Instruction Manual for HYTRONIK models including: DUAL Surface Mount Dual Sense Trailing Edge Sensor HIM16, DUAL Surface Mount Sensor, Dual Sense Trailing Edge Sensor, HIM16 Sensor, Sensor
HIM16 Dual Sense Trailing Edge Sensor Hytronik
File Info : application/pdf, 2 Pages, 1.33MB
DocumentDocumentTM Installation and Instruction Manual SURFACE MOUNT DUAL SENSE TRAILING EDGE SENSOR HIM16 1. Technical Specifications Product type Operating voltage Rated load Power consumption Detection angle Detection area (Max.)* Detection range Hold time Stand-by time Stand-by dimming level Daylight threshold Warmming up time Operating temperature Sensor mode Dual sense trailing edge motion sensor (HF and PIR, Daylight harvest) 120~277VAC 50/60Hz Resistive: 120W @ 120VAC; 200W @ 220~277VAC Trailing edge dimming driver: 100W @ 120V; 150W @ 220~277W < 1W 360o Installation Height : 6m Detection Range (Ø) :12m 10% / 50% / 75% / 100% 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min 0s / 10s / 1min / 5min / 10min / 30min / 1h / + 10% / 20% / 30% / 50% 50 ~ 500Lux, Disable 30s -20oC ~ +55oC PIR, HF, PIR+HF, PIR / HF 2. Installation 11 43.5 64.7 69.1 Warnings: 1. Installation must be carried out by a qualified engineer in accordance with local regulations. 2. Disconnect supply before installing. 3. Install to a solid surface - vibrations may cause mis-triggering. 4. Ensure environmental conditions are suitable for electronic equipment C - Surface box B - Facia Cover Infrared receiver HF Sensor module PIR Photocell LED indicator Blind A Blind Rotary switch preset Sensor mode selection B A - Control Board Note: the blinds are optional, they may be inserted behind the lens for focussing the detection range. 56 109 38.6 29 50.2 55.2 3. Rotary Switch Settings A rotary switch is built inside the sensor for scene selection / fast programming. Total 16 channels available: Rotary switch preset (Please see the location in 2. Installation) Channel Detection range Hold time Stand-by time Stand-by dimming level Daylight threshold 0 100% 5s 10s 10% 1 100% 1min 5min 10% 2 100% 5min 10min 10% 3 100% 5min + 10% 4 100% 5min + 10% 5 100% 5min + 30% 6 100% 10min 30min 10% 7 100% 10min + 10% 8 100% 10min + 10% 9 100% 10min + 30% A 100% 20min 1h 10% B 100% 20min + 30% C 100% 30min + 10% D 100% 30min + 30% E 100% 30min + 50% F 100% 5s 10s 10% Disable 50Lux 50Lux 75Lux 100Lux 200Lux 50Lux 75Lux 100Lux 200Lux 100Lux 200Lux 100Lux 200Lux 400Lux 100Lux Note: settings can also be changed by remote control HRC-11. The last action controls. 5. Functions 5.1 Daylight Harvest (Daylight Regulating) The built-in daylight sensor can measure ambient natural light, and calculate how much electrical light is needed to reach the target lux level. The target lux level can be adjusted by remote control or long press on the push switch. Light level Note:We recommend the mounting distance between sensor to sensor should be more than 2m to prevent sensors from false-triggering. Direct junction "J" box mounting a. Separate control board (A) from facia (B) & junction box (C). b. Make electrical connections to control board (A). See detailed wiring diagram on next page. c. Secure control board (A) to junction box. d. Set-up sensor modes as per sections 3 & 4 of this manual. e. Clip facial plate (B) to control board (A). Surface mount assembly a. Separate control board (A) from facia (B) & Surface box (C). b. Securely mount surface box (C) to a flat and solid surface. c. Make electrical connections to control board (A). See detailed wiring diagram on next page. d. Set-up sensor modes as per sections 3 & 4 of this manual. e. Secure control board (A) to surface box (C). f. Clip facial plate (B) to control board (A). C 56 A B C 56 A B Hold time Normal Electric Light Energy Saving Zone Stand-by time Daylight controlled light Natural light 0 5.2 Lux Off Function 24 Time (hrs) The light dims to minimum level even switches off completelly if ambient daylight is sufficient (natural light level exceeds target lux level), no matter it is during hold-time or stand-by time, with or without motion. Note: if the stand-by time is preset at "+", the light never turns off even when natural light is sufficient. 4. Sensor Mode Selection Sensor mode can be easily selected by choosing the correct combination of the DIP switches (see table below): 12 I HF II PIR III HF+PIR IV HF/PIR HF+PIR: Light is on when both HF and PIR sensors are activated. HF/PIR: Light is on when HF or PIR sensors are activated. HIM16-20190104-A1 5.3 Manual Override (Push Function) With the help of push-switch, this sensor maybe over-ridden by the end-users to switch on/off the lights manually, or adjust the target lux level. This makes the product more user-friendly and offers more options to fit for extra-ordinary demands. * Short push (<1s): on/off function; ON ¹ OFF: the light turns off immediately and cannot be lighten for a certain time (equals to hold time preset) even movement is detected. After this period, the sensor goes back to auto sensor mode. OFF ¹ ON: the light turns on and goes to auto sensor mode. * Long push (>1s): adjust the target lux level by turning the light up or down. Both the adjustment by remote control and push switch can overwrite each other, the last adjustment remains in memory. 