Kaisai KCD Series Cassette Air Conditioners
The Kaisai KCD series offers cassette air conditioning units, perfectly suited for spaces with suspended ceilings and compact technical rooms.
Key Features
The air intake slots have been enlarged by 23%, resulting in quieter operation and improved efficiency. The condensate pump's lifting height has been increased to 100 cm, and its external placement simplifies maintenance and replacement. A new integrated WiFi connection allows for control via a smartphone or tablet app.
Kaisai KCD Functions
Jalousie-Luftauslassspeicher: Storage for fresh louver settings.
360° Luftzufuhr: 360° air supply.
Anzeige von Kältemittelleckagen: Refrigerant leak detection indicator.
Betrieb bei niedrigen Außentemperaturen: Operation at low outdoor temperatures.
Temperaturfühler der Fernbedienung: Remote control temperature sensor.
Notfallbeheizung: Emergency heating function.
Timer: Timer function.
Automatischer Neustart: Automatic restart.
Alarm-schluss: Alarm shut-off.
Autodiagnose: Self-diagnosis.
Schlaffunktion: Sleep mode.
Twin-Kombinations Modus: Twin combination mode.
Turbo Modus: Turbo mode.
Gear-Modus: Gear mode.
Öko-Modus: Eco mode.
Eingebaute Kondensatpumpe: Built-in condensate pump.
Leiser Betrieb: Quiet operation.
Temperaturkompensation: Temperature compensation.
Kompressor- Ein-/Ausschluss: Compressor on/off.
Kondensat- und Kondensationsheizung: Condensate and condensation heating.
Selbstleinigender Verdampfer: Self-cleaning evaporator.
Stufenlose Lüftersteuerung: Stepless fan speed control.
Kaltluft-Steuerung: Cold air control.
Funktion Heizung 8°C: 8°C heating function.
Wi-Fi Steuerung: Wi-Fi control.
Funktion Vane: Vane function.
Breeze Away Funktion: Breeze Away function.
Zentrales Steuergerät: Central control unit.
Kabelgebundenes Steuergerät: Wired control unit.
Technische Spezifikation
MODELL | Innengerät | KCD-34HRG32X | KCD-36HRG32X | KCD-36HRG32X | KCD-45HRG32X | KCD-55HRG32X | |
Außengerät | KOX430-24HF-N32X | KOD30U-36HFJ32X | KOD30U-36HF-N32X | KDE30U-45HF-N32X | KDE30U-55HF-N32X | ||
Leistung Mittelwert (min+max) | Kühlung | kW | 7,0(3,3+7,9) | 10,6(2,7+11,4) | 10,6(2,7+11,4) | 14,1(3,5+15,8) | 15,2(4,1+16,7) |
Heizen | kW | 7,6(2,8+8,9) | 11,1(2,8+12,0) | 11,1(2,8+12,7) | 16,1(4,1+17,3) | 18,2(4,4+19,9) | |
Energieeffizienzklasse | Kühlung/ Heizung | A++/ A+ | A++/ A+ | A++/ A+ | A++/ A+ | A++/ A+ | |
SEER | mittel | W/W | 6,2 | 6,7 | 6,4 | 6,1 | 6,3 |
SCOP | mittel | W/W | 4,0 | 4,0 | 4,0 | 4,0 | 4,0 |
Stromaufnahme Mittelwert (min+max) | Kühlung | W | 2320 (780+2748) | 3950 (900+4200) | 4000 (890+4150) | 4650 (800+5900) | 5000 (980+6200) |
