User Manual for Z-Wave models including: Z-Wave, Smart, Door Lock, GKDL-5100Z
This product is a secure electronic door lock that supports the Z-Wave PlusTM standard, which is compatible with earlier versions of Z-WaveTM. This product can be included and operated in any Z-Wave network with other Z-Wave certified
GKDL-5100Z Smart Door Lock Manual Ver 1.0 This product is a secure electronic door lock that supports the Z-Wave PlusTM standard, which is compatible with earlier versions of Z-WaveTM. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. The device can be included in the Z-Wave network using S0 or S2 Access Control security. Inclusion can be via standard inclusion, SmartStart: Z-Wave Specifications Device Type : Door Lock (SPECIFIC_TYPE_ DOOR_LOCK) Role Type : LSS (Listening Sleeping Slave) Command Cass Support/Control Standard Network Inclusion / Exclusion Please proceed with the door lock open. To add or include this product into a Z-Wave network 1. Set the controller in inclusion mode. 2. Open the battery cover of the indoor body and press the [REG] button. 3. Press the Master Pin [1][2][3][4] (Default value) button after pressing the [#] button. 4. Press the [8][8] button after pressing the [#] button. 5. If the controller supports S2 security, you will be prompted to enter the first 5 digits of the DSK to complete the authentication, known as the Pin Code.(You can check the DSK and QR code by removing the battery cover of the product or package box) To remove or exclude the GKBC-3100Z into a Z-Wave network 1. Set the controller in exclusion mode. 2. Open the battery cover of the indoor body and press the [REG] button. 3. Press the Master Pin [1][2][3][4] (Default value) button after pressing the [#] button. 4. Press the [9][9] button after pressing the [#] button. SmartStart SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the StartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. (You can check the DSK and QR code by removing the battery cover of the product or package box) Factory Reset Please proceed with the door lock open. Please use this procedure only when the primary controller is missing or otherwise inoperable. To Factory Reset 1. Open the battery cover of the indoor body and press the [REG] button. 2. Press the Master Pin [1][2][3][4] (Default value) button after pressing the [#] button. 3. Press the [7][7] button after pressing the [#] button. Battery Information 4 AA Alkaline 1.5V Batteries(6V) Supported Command Class Command Class Version Not added Z-Wave Plus INFO 2 TRANSPORT SERVICE 2 SECURITY 0 1 SECURITY 2 2 ASSOCIATION 2 ASSOCIATION GRP INFO 3 BATTERY 1 DEVICE RESET LOCALLY 1 DOOR LOCK 4 FIRMWARE UPDATE MD 5 MANUFACTURE SPECIFIC 2 NOTOFICATION 8 POWERLEVEL 1 SUPERVISION 1 USER CODE 2 VERSION 2 INDICATOR 3 CONFIGURATION 3 Support Support Support Support Non-Secure added Support Support Support Support Securely added Non-secure CC Secure CC Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Association(V2) & Association Group Information(V1) - The product supports one association groups: -> Group 1 is the Lifeline group. It can contain up to 5 nodes. The Lifeline group on this lock is used to report door lock operation report, and device reset locally notifications to nodes on the group list. Battery CC(V1) The Battery Get request can be used to get the status of the battery. When battery level is low a battery warning is sent to the controller. Door Lock(V4) - Door Lock Operation is used to lock and unlock this product. 1) To Lock : Sending command class = COMMAND_CLASS_DOOR_LOCK, command = DOOR_LOCK_OPERATION_SET, mode = 0xFF (DOOR_SECURED) or BASIC_SET value 0xFF will lock the door. Notification Type Access Control, Event 0x03 (RF lock operation) is sent to the Lifeline and then one second later, a Door Lock Operation Report is sent to the Lifeline. 