5.4 Semi-auto Function (Absence Detection) The motion sensor is employed, but only activated on the manual press of the push switch. With presence, the light remains on and can interact with ambient natural light, then dims down in absence, eventually switching off automatically after the stand-by time has expired. Note: end-user can choose either function 5.3 or 5.4 for application. Default function is 5.3. 7. Detection Pattern 6. Wiring Diagram L N PUSH L' HIM16 N N L L N Trailing edge dimmable driver L N Trailing edge dimmable driver * Note: if neither function 5.3 nor 5.4 is desired, simply leave the "push" terminal disconnected. PIR HF 3m HFPIwR atalknignegnatiacrlomssov8emment 10m PIR A HF 3m PIR tangential movement 5m HF walking across 8m PIR B HF 3m 4m HF walking across 8m PIR tangential movement 10m 8. Description of the Permanent ON/OFF [button 1 ] Press button 1 to select permanent ON or permanent OFF mode. Daylight threshold [ zone 9 ] Press buttons in zone 9 to set the daylight sensor at 50Lux / 100Lux Button Functions (remote control HRC-11) * Press button 2 / 4 to resume automatic operation. The mode will change to AUTO Mode after power failure. RESET [ button 2 ] Press button 2 , all settings go back to the rotary switch settings. / 300Lux / 500Lux or Disable as threshold / target Lux level. Note: 2Lux / 10Lux are disabled. To set daylight sensor at 100Lux / 300 Lux / 500Lux, press button 3 Shift at first. Sensor mode return to DIP switch settings. Ambient daylight threshold [ button 10 ] Shift [ button 3 ] 4 Press button 3 , the LED on the top left corner flashes for indication. 1. Press button 3 Shift, the red LED flashes for indication. 2. Press button 10, the ambient lux level is sampled and set as daylight threshold / target Lux level. 1 2 All values / settings in RED are in valid for 20 seconds. 5 Auto Mode [ button 4 ] Press button 4 to initiate automatic mode. The sensor starts working Hold time [ zone 11 ] Press buttons in zone 11 to set the hold time at 2s / 30s / 1min / 3 and all settings remain as before the light was switched ON/OFF. 5min / 10min / 15min / 20min / 30min. Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press button 6 Semi-auto Mode [ button 3 & 4 ] 3 Shift at first. 7 1. Press button 3 Shift (the red LED flashes for indication), 2. press button 4 to initiate semi-auto mode. The fixture is manually on 2. 2s is for test purpose only, stand-by time and daylight sensor settings are disabled in this mode. by push-switch and automatically off in semi-auto mode. * To exit from Test mode, press button 2 or any button in zone 11 . 9 & A 4h h 4h HRC-11 8 Power output [ button 5 ] Press button 5 , the light output shifts between 80% and 100%. Note: the function of "Sensor off" and "Twilight" are disabled. 10 Brightness +/- [ button 6 ] Press button 6 to adjust light brightness to reset the target lux level. Stand-by time [ zone 12 ] Press buttons in zone 12 to set the stand-by time at 0s / 10s / 1min / 5min / 10min / 30min / 1h / +. Note: "0s" means on/off control; "+" means bi-level control, 100% on when motion detected, and remains at the stand-by dimming level when no presence after hold-time. 11 Scene prog. [ zone 7 ] (One-key-commissioning) 1. Press button "Start" to program. Stand-by dimming level [ zone 13 ] 2. Select the buttons in 8 "Detection range", 9 / 10 "Daylight threshold", Press buttons in zone 13 to set the stand-by dimming level at 10% / 12 11 "Hold time", 12 "Stand-by time", 13 "Stand-by dimming level" to 20% / 30% / 50%. set all parameters. 3. Press button "Memory" to save all the settings programmed in the Daylight harvest auto-configuration function 13 remote control. 4. Press button "Apply" to set the settings to each sensor unit(s). 1. Press button "Shift", the red LED is on for indication. 2. Select a time period and the sensor will do light level measurement For example, to pre-set detection range 100%, daylight threshold and determine/save the lowest light level (commission line) with 100% 14 Disable, hold time 5min, stand-by time +, stand-by dimming level 30%, steps should be: light on, so as to set the target lux level automatically. Note: 1. Make sure the light level measurement covers the night time. Press button 7 Start, button 8 100%, 10 Disable, 3 Shift, 11 5min, 2. The fixture will go into sensor mode after the measurement, 3 Shift, 12 + , 13 30%, 7 Memory. By pointing to the sensor unit(s) all sensor settings remain unchanged and pressing 7 Apply, all settings are passed on the sensor(s). Dual tech & RF mode [ zone 14 ] Detection range [ zone 8 ] Press buttons in zone 8 to set HF detection range at 100% / 75% / 50% / 10%. 1. Press buttons in zone 14 to select sensor technology. HF+PIR: Light is on when both HF and PIR sensors are activated. HF/PIR: Light is on when HF or PIR sensors are activated. 2. Learn / Erase, Transmit, RX100% and RX STBY% are disabled. Hytronik Industrial Ltd. | www.hytronik.com 3rd Floor, block C, complex building, 155#, Bai'gang road south, Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023 Tel: 86-752-2772020 Fax: 86-752-2777877 HIM16-20190104-A1