KY-48P-0324-1

4. WARNINGS

E-48P Series

Universal Advanced

Digital Controllers

R1

Quick Start Guide

R2

Manufacturer / Technical Support
Elimko Elektronik malat ve Kontrol Ltd. ti. 8. Cadde 21. Sokak No:16 Emek 06510 Ankara / TÜRKYE Telefon: + 90 312 212 64 50 Faks: + 90 312 212 41 43
48P www.elimko.com.tr · e-mail:elimko@elimko.com.tr

1. DESCRIPTION
E-48P Series universal process controllers are industrial devices at 48x48 mm IEC/TR 60668 dimensions designed using new generation microcontrollers with on/off, PID and other control forms, where inputs and outputs can be easily programmed by the user.
In E-48P Series controllers, the set value and measured value can be displayed from -1999 to 9999 on two 4-digit displays; general purpose inputs (T/C, R/T, mV, mA) can be programmed.

2. DIMENSIONS and PANEL CUT-OUT

48 mm

R1 R2
48P

K on trol Edilmitir
2

TP

: E48

SKALA :

GR :

ÇIKI :

SER NO : 21/14798

Tel: +90 3122126450 Fax: +90 3122124143
TÜ RKYE

44 mm

-0.0 45 x 45 mm
+0.5
10 mm min.

35 mm min.

Panel Cut-Out and Minimum Spacing

3. CONNECTION DIAGRAM

RL1 13 RL2 14

01

06

SSR2

02 SSR1

07

03

08

Operating voltage suitable for the device type shall be applied.

RL3

04

09

AO1

05

11

12 10

RS 485

1st and 2nd control outputs can be selected as either Relay (RL1, RL2) or SSR (SSR1, SSR2).
Only one of analog output (AO1) and RS-485 can be selected.
Analog output (AO1) mA or 0-10 V DC can be selected.

Analog Input

06

06

07

07

08

08

09

09

10

10

06

06

07

07

08

08

09

09

10

10

06

07

08

09

V

10

E-48P controller is designed for panel mounting and should be used in an industrial environment.
 The package of E-48P controller conta ns; Controller, 2 p eces of mount ng clamps, User manual and Guarantee cert f cate.
 After open ng the package, please check the contents w th the above l st. If the del vered product s wrong type, any tem s m ss ng or there are v s ble defects, contact the vendor from wh ch you purchased the product.
 Before nstall ng and operat ng the controller, please read the user manual thoroughly.
 The nstallat on and conf gurat on of the controller must only be performed by a person qual f ed n nstrumentat on.
 Keep the un t away from flamable gases, that could cause explos on.
 Do not use alcohol or other solvents to clean the controller. Use a clean cloth soaked n water t ghtly squeezed to gently w pe the outer surface of the controller.
 It s not used n med cal appl cat ons.

EU DIRECTIVE COMPLIANCE
Low Voltage D rect ve EN 61010-1 EMC D rect ve EN 61326-1

K - Q TSE-ISO-EN
9000
TS EN ISO 9001 Quality Management System Certificate

5. TYPE CODING
E-48 Series Universal Advanced Controller

E-48 - W - X - Y - Z

Relay Outputs

None

0

1 relay (RL1)

1

2 relays (RL1, RL2)

2

3 relays (RL1, RL2, RL3)

3

1 SSR (SSR1)

4

1 SSR (SSR1) + 1 relay (RL2)

5

1 SSR (SSR1) + 2 relay (RL2, RL3)

6

2 SSR (SSR1, SSR2)

7

2 SSR (SSR1, SSR2) + 1 relay (RL3)

8

Analog Outputs *

None

0

0-20 / 4-20 mA (AO1)

1

0-10 V DC (AO1)

2

Communication

None

0

RS-485 **

1

Operating Voltage

85-265 V AC / 85-375 V DC

0

20-60 V AC / 20-60 V DC

1

* Only one of the relay 3 output, Analogue output and RS485 Modbus options can be coded. For example, only one of the (X) and (Y) options can be coded as 1. Similarly, when the (W) option includes Relay 3 (W=3, 6 or 8) X and Y 1 cannot be selected.
** When E-48 Series controllers are ordered with communication, the E-IB-11 USB-RS485 converter can be used for PC connection. There are various control and monitoring software provided by Elimko.

6. TECHNICAL SPECIFICATIONS

Parameter

Description

Control Type

On/Off, PID, Heat/Cool, Floating and Feedback Control of Valves

Operating Voltage

20..60 V AC / 20..60 V DC or 85..265 V AC / 85..375 V DC

Relays / SSR

2 pieces SPST - NO 250 V AC 5A relays or 24 V DC 25 mA (SSR) drives

Dimensions (mm)

48 (Lenght) x 48 (Height) x 100 (Width)

Panel Cut-Out (mm)

45 (Lenght) x 45 (Height)

Analog Output

1 x 0..20 / 4..20 mA or 0..10 V DC optional

Analog Input

Universal (Note 1),

Communication (RS-485) Available (RS-485)

Digital Input

None

Valve Feedback

None

Transmitter Supply

Available

Weight

115 g

Power Consumption Max. 7 W (10 VA)

Operating Temperature - 10 °C ... 55 °C

Storage Temperature - 25 °C ... 65 °C

Memory

Maks. 100.000 write

Protection Class

IP-65 Front Panel, IP-20 Rear Case

Notes:

(1) Universal Input :

Thermocouple

: B, E, J, K, L, N, R, S, T, U

Resistance Thermometer : Pt-100

Current

: 0-20 mA, 4-20 mA (Linear)

Voltage

: 0-50 mV, 0-1 V, 0.2- 1 V (Linear),

0-10 V DC, must be specified in the order.