Heizen | W | 1900 (610+2700) | 3000 (800+3950) | 3000 (780+4000) | 4580 (900+5500) | 5550 (1020+6700) | |
Betriebsstrom Mittelwert (min+max) | Kühlung | A | 10,2(4,2+12,0) | 17,5 (4,2+18,5) | 6,5 (1,4+6,5) | 8,1 (1,8+10,2) | 8,6 (2,1+10,7) |
Heizen | A | 8,5 (3,6+12,1) | 13,5 (3,5+17,5) | 5,0 (1,3+6,4) | 8,0 (1,9+9,5) | 9,6 (2,1+10,7) | |
Luftdurchfluss | innen | m³/h | 1300/1140/1000 | 1700/1550/1380 | 1800/1600/1400 | 1970/1780/1580 | 2000/1850/1650 |
außen | m³/h | 3500 | 4000 | 4000 | 7500 | 7500 | |
Betriebstemperatur Kühlung/Heizung | innen | °C | 16+32 / 0+30 | 16+32 / 0+30 | 16+32 / 0+30 | 16+32 / 0+30 | 16+32 / 0+30 |
außen | °C | -15+50 /-15+24 | -15+50 /-15+24 | -15+50 /-15+24 | -15+50 /-15+24 | -15+50 /-15+24 | |
Schalldruckpegel | innen | dB(A) | 45,5/42,5/39,5/27 | 50/47,5/44,5/39 | 50/47,5/44,5/39 | 51/48,5/46,5/37,5 | 53/50,5/48/40 |
außen | dB(A) | 60 | 63 | 63 | 63,5 | 64 | |
Nettoabmessungen B/H/T | innen | mm | 830/205/830 | 830/245/830 | 830/245/830 | 830/287/830 | 830/287/830 |
panel | mm | 950/55/950 | 950/55/950 | 950/55/950 | 950/55/950 | 950/55/950 | |
außen | mm | 890/673/342 | 946/810/410 | 946/810/410 | 952/1333/415 | 952/1333/415 | |
Transportabmessungen B/H/T | innen | mm | 910/250/910 | 910/290/910 | 910/290/910 | 910/330/910 | 910/330/910 |
panel | mm | 1035/90/1035 | 1035/90/1035 | 1035/90/1035 | 1035/90/1035 | 1035/90/1035 | |
außen | mm | 995/740/398 | 1090/885/500 | 1090/885/500 | 1095/1480/495 | 1095/1480/495 | |
Netto Gewicht | innen | kg | 21,6/6,0 | 27,2/6,0 | 27,2/6,0 | 29,3/6,0 | 29,3 /6,0 |
außen | kg | 43,9 | 66,9 | 80,5 | 103,7 | 107,0 | |
Transportwaage | innen | kg | 25,4/9,0 | 31,2/9,0 | 31,2/9,0 | 33,5/9,0 | 33,5/9,0 |
außen | kg | 46,9 | 71,5 | 85,0 | 118,3 | 121,2 | |
Rohrdurchmesser Flüssigkeit/Gas | mm | 9,52/15,9 | 9,52/15,9 | 9,52/15,9 | 9,52/15,9 | 9,52/15,9 | |
Max. Anlagenlänge | m | 50 | 75 | 75 | 75 | 75 | |
Max. Pegelunterschied | m | 25 | 30 | 30 | 30 | 30 | |
Stromversorgung | zewn. | V /mz / Ph | 220+240/50/1 | 220+240/50/1 | 380+420/50/3 | 380+420/50/3 | 380+420/50/3 |
Sicherung | zewn. | A | 20 | 25 | 16 | 16 | 16 |
Versorgungsleitungen | zewn. | Anzahl von Leitern × mm² | 3 × 2,5 | 3 × 4,0 | 5 × 2,5 | 5 × 2,5 | 5 × 2,5 |
Steuerleitungen | innen - außer | Anzahl von Leitern × mm² | 4 × 1,5 | 4 × 1,5 | 4 × 1,5 | 4 × 1,5 | 4 × 1,5 |
Ab Werk Kältemittelfüllung | bis zu 5 lfm | kg | 1,5 | 2,4 | 2,4 | 2,9 | 3,0 |
Zusätzliche Kältemittelfüllung | über 5 lfm | g / m | 24 | 24 | 24 | 24 | 24 |
Außendurchmesser Kondensatabfluss | mm | 25 | 25 | 25 | 25 | 25 |
Steuergeräte
KABELLOSE FERNsteuerung: RG10N2
KABELGEBUNDENE FERNBEDIENUNG: KJR-120X2 (OPCJA)
KABELGEBUNDENE FERNBEDIENUNG: CCM (OPCJA)