00 mA, 400.0 mA, 2 A Accuracy: ± (1.0 % rdg + 2 dgt), ± (2.0 % rdg + 3 dgts) 400 mV: >100 M ; 4 V: 10 M ; 40 V to 600 V: 9.1 M 600 V dc or 600 V ac rms 0.1 µA 2 A/1000 V fast blow ceramic fuse, 6.3 mm x 32 mm on A input 500 mV max. (2 V max. on 2 mA, 200 mA ranges) 500 mV max. (2 V max. on 4 mA, 400 mA ranges) Range: 200.0 , 2.000 k, 20.00 k, 200.0 k, 2.000 M, 20.00 M, 2000 M Accuracy: ± (1.0 % rdg + 4 dgts) 2000 M, ± {5.0 % (rdg -10 dgt) +20 dgt} Range: 40.00 k, 400.0 k, 4.000 M. 40.00 M Accuracy: ± (1.0 % rdg + 4 dgts), ± (3.0 % rdg + 5 dgts) Range: 4.000 nF, 40.00 nF, 4.000 µF, 40.00 µF, 400.0 µF, 4.000 mF Accuracy: ± (5.0 % rdg + 30 dgts) ± (5.0 % rdg + 5 dgts) ± (5.0 % rdg + 15 dgts) Audible Indication: Less than 25 Response Time: 100 ms Overload Protection: 600 V DC or 600 V AC rms Temperature* (Type K thermocouple) *K-type thermocouple accuracy tolerances not included Range: -4°F to 1832°F, (-20°C to 1000°C), -4 °F to 50 °F (-20 °C to 10 °C), 50 °F to 400 °F (10 °C to 200 °C), 400 °F to 1832 °F (200 °C to 1000 °C) Accuracy: ± 2.0 % rdg + 8 °F, ± (2.0 % rdg + 4 °C), ± 1.0 % rdg + 6 °F, ± (1.0 % rdg + 3 °C) ± 3.0 % rdg + 4 °F, ± (3.0 % rdg + 2 °C) Frequency Diode Test Logic Test VolTectTM Non-Contact Voltage Detection Auto Power Off Low Battery Indicator General Specifications Display Polarity Overrange Zero Measurement Rate Range: 1.0 mA (approximate) Accuracy: ±(1.5 % rdg + 3 dgts) Range: 1.2 mA (approximate) Accuracy: ± (1.5 % rdg + 3 dgts) TTL, 20 MHz Range: 4.000 kHz, 40.00 kHz, 400.0 kHz, 1 MHz Accuracy: ± (0.1 % rdg + 3 dgts) Range: 1.2 mA (approximate) Accuracy: ± (1.5 % rdg + 3 dgts) Sense voltage 70 V AC to 600 V AC (50 Hz to 60 Hz) beeper chirps and big bright red LED comes on, works on all ranges · · · · · · 3-1/2 digit LCD max reading 1999 Automatic, positive implied, negative polarity indication (OL) or (-OL) is displayed Automatic 2.5 times per second, nominal 2 times per second, nominal 3-3/4 digit LCD max reading 3999 Automatic 2 times per second, nominal Operating Environment 0 °C to 50 °C at <70 % R.H. Storage Temperature Accuracy -20 °C to 60 °C, 0 to 80 % R.H. without battery 23 °C ± 5 °C, <75 % relative humidity Temperature Coefficient 0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C) Altitude Power Battery Life Dimensions (H x W x D) Weight 155 mm x 72 mm x 32 mm (6.1 in x 2.8 in x 1.3 in) 2000 m (6561.7 ft) Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 200 hours typical with carbon-zinc, 400 hours typical with alkaline 155 mm x 72 mm x 32 mm (6.1 x 2.83 x 1.26 IN) Approx. 210 g (7.4 oz) including battery Included Accessories: Carrying case, Magne-GripTM holder with hanging strap, user manual, test leads 155 mm x 72 mm x 32 mm (6.1 in x 2.8 in x 1.3 in) ©2016, 2024 Amprobe® For detailed specifications and ordering go to amprobe.com 240526-en