Owner's Manual for Raypak models including: B-R206A Digital Asme Propane Gas Commercial Swimming Pool Heater, B-R206A, Digital Asme Propane Gas Commercial Swimming Pool Heater, Propane Gas Commercial Swimming Pool Heater, Gas Commercial Swimming Pool Heater, Swimming Pool Heater
Raypak Digital ASME Propane Gas Commercial Swimming Pool Heater | 266k BTU Cupro Nickel Heat Exchanger | Altitude 2000-2999 Ft | B-R266A-EP-X #58 017416 | Pool Supply Unlimited
File Info : application/pdf, 3 Pages, 831.62KB
DocumentDocumentJob: Engineer: Contractor: Prepared by: Date: Model: Features: · 82% Efficiency · ASME Code Bronze Headers · ASME Code Copper-Fin Tube · 75 lb. Pressure Relief Valve · Small Footprint · Unitherm Governor Anti-Condensation Control · Indoor/Outdoor · Proudly Assembled in the USA Product Submittal for ASME Digital/Millivolt Atmospheric Gas Pool Heaters Models B-R206A B-R406A Indoor/Outdoor Digital model with outdoor top shown Part No.: 241897 Rev. 1 Effective: 09-01-20 Replaces 6000.38F Page 1 of 3 Product Submittal for ASME Digital/Millivolt Atmospheric Model Heat exchanger Q ASME HLW stamped; 100 PSIG MAWP Q National board registered Q Bronze headers Q Finned tubing Copper (standard) Cupronickel (optional, digital units only) Q ASME Steel tube sheet Q Silicone O-rings Q Fixed high limit, auto reset, 160°F Q Fixed high limit, manual reset, 135°F Q 75 PSIG Pressure relief valve Q Water connections Right hand (standard) Left hand (optional-field change) Q Flow configuration (two-pass) Controls Millivolt option Q Standing pilot ignition Q Thermopile generator Q Single mechanical temperature control Q Flame rollout switch Q High limit control Q On/off switch Q Water pressure switch Digital option Q 120/240V, 60Hz, 1 Ph power supply Q 120/240/24V Transformer Q 100% Pilot shut-off; lockout (propane only) Q Electronic, intermittent ignition pilot (IID) Q High limit control Q On/off switch Q Flame rollout switch Q Water pressure switch Q Dual electronic temp sensor Q Digital display with diagnostics Gas control train Q Fuel Natural gas Propane (minimum grade HD-5) Q Combination control valve Q On/off firing Construction Q Front controls Q ANSI Z21.56 design certified Q Stainless steel burners Q Polytuf powder coat finish Q Indoor/outdoor Q Can be installed on combustible surface Q Venting Outdoor stackless top (included) D-2 Power vent indoor, loose (optional for digital models, see 1000.70) D-10 Indoor draft diverter, loose (optional) D-13 High wind top (optional, outdoor) Outdoor high wind stack (optional) Other options PoolStat cover/lock kit X-10 Restraint bracket (Florida code requirement) Part No.: 241897 Rev. 1 Effective: 09-01-20 Replaces 6000.38F Page 2 of 3 Product Submittal for ASME Digital/Millivolt Atmospheric Model Heater Model B-R206A B-R266A B-R336A B-R406A MBTUH (kWh) Input 199.5 (58.47) 266.0 (77.96) 332.5 (97.45) 399.0 (117) Cabinet Width (A) 20 (508) 23 (584) 26 (660) 29 (736) Dimensions in. (mm) Flue Dia. (B) 6 (152) 7 (178) 8 (203) 9 (229) Indoor Drafthood (C) 61.63 (1565) 62 (1575) 63 (1600) 64.5 (1638) Shipping Weights lbs. (kg) Draft Relief Height (J) Heater with Stackless Top 11.75 (298) 212 (96.16) 11 (279) 235 (106.59) 10.63 (270) 250 (113.39) 12.13 (308) 269 (122) Indoor Drafthood 14 (6.35) 16 (7.26) 19 (8.62) 21 (9.52) Notes: 1. Model number suffix indicates pilot type (E = digital, M = millivolt), fuel type (P = propane, N = natural gas) and tube material (C = copper, X = cupronickel). Example: Model number B-R406A-EN-C indicates a unit with digital (IID) ignition using natural gas with copper tubes. 2. Ratings are for natural gas and elevations up to 2,000 feet above sea level. Reduce input 4% for each 1,000 feet above sea level when installed at over 2,000 feet elevation. Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 www.raypak.com Part No.: 241897 Rev. 1 Effective: 09-01-20 Replaces 6000.38F Page 3 of 3