Product Identification
Product Name: AUREA - module LED
The product is an LED lighting module for indoor luminaires, with the commercial reference 555001.
Technical Description: Module LED du brasseur d'air AUREA (AUREA air circulator LED module), a silent air circulator (<42db) equipped with an LED board. Color: White.
Components Supplied: Polycarbonate Diffuser (Direct/Symmetric Opalescent), LED module body in aluminum.
Key Technical Characteristics:
- Light Source: Integrated LED module
- Number of Light Sources Required: 1 (over the luminaire's reference life)
- Control Gear: Integrated
- Number of Control Gear Required: 1 (over the luminaire's reference life)
- Luminous Flux: 1500 lumens
- Nominal Operating Voltage: 220-240 V
- Color Temperature: 4000 K
- IP Rating: 20
- IK Rating: 6
- Luminous Efficacy: 91 lm/W
- Power: 16.5 W
- Assigned Lifetime: 50000 h
- Luminaire Usage Duration: 14.3 years
- Application: Interior / Residential Buildings
- Product Mass: 0.3138 kg
- Packaging Mass: 0 kg
- Geographical Representativeness: Manufacturing in China. Distribution, installation, use, and end-of-life in France.
- Temporal Representativeness: Manufacturing data representative of 2025.
Functional and Declared Units
Functional Unit: To provide lighting delivering an artificial luminous flux reduced to 1000 lumens over a reference life of 35,000 hours.
The reference flux is defined as one product unit divided by 0.467.
Declared Unit: A luminaire providing an output luminous flux of 1500 lumens over a reference life of 14.2857142857143 years.
Constituent Materials
The total product mass is 0.3138 kg (0.3138 kg product, 0 kg packaging). At the reference flow scale, the total product mass is 0.1465446 kg.
Constituent Materials | Metals | Plastics | Others | |||||
---|---|---|---|---|---|---|---|---|
Aluminium | 65.3% | Polycarbonate (PC) | 9.5% | Plain wood; for pallet | 2.4% | |||
Copper | 7.9% | Polyethylene high density (HDPE) | 6.8% | Cardboard | 1.9% | |||
Ferrites | 0.5% | Epoxy resin | 2.0% | Paper | 1.5% | |||
Stainless steel with chrome | 0.3% | Polyethylene low density (LDPE) | 0.5% | Raw materials | 0.1% | |||
Silicone rubber | 0.3% | |||||||
Polyester resin | 0.2% | |||||||
Phenolic resin | 0.1% | |||||||
Divers | 0.2% | Divers | <0.1% | Divers | <0.1% | |||
Total | 74.2% | Total | 19.7% | Total | 6.1% |
Additional Environmental Information
Fabrication: The AUREA LED module is designed in compliance with RoHS Directive (2011/65/EU), restricting the use of lead, mercury, cadmium, hexavalent chromium, and flame retardants (PBB, PBDE).
Distribution: Packaging mass and volume have been optimized based on European packaging directives, reducing plastic use in favor of recycled and recyclable cardboard.
Installation: The AUREA LED module requires mounting on the AUREA air circulator. Installation is manual, with all necessary screws provided.
Use: Verify installation before operation.
End of Life: Resistex is affiliated with the ecosystem eco-organization for the recycling and recovery of all WEEE (Waste Electrical and Electronic Equipment). A service in collaboration with ecosystem is available for free WEEE collection.
Life Cycle Analysis Methodology
The Life Cycle Analysis (LCA) underpinning this Product Environmental Profile (PEP) follows criteria set by PCR-ed4-FR-2021 09 06 of the PEP ecopassport® Program. The functional unit and scenarios for distribution, use, and waste treatment comply with hypotheses defined in PSR-0014-ed2-FR-2023 07 13. Results were obtained using EIME software version 6.2 with its April 2024 database.
Life Cycle Stages
Manufacturing Stage: Luminaires are assembled at the RESISTEX factory in China. This stage includes raw material production and transport, industrial processes, assembly (energy, gas, water consumption; waste from scraps/packaging), waste treatment, and transport of the packaged product to the final logistics platform. Recycled content is considered 0%.
- Energy Model: Electricity Mix; Low voltage; 2022; China, CN.
