Owner's Manual for Elimko models including: E48, 48P, KY-48P-0324-1, E-48P Series Universal Advanced Digital Controllers, E-48P Series, Universal Advanced Digital Controllers, Advanced Digital Controllers, Digital Controllers, Controllers
User Manuels - Elimko - Reliable Name in Automatic Control
KY-48P-0324-1 4. WARNINGS E-48P Series Universal Advanced Digital Controllers R1 Quick Start Guide R2 Manufacturer / Technical Support Elimko Elektronik malat ve Kontrol Ltd. ti. 8. Cadde 21. Sokak No:16 Emek 06510 Ankara / TÜRKYE Telefon: + 90 312 212 64 50 Faks: + 90 312 212 41 43 48P www.elimko.com.tr · e-mail:elimko@elimko.com.tr 1. DESCRIPTION E-48P Series universal process controllers are industrial devices at 48x48 mm IEC/TR 60668 dimensions designed using new generation microcontrollers with on/off, PID and other control forms, where inputs and outputs can be easily programmed by the user. In E-48P Series controllers, the set value and measured value can be displayed from -1999 to 9999 on two 4-digit displays; general purpose inputs (T/C, R/T, mV, mA) can be programmed. 2. DIMENSIONS and PANEL CUT-OUT 48 mm R1 R2 48P K on trol Edilmitir 2 TP : E48 SKALA : GR : ÇIKI : SER NO : 21/14798 Tel: +90 3122126450 Fax: +90 3122124143 TÜ RKYE 44 mm -0.0 45 x 45 mm +0.5 10 mm min. 35 mm min. Panel Cut-Out and Minimum Spacing 3. CONNECTION DIAGRAM RL1 13 RL2 14 01 06 SSR2 02 SSR1 07 03 08 Operating voltage suitable for the device type shall be applied. RL3 04 09 AO1 05 11 12 10 RS 485 1st and 2nd control outputs can be selected as either Relay (RL1, RL2) or SSR (SSR1, SSR2). Only one of analog output (AO1) and RS-485 can be selected. Analog output (AO1) mA or 0-10 V DC can be selected. Analog Input 06 06 07 07 08 08 09 09 10 10 06 06 07 07 08 08 09 09 10 10 06 07 08 09 V 10 E-48P controller is designed for panel mounting and should be used in an industrial environment. The package of E-48P controller conta ns; Controller, 2 p eces of mount ng clamps, User manual and Guarantee cert f cate. After open ng the package, please check the contents w th the above l st. If the del vered product s wrong type, any tem s m ss ng or there are v s ble defects, contact the vendor from wh ch you purchased the product. Before nstall ng and operat ng the controller, please read the user manual thoroughly. The nstallat on and conf gurat on of the controller must only be performed by a person qual f ed n nstrumentat on. Keep the un t away from flamable gases, that could cause explos on. Do not use alcohol or other solvents to clean the controller. Use a clean cloth soaked n water t ghtly squeezed to gently w pe the outer surface of the controller. It s not used n med cal appl cat ons. EU DIRECTIVE COMPLIANCE Low Voltage D rect ve EN 61010-1 EMC D rect ve EN 61326-1 K - Q TSE-ISO-EN 9000 TS EN ISO 9001 Quality Management System Certificate 5. TYPE CODING E-48 Series Universal Advanced Controller E-48 - W - X - Y - Z Relay Outputs None 0 1 relay (RL1) 1 2 relays (RL1, RL2) 2 3 relays (RL1, RL2, RL3) 3 1 SSR (SSR1) 4 1 SSR (SSR1) + 1 relay (RL2) 5 1 SSR (SSR1) + 2 relay (RL2, RL3) 6 2 SSR (SSR1, SSR2) 7 2 SSR (SSR1, SSR2) + 1 relay (RL3) 8 Analog Outputs * None 0 0-20 / 4-20 mA (AO1) 1 0-10 V DC (AO1) 2 Communication None 0 RS-485 ** 1 Operating Voltage 85-265 V AC / 85-375 V DC 0 20-60 V AC / 20-60 V DC 1 * Only one of the relay 3 output, Analogue output and RS485 Modbus options can be coded. For example, only one of the (X) and (Y) options can be coded as 1. Similarly, when the (W) option includes Relay 3 (W=3, 6 or 8) X and Y 1 cannot be selected. ** When E-48 Series controllers are ordered with communication, the E-IB-11 USB-RS485 converter can be used for PC connection. There are various control and monitoring software provided by Elimko. 6. TECHNICAL SPECIFICATIONS Parameter Description Control Type On/Off, PID, Heat/Cool, Floating and Feedback Control of Valves Operating Voltage 20..60 V AC / 20..60 V DC or 85..265 V AC / 85..375 V DC Relays / SSR 2 pieces SPST - NO 250 V AC 5A relays or 24 V DC 25 mA (SSR) drives Dimensions (mm) 48 (Lenght) x 48 (Height) x 100 (Width) Panel Cut-Out (mm) 45 (Lenght) x 45 (Height) Analog Output 1 x 0..20 / 4..20 mA or 0..10 V DC optional Analog Input Universal (Note 1), Communication (RS-485) Available (RS-485) Digital Input None Valve Feedback None Transmitter Supply Available Weight 115 g Power Consumption Max. 7 W (10 VA) Operating Temperature - 10 °C ... 