Instruction Manual for MEAN WELL models including: GST90A12-P1M, GST90A15-P1M, GST90A19-P1M, GST90A24-P1M, GST90A48-P1M, GST90A Series 90W AC-DC Reliable Green Industrial Adaptor, GST90A Series, 90W AC-DC Reliable Green Industrial Adaptor, Reliable Green Industrial Adaptor, Green Industrial Adaptor, Industrial Adaptor
GST90A24-P1M MEAN WELL - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 5 Pages, 957.42KB
DocumentDocument90W AC-DC Reliable Green Industrial Adaptor GST90A series User's Manual Video UL62368-1 Bauar t gepruft Sicherheit egelma ge od o s be wac g www.tuv.com ID 2000000000 BS EN/EN62368-1 R33100 RoHS J62368-1 THOMAS SAMUEL THOMAS SAMUEL K60950-1 AS/NZS60950-1 GB4943.1 IS13252 IEC62368-1 TPTC004 https://www.meanwell.com/serviceGTIN.aspx https://www.meanwell.com/upload/pdf/DC_plug.pdf Downloaded from Arrow.com. { File Name:GST90A-SPEC 2024-10-30 90W AC-DC Reliable Green Industrial Adaptor GST90A series SPECIFICATION ORDER NO. GST90A12-P1M GST90A15-P1M GST90A19-P1M GST90A24-P1M GST90A48-P1M SAFETY MODEL NO. GST90A12 GST90A15 GST90A19 GST90A24 GST90A48 DC VOLTAGE Note.2 12V 15V RATED CURRENT 6.67A 6A 19V 4.74A 24V 3.75A 48V 1.87A CURRENT RANGE 0 ~ 6.67A 0 ~ 6A 0 ~ 4.74A 0 ~ 3.75A 0 ~ 1.87A OUTPUT INPUT RATED POWER (max.) 80W 90W 90W RIPPLE & NOISE (max.) Note.3 120mVp-p 150mVp-p 180mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±4.0% LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% LOAD REGULATION ±5.0% ±5.0% ±4.0% SETUP, RISE TIME Note.6 1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load HOLD UP TIME (Typ.) 20ms / 230VAC 20ms / 115VAC at full load VOLTAGE RANGE Note.7 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.91 / 230VAC PF>0.95 / 115VAC at full load EFFICIENCY (Typ.) 89% 89.5% 90% AC CURRENT (Typ.) 1.3A / 115VAC 0.6A / 230VAC INRUSH CURRENT (max.) Cold start 35 / 115AC 70A / 230VAC LEAKAGE CURRENT(max.) 1mA / 240VAC 90W 200mVp-p ±3.0% ±1.0% ±3.0% 90% 90W 200mVp-p ±2.5% ±1.0% ±2.5% 91% OVERLOAD PROTECTION OVER VOLTAGE 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. -30 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT ±0.03% / (0~40) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS Note. 8 UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, CCC GB4943.1, PSE J62368-1,AS/NZS 60950.1 , BIS IS13252, KC K60950-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted emission BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS15936,GB17625.1 Class B EAC TP TC 020,MSIP KN32 EMC EMISSION SAFETY & EMC (Note. 10) Radiated emission Harmonic current Voltage flicker BS EN/EN55035 Parameter BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS15936,GB17625.1 EAC TP TC 020,MSIP KN32 Class B BS EN/EN61000-3-2,GB9254 Class A BS EN/EN61000-3-3 ------- Standard Test Level /Note ESD BS EN/EN61000-4-2 Level 4, 15KV air; Level 4, 8KV contact RF field susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EMC IMMUNITY EFT bursts Surge susceptibility BS EN/EN61000-4-4 BS EN/EN61000-4-5 Level 2, 1KV Level 3, 1KV/Line-Line , 2KV/Line-FG Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V Magnetic field immunity Voltage dips , interruption BS EN/EN61000-4-8 BS EN/EN61000-4-11 Level 2, 3A/m 95% dip 0.5 periods, 30% dip 25 periods, 95% interruptions 250 periods MTBF 2529.4K hrs min. Telcordia SR-332 (Bellcore) ; 389.3K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 145*60*32mm (L*W*H) PACKING 0.45Kg; 30pcs/14.05Kg/0.9CUFT PLUG CONNECTOR CABLE See page 4~5 ; Other type available by customer requested See page 4~5 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1F & 47F capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. NOTE 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltages. Pleas check the derating curve for more details. 