Distribution Stage: Product distribution from the logistics platform (Saint André de la Roche, France) to installation sites in France was modeled using truck transport (250 km) and container ship transport (19000 km), following the local/national transport scenario from PEP-PCR-ed4-EN-2021 09 06.
- Energy Model: Electricity Mix; Production mix; Low voltage; 2022; France, FR.
Installation Stage: Manual installation; all necessary screws are supplied. The packaging's end-of-life is considered.
Use Stage: The luminaire has no lighting management function. It is used for 14.2857142857143 years with 3500 hours/year, totaling 50000 hours. With a power of 16.5W, its lifetime electricity consumption is 825 kWh. No light source replacement or maintenance is required during its lifetime.
- Energy Model: Electricity Mix; Production mix; Low voltage; 2022; France, FR.
End-of-Life Stage: This stage includes the transport and treatment of the luminaire and its light source. It was modeled using EcoSystem's ESR database for electrical and electronic equipment end-of-life impacts. ESR data without virgin material substitution benefits were used, categorized under "Professional Lighting Equipment".
- Energy Model: Electricity Mix; Production mix; 2015-2017; France, FR (Ecosystem).
Module D - Net Benefits and Charges Beyond System Boundaries
Charges related to recycled material in manufacturing and benefits from packaging recycling and end-of-life recycling are considered.
Environmental Impacts (Unitary Functional Level)
The following table presents the environmental impacts calculated for the reference product at the scale of the unitary functional level (1000 lumens for 35,000 hours), based on PCR-ed4-FR-2021 09 06 and PSR-0014-ed2-FR-2023 07 13.
Impact Indicator | Unit | Fabrication (A1-A3) | Distribution (A4) | Installation (A5) | Use (B1-B7) | Fin de Vie (C1-C4) | Total (incl. D) | Benefits and Charges (D) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
B1 | B2 | B3 | B4 | B5 | B6 | B7 | |||||||||
Climate change - total | kg CO2 eq | 2.63E+00 | 1.47E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.47E+01 | 0.00E+00 | 3.47E+01 | 1.36E-01 | 3.74E+01 | -8.83E-01 |
Climate change - fossil fuels | kg CO2 eq | 2.54E+00 | 1.47E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.27E+01 | 0.00E+00 | 3.27E+01 | 1.32E-01 | 3.54E+01 | -8.73E-01 |
Climate change - biogenic | kg CO2 eq | 8.41E-02 | 1.06E-07 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.94E+00 | 0.00E+00 | 1.94E+00 | 4.25E-03 | 2.03E+00 | -1.02E-02 |
Climate change - land use | kg CO2 eq | 3.72E-05 | 3.90E-08 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.34E-08 | 3.72E-05 | 0.00E+00 |
Ozone depletion | kg CFC-11 eq | 4.26E-07 | 3.06E-10 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.84E-07 | 0.00E+00 | 3.84E-07 | 1.17E-08 | 8.22E-07 | -1.77E-08 |
Acidification | mol H+ eq | 2.24E-02 | 3.70E-05 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.62E-01 | 0.00E+00 | 1.62E-01 | 9.57E-04 | 1.86E-01 | -1.13E-02 |
Eutrophication freshwater | kg P eq | 1.40E-05 | 9.58E-08 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.08E-03 | 0.00E+00 | 1.08E-03 | 6.11E-07 | 1.10E-03 | -8.42E-04 |
Eutrophication marine | kg N eq | 1.89E-03 | 5.56E-06 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 2.23E-02 | 0.00E+00 | 2.23E-02 | 4.64E-04 | 2.47E-02 | -9.65E-04 |
Eutrophication terrestrial | mol N eq | 2.13E-02 | 6.11E-05 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.73E-01 | 0.00E+00 | 3.73E-01 | 1.26E-03 | 3.96E-01 | -1.13E-02 |
Photochemical Ozone Formation | kg COVNM eq | 6.87E-03 | 2.01E-05 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 6.54E-02 | 0.00E+00 | 6.54E-02 | 3.75E-04 | 7.27E-02 | -3.14E-03 |
Abiotic Resource Depletion - elements | kg Sb eq | 1.27E-04 | 1.02E-08 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.90E-05 | 0.00E+00 | 3.90E-05 | 2.98E-07 | 1.66E-04 | -8.48E-05 |