55 °C Storage Temperature - 25 °C ... 65 °C Memory Maks. 100.000 write Protection Class IP-65 Front Panel, IP-20 Rear Case Notes: (1) Universal Input : Thermocouple : B, E, J, K, L, N, R, S, T, U Resistance Thermometer : Pt-100 Current : 0-20 mA, 4-20 mA (Linear) Voltage : 0-50 mV, 0-1 V, 0.2- 1 V (Linear), 0-10 V DC, must be specified in the order. Resolution : 16 bit Accuracy : Thermocouple, Max. ±1.0 °C (Conversion and CJC error) Resistance Thermometer, Max. ±0.5 °C (Conversion and wire resistance compensation) Linear Input, Max. % 0.1 7. PARAMETER TABLE Description Analog Input 1 Type Decimal Point Analog Input 1 Linear Scale Lower Value Analog Input 1 Linear Scale Upper Value Temperature Unit Analog Input 1 Offset Value Analog Input 1 Filter Analog Input 1 Sensor Broken Behaviour Modbus Adress Modbus Baud Rate [ kbaud] Modbus Parity [ ] Min Maks Unit Table 1 0 3 -199.9 999.9 EU -199.9 999.9 EU -100.0 100.0 EU 1 15 s 1 127 Control Set Point Source Control Set Point Lower Limit Control Set Point Upper Limit Control Set Point Ramping Rate 1. Step Set Value 1. Step Time 2. Step Set Value 2. Step Time 3. Step Set Value 3. Step Time Table 2 -199.9 EU 999.9 EU 60.0 EU/min EU 999.9 min EU 999.9 min EU 999.9 min Alarm 1 Type Alarm 1 Set Point Alarm 1 Hysteresis Alarm 1 Lock Alarm 2 Type Alarm 2 Set Point Alarm 2 Hysteresis Alarm 2 Lock Alarm 3 Type Alarm 3 Set Po nt Alarm 3 Hysteres s Alarm 3 Lock Control Type Control Form [ ] Control Period Manual Mode Selection Floating Control Valve Travel Time Dead Band Control Output Lower Limit Control Output Upper Limit Control Output Manual Reset PID Power On Behaviour Retransmission Scale Lower Value Retransmission Scale Upper Value Relay 1 Function Relay 2 Function Relay 3 Funct on Analog Output 1 Function Analog Output 1 Type PID Auto Tune PID Parameter Type Proportional Band + Proportional Band Integral Time + Integral Time Derivative Time + Derivative Time Hysteresis Table 3 -199.9 999.9 EU 0.0 999.9 EU Table 3 -199.9 999.9 EU 0.0 999.9 EU Table 3 -199.9 999.9 EU 0.0 999.9 EU Table 4 1 250 s 10 2500 s 0.1 25.0 % 0.0 % 100.0 % % 0 4 -199.9 EU 999.9 EU Table 5 Table 5 Table 5 Table 6 Table 7.1 ve Table 7.2 0.1 999.9 EU 0.1 999.9 EU 9999 s 9999 s 2500 s 2500 s 0.0 999.9 EU Security Code Parameter Access Level Parameter Setting Level Factory Settings [ ] 0 9999 0 9 0 9 8. ACCESSING PARAMETERS STEP 1: STEP 2: Security Code Configuration Entry Page Selection (Default: 10) and Entry STEP 3: Parameter Selection and Configuration Process Screen Selected Page Parameters . . . Adjustment Enter Return Menu Access 9. APPLICATION EXAMPLES 1) Input: Pt-100 Relay / Alarm1: 50 °C Low, Relay2 / Alarm2: 55 °C High AO1: 4-20 mA PID Control Output 2) Input: TC Type J, Relay1: On-Off Control Output, Relay2 / Alarm2: 350 °C High 3) Input: TC Type K, Profile Control (Ramp up to 400°C in 10 minutes and wait for 60 minutes), Relay1: PID Control Output, AO1: Retransmission Output (4-20 mA, 0-1200 °C) Table 1. Input Type Options Type B Thermocouple Type E Thermocouple Type J Thermocouple Type K Thermocouple Type L Thermocouple Type N Thermocouple Type R Thermocouple Type S Thermocouple Type T Thermocouple Type U Thermocouple Pt-100 0-20 mA 4-20 mA 0-50 mV 0-1 V 0.2-1 V 0-10 V (*) 2-10 V (*) (*) Custom specified volt input Table 2. Control Set Options Internal adjustment with keys With Profile Control Table 3. Alarm Options Off Low Alarm High Alarm Low Deviation High Deviation Band Alarm (In) Band Alarm (Out) Table 4. Control Type Options No Control Single (Heat) Double (Heat/Cool) Floating Control of Valve Tablo 5. Relay Output Options PID + (Heating) PID - (Cooling) On-Off + (Heating) On-Off - (Cooling) Alarm 1 Alarm 2 Alarm 3 Alarm 4 Table 6. Analog Output Options PID + (Heating) PID - (Cooling) Process Value Control Set Value Table 7.1. Analog Output Range 0-20 mA 20-0 mA 4-20 mA 20-4 mA Table 7.2. Analog Output Range 0-10 V 10-0 V 2-10 V 10-2 V For detailed information, you can access the comprehensive user manual of the device under the heading "User Manuals" at www.elimko.com.tr. You can also use the QR Code on the front for this. Elimko Elektronik malat ve Kontrol Ticaret Ltd. ti. Ankara Sanayi Odasi 2. Organize Sanayi Bölgesi Alci OSB Mahallesi 2001. Cad. No:14 Temelli 06909 Ankara / TURKYE Tel: +90 312 212 64 50 (Pbx) · Fax: +90 312 212 41 43 · E-mail: elimko@elimko.com.tr · www.elimko.com.trMicrosoft: Print To PDF