WARNING: SHOCK HAZARD
This device is intended for installation in accordance with the National Electric Code and local regulations in the United States and the Canadian Electrical Code and local regulations in Canada. For installation, consult a qualified electrician if unsure or uncomfortable.
PoE Keypad Wiring
The PoE 6-Button Keypad connects via a single Ethernet cable, receiving both data and power from a PoE-compliant switch or a separate PoE injector. Standard CAT5e cables are supported.
Installation Steps:
- Remove the wall plate.
- Remove switch mounting screws.
- Carefully detach the switch from the switch box.
- Locate the single RJ45 port on the back of the keypad.
IMPORTANT: Ensure the Power over Ethernet (PoE) source is rated for 30W at 48V DC.
LED Indicators
Upon correct power-up via PoE, all LEDs will illuminate, signaling the device is ready for provisioning.
Legal and Compliance Information
Specifications: Input: 37-57VDC (nominal 48VDC). Operating Ambient Temperature: 0-40°C. For indoor use only.
FCC Compliance
Supplier's Declaration of Conformity, 47 CFR 2.1077. Model: QK6POE-01. Responsible Party: SAVI Controls, 2520 Marsh Lane, Carrollton, TX 75006-2401, (214) 785-6510.
This device complies with FCC Part 15 rules. Operation is subject to two conditions: it must not cause harmful interference, and it must accept any interference received, including that which may cause undesired operation.
SAVI Controls is not liable for interference caused by unauthorized modifications. Visit savicontrols.com for full FCC/IC statements.
This equipment meets FCC radiation exposure limits for uncontrolled environments and requires installation with a minimum 20cm separation from the body.
IC Compliance (Canada)
This device complies with FCC Part 15 and Industry Canada's RSS. Operation is subject to two conditions: no harmful interference, and acceptance of any received interference.
This equipment meets ISED RSS-102 radiation exposure limits for uncontrolled environments and requires installation with a minimum 20cm separation from the body.
French Compliance: Le présent appareil est conforme aux CNR d'Industrie Canada. L'exploitation est autorisée sous deux conditions: 1. L'appareil ne doit pas produire de brouillage. 2. L'utilisateur doit accepter tout brouillage radioélectrique subi. 3. Une distance de séparation d'au moins 20 cm doit être maintenue entre l'antenne et les personnes.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.