Abiotic Resource Depletion - fossil fuels | MJ | 4.78E+01 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 4.55E+03 | 0.00E+00 | 4.55E+03 | 2.03E+00 | 4.60E+03 | -9.94E+00 |
Water Consumption | m3 eq | 6.80E-01 | 9.48E-04 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 6.36E+00 | 0.00E+00 | 6.36E+00 | 1.68E+01 | 2.39E+01 | -4.03E+02 |
Inventory Flows
Inventory Flow | Unit | Fabrication (A1-A3) | Distribution (A4) | Installation (A5) | Use (B1-B7) | Fin de Vie (C1-C4) | Total | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
B1 | B2 | B3 | B4 | B5 | B6 | B7 | ||||||||
Use of renewable energy, excl. raw materials | MJ | 3.27E+00 | 1.45E-03 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 5.16E+02 | 0.00E+00 | 5.16E+02 | 1.18E-01 | 5.20E+02 |
Use of renewable energy resources as raw materials | MJ | 1.22E-01 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.22E-01 |
Total use of renewable energy | MJ | 3.39E+00 | 1.45E-03 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 5.16E+02 | 0.00E+00 | 5.16E+02 | 1.18E-01 | 5.20E+02 |
Use of non-renewable energy, excl. raw materials | MJ | 4.63E+01 | 4.57E-01 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 4.55E+03 | 0.00E+00 | 4.55E+03 | 2.03E+00 | 4.60E+03 |
Use of non-renewable energy resources as raw materials | MJ | 1.50E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.50E+00 |
Total use of non-renewable energy | MJ | 4.78E+01 | 4.57E-01 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 4.55E+03 | 0.00E+00 | 4.55E+03 | 2.03E+00 | 4.60E+03 |
Use of secondary materials | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Use of secondary renewable fuels | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Use of secondary non-renewable fuels | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Net freshwater use | m³ | 1.58E-02 | 2.21E-05 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.58E-02 |
Hazardous waste | kg | 3.26E+00 | 1.08E-04 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.26E+00 |
Non-hazardous waste | kg | 4.99E+00 | 2.40E-03 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 4.99E+00 |
Radioactive waste | kg | 3.97E-03 | 1.90E-06 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.97E-03 |
Components for reuse | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Materials for recycling | kg | 3.71E-05 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.71E-05 |
Materials for energy recovery | kg | 6.17E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 6.17E-02 |
Energy supplied externally | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Environmental Impacts (Equipment Level)
The following table presents the environmental impacts calculated for the product at the equipment level (for 1 luminaire of 1500 lumens over 50000 hours). These impacts are obtained by multiplying the unitary functional impacts by 2.14.
Impact Indicator | Unit | Fabrication (A1-A3) | Distribution (A4) | Installation (A5) | Use (B1-B7) | Fin de Vie (C1-C4) | Total (incl. D) | Benefits and Charges (D) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
B1 | B2 | B3 | B4 | B5 | B6 | B7 | |||||||||
Climate change - total | kg CO2 eq | 5.63E+00 | 3.14E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 7.42E+01 | 0.00E+00 | 7.42E+01 | 2.92E-01 | 8.02E+01 | -1.89E+00 |
Climate change - fossil fuels | kg CO2 eq | 5.45E+00 | 3.14E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 7.01E+01 | 0.00E+00 | 7.01E+01 | 2.83E-01 | 7.58E+01 | -1.87E+00 |
Climate change - biogenic | kg CO2 eq | 1.80E-01 | 2.26E-07 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 4.15E+00 | 0.00E+00 | 4.15E+00 | 9.11E-03 | 4.34E+00 | -2.17E-02 |
Climate change - land use | kg CO2 eq | 7.96E-05 | 8.36E-08 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 2.87E-08 | 7.97E-05 | 0.00E+00 |
