General Specifications
Total Flux | 13888 lm (@zoom 128, integrating sphere measurement, Fan mode auto) |
CCT @LED engin | 7000 (±500K) |
CCT @open | 6500 (±500K) |
Ra @open | 90 (±2) |
TLCI | 90 |
TM-30 | Rf: 87,1 Rg: 93,8 |
Fan Mode Noise Levels
Fan Mode | Noise Level (dBA) | by Goniometer (lm) | by Sphere (lm) |
---|---|---|---|
Auto | 44,9 | 11203 | 13586 |
Stage | 47,3 | 11197 | 13888 |
Silence | 39,6 | 7275 | 11783 |
Super Silence | 34,7 | 6681 | 8227 |
Note: noise measured @1m distance, static status, ambient 31 dBA.
Voltage / Power | 100-240 V, 50-60 Hz | 550 W |
Fixture Dimension / Weight | 365 x 591 x 208 mm | 22 kg |
Packing Dimension / Weight | 445 x 750 x 295 mm | 30,5 kg |
Photometric Data - Auto Mode
Min Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 24854 | 0,61 | 6213 | 1,22 | 2762 | 1,83 | 1553 | 2,45 |
Middle Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 5202 | 1,85 | 1300 | 3,71 | 578 | 5,56 | 325 | 7,41 |
Max Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 940 | 4,99 | 235 | 9,97 | 104 | 14,96 | 59 | 19,94 |
Photometric Data - Stage Mode
Min Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 25441 | 0,61 | 6360 | 1,22 | 2827 | 1,83 | 1590 | 2,45 |
Middle Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 5247 | 1,85 | 1312 | 3,71 | 583 | 5,56 | 328 | 7,41 |
Max Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 953 | 4,99 | 238 | 9,97 | 106 | 14,96 | 60 | 19,94 |
Photometric Data - Silence Mode
Min Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 16037 | 0,61 | 4009 | 1,22 | 1782 | 1,83 | 1002 | 2,45 |
Middle Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 3377 | 1,85 | 844 | 3,71 | 375 | 5,56 | 211 | 7,41 |
Max Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 607 | 4,99 | 152 | 9,97 | 67 | 14,96 | 52 | 19,94 |
Photometric Data - Super Silence Mode
Min Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 14689 | 0,61 | 3672 | 1,22 | 1632 | 1,83 | 918 | 2,45 |
Middle Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 3072 | 1,85 | 768 | 3,71 | 341 | 5,56 | 192 | 7,41 |
Max Zoom
This diagram illustrates the beam opening and intensity distribution. The Y-axis represents beam opening in centimeters (cm), and the X-axis represents distance in meters (m). A shaded area indicates the beam spread. Below the diagram, a table shows the intensity in Lux and the beam diameter in meters at various distances (5m, 10m, 15m, 20m).
Distance (m) | 5 | 10 | 15 | 20 | |||||
---|---|---|---|---|---|---|---|---|---|
unit | Lux | Diameter | Lux | Diameter | Lux | Diameter | Lux | Diameter | |
White | 555 | 4,99 | 139 | 9,97 | 62 | 14,96 | 35 | 19,94 |
Color Details
The CIE 1931 chromaticity diagram shows the color space with the product's color coordinates at x: 0.308, y: 0.332. The diagram plots the Planckian locus for color temperatures, indicating the product's color point is approximately 6739 K with a Delta uv of 0.0039.
Color rendering data includes TM-30 values (Rf: 87.1, Rg: 93.8) presented with bar charts showing fidelity (Rf) and gamut (Rg) across 16 hue bins. CRI (Color Rendering Index) is 89.6 (R1-R8), also shown with bar charts for R1-R15 values. CQS (Color Quality Scale) is 88.2, displayed with a bar chart for Q1-Q15 values.
Color temperature | Color rendering index | Red component | Color fidelity | Color gamut | Color quality scale | Color coordinate cie 1931 (x) | Color coordinate cie 1931 (y) | Color coordinate (u) | Color coordinate (v) | Color deviation from black body |
---|---|---|---|---|---|---|---|---|---|---|
6739 K | 89.6 | 45.0 | 87.1 | 93.8 | 88.2 | 0.308 | 0.332 | 0.193 | 0.313 | 0.0039 |
TM-30 Details
The TM-30 analysis provides a detailed breakdown of color rendering. The Fidelity Index (Rf) is 87.1, and the Gamut Index (Rg) is 93.8. Bar charts illustrate the Rf values by hue and the chroma shift by hue across 16 hue bins, showing how color saturation and accuracy vary with different colors.
Additional graphics include 'Color vector graphics' and 'Color distortion graphics', which visually represent the light source's color rendering performance and potential color shifts. A 'Color Evaluation Sample' chart further details the performance across various color samples.
TLCI Data
The fixture's Television Lighting Consistency Index (TLCI) is rated at 90. The following table details the measured TLCI values for various color samples:
Color Sample | TLCI Value |
---|---|
Dark skin | - |
Light skin | - |
Blue sky | - |
Foliage | - |
Blue flower | - |
Bluis green | - |
Orange | - |
Purplish blue | - |
Moderate red | - |
Purple | - |
Yellow green | - |
Orange yellow | - |
Blue | - |
Green | - |
Red | - |
Yellow | - |
Magenta | - |
Cyan | - |
White | 90.01% |
Neutral 8 | 59.1% |
Neutral 6.5 | 36.2% |
Neutral 5 | 19.77% |
Neutral 3.5 | 9% |
Black | 3.13% |