INSTALLATION INSTRUCTIONS FOR OPTIONAL ELECTRIC ELEMENT PA01005 15 kW PA01055 18 kW PA01105 20 kW CADDY FURNACE Verified and tested for Canada and the United States by an accredited laboratory. This manual is available for free download on the manufacturer's web site. It is a copyrighted document. Resale is strictly prohibited. The manufacturer may update this manual from time to time and cannot be responsible for problems, injuries, or damages arising out of the use of information contained in any manual obtained from unauthorized sources. Eco-energy at the hearth of your home PSG 250, de Copenhague, St-Augustin-de-Desmaures (Quebec) CANADA G3A 2H3 Printed in Canada 45832A 2024-06-26 OPTIONAL ELECTRIC ELEMENT INSTALLATION Your Caddy furnace can be installed with an optional electric element (15 kW, 18 kW or 20 kW). This option can be installed on either side of your furnace. Installation must be done by a qualified technician. Please note that the installation procedure is carried out in an identical way no matter which electric element is used or the chosen installation side (right or left). Right side installation 2 Left side installation Remove cover for the electrical unit option (A) located on the desired side of the furnace by lifting the panel upward slightly and then pulling it toward you. You may dispose of the cover. Remove the cover (C) of the electric element (B) by removing eight (8) screws (D). Keep the screws. 3 Choose on which side the power is supplied to the electric element. Remove the knockout on the chosen side and the middle one using a screwdriver. Install a BX connector (E and F) in each opening (not provided). The middle opening is used to connect the power board of the furnace. 4 Connect the main power supply to terminals L1, L2, N and G located on the electrical element using the largest opening. (See Table "Technical data Electric Mode"). 5 Install the electric element (B) in the furnace. Screw it in place with six (6) screws. Remove the furnace knockout on the side where the electrical element is installed (1). Install a grommet (not included) (2). 6 Use two wires (18ga) (not included). Skinned at both ends. Connect the two wires on the terminal of the electrical element. Pass them through the BX connector (3) and in the grommet of the furnace (4). 7 Remove the cover of the power board which is in the fan box (5). Connect the wires of the electric element on the terminal "EHT" of the power board (6). Replace the electric element cover (C) using the screws (D) kept earlier. 8 Please note that in order to use a single circuit breaker for the electrical unit and the power board; it is possible to hook up the power board from the electric element. When supplying the power of the power board from the electrical element, always use the inline fuse that is included with the electric element box. TECHNICAL DATA ELECTRIC MODE MODEL OUTPUT (CFM) 15 kW 18 kW 20 kW 950 1,300 950 1,300 950 1,300 TEMP. VAR. (OF) 50 36 60 44 67 49 BTU/H 51,195 61,434 68,260 TOTAL AMPERAGE 75 87 95 BREAKER ALIMENT. CALIBRE VOLTAGE 1 PHASE # OF ÉLÉMENTS 100 4 120/240 3 5 kW 125 4 120/240 2 5 kW, 2 4 kW 125 3 120/240 4 5 kW 9 WIRING DIAGRAM FOR ELECTRIC UNIT 10Microsoft Word pour Microsoft 365