Resolution

: 16 bit

Accuracy

: Thermocouple, Max. ±1.0 °C (Conversion and CJC error)

Resistance Thermometer, Max. ±0.5 °C

(Conversion and wire resistance compensation)

Linear Input, Max. % 0.1

7. PARAMETER TABLE

Description

Analog Input 1 Type

Decimal Point

Analog Input 1 Linear Scale Lower Value

Analog Input 1 Linear Scale Upper Value

Temperature Unit

Analog Input 1 Offset Value

Analog Input 1 Filter

Analog Input 1 Sensor Broken Behaviour

Modbus Adress

Modbus Baud Rate [

kbaud]

Modbus Parity [

]

Min Maks Unit

Table 1

0

3

-199.9 999.9 EU

-199.9 999.9 EU

-100.0 100.0 EU 1 15 s

1 127

Control Set Point Source Control Set Point Lower Limit Control Set Point Upper Limit Control Set Point Ramping Rate 1. Step Set Value 1. Step Time 2. Step Set Value 2. Step Time 3. Step Set Value 3. Step Time

Table 2

-199.9

EU

999.9 EU

60.0 EU/min

EU

999.9 min

EU

999.9 min

EU

999.9 min

Alarm 1 Type Alarm 1 Set Point Alarm 1 Hysteresis Alarm 1 Lock Alarm 2 Type Alarm 2 Set Point Alarm 2 Hysteresis Alarm 2 Lock Alarm 3 Type Alarm 3 Set Po nt Alarm 3 Hysteres s Alarm 3 Lock

Control Type

Control Form [

]

Control Period

Manual Mode Selection

Floating Control Valve Travel Time

Dead Band

Control Output Lower Limit

Control Output Upper Limit

Control Output Manual Reset

PID Power On Behaviour

Retransmission Scale Lower Value

Retransmission Scale Upper Value

Relay 1 Function

Relay 2 Function

Relay 3 Funct on

Analog Output 1 Function

Analog Output 1 Type

PID Auto Tune PID Parameter Type Proportional Band + Proportional Band Integral Time + Integral Time Derivative Time + Derivative Time Hysteresis

Table 3 -199.9 999.9 EU
0.0 999.9 EU
Table 3 -199.9 999.9 EU
0.0 999.9 EU
Table 3 -199.9 999.9 EU
0.0 999.9 EU

Table 4

1 250 s

10 2500 s

0.1 25.0 %

0.0

%

100.0 %

%

0

4

-199.9

EU

999.9 EU

Table 5

Table 5

Table 5

Table 6

Table 7.1 ve Table 7.2

0.1 999.9 EU 0.1 999.9 EU
9999 s 9999 s 2500 s 2500 s 0.0 999.9 EU

Security Code

Parameter Access Level

Parameter Setting Level

Factory Settings [

]

0 9999

0

9

0

9

8. ACCESSING PARAMETERS

STEP 1:

STEP 2:

Security Code Configuration

Entry Page Selection

(Default: 10) and Entry

STEP 3: Parameter Selection and Configuration

Process Screen

 

 

Selected Page
  Parameters . . .







Adjustment

Enter

Return

Menu Access


9. APPLICATION EXAMPLES
1) Input: Pt-100 Relay / Alarm1: 50 °C Low, Relay2 / Alarm2: 55 °C High AO1: 4-20 mA PID Control Output
2) Input: TC Type J, Relay1: On-Off Control Output, Relay2 / Alarm2: 350 °C High
3) Input: TC Type K, Profile Control (Ramp up to 400°C in 10 minutes and wait for 60 minutes), Relay1: PID Control Output, AO1: Retransmission Output (4-20 mA, 0-1200 °C)

Table 1. Input Type Options Type B Thermocouple Type E Thermocouple Type J Thermocouple Type K Thermocouple Type L Thermocouple Type N Thermocouple Type R Thermocouple Type S Thermocouple Type T Thermocouple Type U Thermocouple Pt-100 0-20 mA 4-20 mA 0-50 mV 0-1 V 0.2-1 V 0-10 V (*) 2-10 V (*)
(*) Custom specified volt input
Table 2. Control Set Options Internal adjustment with keys With Profile Control
Table 3. Alarm Options Off Low Alarm High Alarm Low Deviation High Deviation Band Alarm (In) Band Alarm (Out)

Table 4. Control Type Options No Control Single (Heat) Double (Heat/Cool) Floating Control of Valve
Tablo 5. Relay Output Options PID + (Heating) PID - (Cooling) On-Off + (Heating) On-Off - (Cooling) Alarm 1 Alarm 2 Alarm 3 Alarm 4
Table 6. Analog Output Options PID + (Heating) PID - (Cooling) Process Value Control Set Value
Table 7.1. Analog Output Range 0-20 mA 20-0 mA 4-20 mA 20-4 mA
Table 7.2. Analog Output Range 0-10 V 10-0 V 2-10 V 10-2 V

For detailed information, you can access the comprehensive user manual of the device under the heading "User Manuals" at www.elimko.com.tr. You can also use the QR Code on the front for this.
Elimko Elektronik malat ve Kontrol Ticaret Ltd. ti. Ankara Sanayi Odasi 2. Organize Sanayi Bölgesi Alci OSB Mahallesi 2001. Cad. No:14 Temelli 06909 Ankara / TURKYE
Tel: +90 312 212 64 50 (Pbx) · Fax: +90 312 212 41 43 · E-mail: elimko@elimko.com.tr · www.elimko.com.tr


Microsoft: Print To PDF