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:GST90A-SPEC 2024-10-30 LOAD (%) 60 LOAD (%) 90W AC-DC Reliable Green Industrial Adaptor GST90A series Derating Curve Static Characteristics 100 80 60 50 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 100 90 80 70 60 50 40 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Mechanical Specification (Unit: mm , tolerance ± 1mm) Case No. GS90A 32 145 Ul1185 14AWG 1000±50mm for 12 ~ 15V UL1185 16AWG 1200±50mm for 19 ~ 48V 70±10mm AC Inlet IEC320-C14 Power LED DC output plug Standard plug: P1M P1M 5.5 2.5 11±0.5mm Pin Assignment C"+" Outside Inside -V not connected to AC FG Downloaded from Arrow.com. File Name:GST90A-SPEC 2024-10-30 90W AC-DC Reliable Green Industrial Adaptor GST90A series DC plug changeable through: (1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable) (2) Quick adapter accessory (sold separately without MOQ) Please refer to below table and online selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf Example quick adapter accessory: Optional DC plug: (Available in customized cable or quick adapter) Tuning Fork Style Type No. A B Barrel Style C (Straight) C (Right-angled) P1I P1L P1J P1JR P1IR P1LR P1MR Type No. C P2I P2J P2L A (Straight) P2M B C P2IR P2JR (Right-angled) P2LR P2MR Lock Style Type No. A Floating Locking C P2S(S761K) P2K(761K) B P2C(S760K) SWITCHCRAFT original or equivalent P2D(760K) Min. Pin Style Type No. A C P3A B EIAJ equivalent P3B P3C Center Pin Style Type No. A C P4A B P4B D EIAJ equivalent P4C A OD 5.5 5.5 5.5 5.5 5.5 5.5 5.5 A OD 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 A OD 5.53 5.53 5.53 5.53 A OD 2.35 4.0 4.75 A OD 5.5 6.5 7.4 B ID 2.1 2.5 2.1 2.1 2.1 2.5 2.5 B ID 2.1 2.1 2.5 2.5 2.1 2.1 2.5 2.5 B ID 2.03 2.54 2.03 2.54 B ID 0.7 1.7 1.7 BC ID L 3.4 11.0 4.4 11.0 5.1 11.0 C L 9.5 9.5 11.0 11.0 9.5 9.5 11.0 C L 9.5 11.0 9.5 11.0 9.5 11.0 9.5 11.0 C L 12.06 12.06 9.52 9.52 C L 11.0 11.0 Quick Adapter Accessory Available (Current rating: 7.5A max.) None None None 11.0 D Center Pin 1.0 None 1.4 0.6 Downloaded from Arrow.com. File Name:GST90A-SPEC 2024-10-30 90W AC-DC Reliable Green Industrial Adaptor GST90A series Min. DIN 3 Pin with Lock (male) 1 3 2 KYCON KPPX-3P equivalent Min. DIN 4 Pin with Lock (male) 23 14 KYCON KPPX-4P equivalent Min. DIN 4 Pin with Lock (female) 23 14 KYCON KPJX-CM-4S equivalent DIN 5 Pin (male) 13 425 Stripped and tinned leads Type No. R6B Type No. R7B Type No. R7BF Type No. R1B Type No. Pin Assignment PIN No. Output 1 +Vo 2 -Vo 3 +Vo Pin Assignment PIN No. Output 1 +Vo 2 -Vo 3 -Vo 4 +Vo Pin Assignment PIN No. Output 1 +Vo 2 -Vo 3 -Vo 4 +Vo Pin Assignment PIN No. Output 1 -Vo 2 -Vo 3 +Vo 4 -Vo 5 +Vo Pin Assignment PIN No. Output L (red) 1 2 1 +Vo L1 (black) by customer Length of Land L1 by request (MW's standard length, L: 25 mm, L1: 5 mm) ( NOTE: The wire color is for reference only, please refer to the actual product) 2 -Vo Quick Adapter Accessory None Available (Current rating: 7.5A max.) None None None Installation Manual Please refer to : http://www.meanwell.com/manual.html Downloaded from Arrow.com. File Name:GST90A-SPEC 2024-10-30