2) To Unlock: Sending command class = COMMAND_CLASS_DOOR_LOCK, command = DOOR_LOCK_OPERATION_SET, mode = 0x00 (DOOR_UNSECURED) or BASIC_SET value 0x00 will unlock the door. Notification Type Access Control, Event 0x04 (RF unlock operation) is sent to the Lifeline and then one second later, a Door Lock Operation Report is sent to the Lifeline. - See table to see how the Door Lock Mode parameter affects the lock. Secured Unsecured Door Lock Mode 0xFF 0x00 In a Door Lock Operation Report the GKBC-3100Z will report. Door Status Unlocked Locked Door Lock Mode 0x00 0xFF Handles 0x00 0x00 Door Condition Bit 0 : Door Bit 1 : Deadbolt 0 : Open, 1 : Close 0 : Locked, 1 : Unlocked Lock Timeout Minutes 0xFE Lock Timeout Seconds 0xFE Firmware Update Meta Data(V5) The GKBC-3100Z supports firmware update of the Z-Wave module over the air. The firmware upgrade takes ~20 min with S0 and ~20 min with S2 Firmware ID = 0x0102. Firmware 0 ID = 0x0101. Manufacture Specific(V2) Value Manufacturer ID 0x037B Product Type ID 0x0010 Product ID 0x0001 Comment KeyWe Inc. GKDL-5000Z DoorLockKeyPad Notification(V8) The Notification CC is implemented as a push only, which means only pushes notification to the controller. Sequence number is not supported. Supported notifications Notification Type Event State Parameters Comments 0x01 Manual lock operation (Knob, Key, Button). 0x02 Manual unlock operation (Knob, Key, Button). 0x03 0x01 : Z-Wave 0x02 : BLE RF lock operation (Z-Wave, Bluetooth, Remote controller) 0x04 0x01 : Z-Wave 0x02 : BLE 0x03 : Remote Controller RF unlock operation (Z-Wave, Bluetooth, Remote controller) 0x05 User Keypad lock operation Access Control (0x06) 0x06 MASTER : 0x00 USER : 0x01 ~ 0x64 User Keypad unlock operation 0x09 Auto lock locked operation 0x0B Lock jammed. Emergency Alarm (0x0A) 0x0C 0x0D 0x0E 0x0F 0x01 MASTER : 0x00 USER : 0x01 ~ 0x64 MASTER : 0x00 USER : 0x01 ~ 0x64 MASTER : 0x00 USER : 0x01 ~ 0x64 0x02 All user codes deleted. Single user code deleted New user code added. New user code not added due to duplicated code. Contact police Contact fire service Power Level(V1) Can be used under inclusion to test signal strength from the controller and to the device. Security(V1) See Z-Wave documentation. Security(V2) This product support S2_ACCESS security class. Supervision(V1) See Z-Wave documentation. Transport Service(V2) See Z-Wave documentation. User Code(V2) Lock will accept maximum 100 pin codes that has 4-10 digits in length. - Support Users : 100 - ID Range : 1 ~ 100 Version(V2) This command Class is used to get information about which version of the different command classes the GKBC-3100Z supports and the software version of the GKBC-3100Z. Version Report Z-Wave Library Type ZW_LIB_SLAVE_ENHANCED(0x03) Z-Wave Protocol Version 0x07 (SDK v7.12.02) Z-Wave Protocol Sub Version 0x0C (SDK v7.12.02) 1) Firmware 0 Version Version of the firmware on the Z-Wave module Version Subversion Comments 1 0 First Release 2) Firmware 1 Version Version of the firmware on the Host Version Subversion Comments 1 0 First Release 3) Hardware Version 0x01 GKDL-5100Z Z-Wave Plus Info(V2) Z-WAVE Plus Info Role Type 0x07 ROLE_TYPE_SLAVE_SLEEPING_LISTENING Node Type 0x00 NODE_TYPE_ZWAVEPLUS_NODE Icon Type 0x0300 ICON_TYPE_GENERIC_DOOR_LOCK_KEYPAD User Icon Type 0x0300 ICON_TYPE_GENERIC_DOOR_LOCK_KEYPAD Product Wake up To wake up the product, the following actions are required. 1. Touch the keypad on outdoor body. 2. Push the button on Indoor body. 3. Turn the knob on Indoor body. Configuration Parameters Parameter 1: Name : VOLUME Description : It means door lock's volume Default : 0x02 (Normal) Min : 0x01 Max : 0x03 Parameter 2: Name : DOOR LOCK MODE Description : It means door lock's locking mode(auto/manual) Default : 0x01 (auto) Min : 0x01 Max :0x02 Parameter 3: Name : RE-LOCK TIME Description : It means door lock's re-lock time Default : 0x07 (7 seconds) Min : 0x01 Max : 0x1EMicrosoft Word Microsoft 365용