Ozone depletion | kg CFC-11 eq | 9.12E-07 | 6.56E-10 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 8.22E-07 | 0.00E+00 | 8.22E-07 | 2.51E-08 | 1.76E-06 | -3.79E-08 |
Acidification | mol H+ eq | 4.80E-02 | 7.93E-05 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.47E-01 | 0.00E+00 | 3.47E-01 | 2.05E-03 | 3.97E-01 | -2.41E-02 |
Eutrophication freshwater | kg P eq | 2.99E-05 | 2.05E-07 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 2.32E-03 | 0.00E+00 | 2.32E-03 | 1.31E-06 | 2.35E-03 | -1.80E-03 |
Eutrophication marine | kg N eq | 4.05E-03 | 1.19E-05 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 4.78E-02 | 0.00E+00 | 4.78E-02 | 9.94E-04 | 5.29E-02 | -2.07E-03 |
Eutrophication terrestrial | mol N eq | 4.57E-02 | 1.31E-04 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 7.99E-01 | 0.00E+00 | 7.99E-01 | 2.69E-03 | 8.48E-01 | -2.41E-02 |
Photochemical Ozone Formation | kg COVNM eq | 1.47E-02 | 4.31E-05 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.40E-01 | 0.00E+00 | 1.40E-01 | 8.04E-04 | 1.56E-01 | -6.71E-03 |
Abiotic Resource Depletion - elements | kg Sb eq | 2.72E-04 | 2.18E-08 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 8.35E-05 | 0.00E+00 | 8.35E-05 | 6.39E-07 | 3.56E-04 | -1.82E-04 |
Abiotic Resource Depletion - fossil fuels | MJ | 1.02E+02 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 9.74E+03 | 0.00E+00 | 9.74E+03 | 4.35E+00 | 9.84E+03 | -2.13E+01 |
Water Consumption | m3 eq | 1.46E+00 | 2.03E-03 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.36E+01 | 0.00E+00 | 1.36E+01 | 3.60E+01 | 5.11E+01 | -8.64E+02 |
Optional Environmental Indicators
Impact Indicator | Unit | Fabrication (A1-A3) | Distribution (A4) | Installation (A5) | Use (B1-B7) | Fin de Vie (C1-C4) | Total (incl. D) | Benefits and Charges (D) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
B1 | B2 | B3 | B4 | B5 | B6 | B7 | |||||||||
Total primary energy use | MJ | 1.10E+02 | 9.81E-01 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.08E+04 | 0.00E+00 | 1.08E+04 | 4.60E+00 | 1.10E+04 | -3.07E+01 |
Fine Particulate Matter Emissions | Décès/Kg eq PM2.5 | 3.77E-07 | 5.75E-10 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.14E-05 | 0.00E+00 | 1.14E-05 | 1.38E-08 | 1.18E-05 | -1.42E-07 |
Ionizing Radiation | kBq U235 eq | 4.16E+00 | 1.92E-03 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.27E+03 | 0.00E+00 | 1.27E+03 | 5.70E-02 | 1.27E+03 | -1.22E+00 |
Freshwater Ecotoxicity | CTUe | 3.94E+01 | 1.58E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.13E+02 | 0.00E+00 | 1.13E+02 | 2.13E+00 | 1.56E+02 | -4.16E+00 |
Human Toxicity (carcinogenic) | CTUh | 2.74E-08 | 1.06E-11 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 1.23E-08 | 0.00E+00 | 1.23E-08 | 2.15E-10 | 3.99E-08 | -2.42E-09 |
Human Toxicity (non-carcinogenic) | CTUh | 1.03E-07 | 1.38E-10 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.24E-07 | 0.00E+00 | 3.24E-07 | 9.90E-09 | 4.38E-07 | -1.84E-07 |
Land Use/Soil Quality | pas de dimension | 2.47E-01 | 2.37E-04 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 3.57E+00 | 0.00E+00 | 3.57E+00 | 1.57E+00 | 5.39E+00 | -1.14E+01 |
Extrapolation Rules
The 555001 luminaires are available in 6 versions belonging to the same homogeneous environmental family. The environmental impacts of other products in the range are estimated by weighting the environmental impacts of the reference product by extrapolation coefficients. The parameters for the different products in the range are as follows:
Product | Luminous Flux (lumens) | Power (W) | Energy Saving Coefficient | Product Mass (kg) | Structure Mass (kg) | Control Gear Mass (kg) | Light Source Mass (kg) | Lighting Control Mass (kg) | Packaging Mass (kg) |
---|---|---|---|---|---|---|---|---|---|
555001 - Reference | 1500 | 16.50 | 1.00 | 0.31 | 0.23 | 0.06 | 0.02 | 0.00 | 0.00 |
555020 | 1500 | 16.50 | 1.00 | 0.31 | 0.23 | 0.06 | 0.02 | 0.00 | 0.00 |
555022 | 1500 | 16.50 | 1.00 | 0.31 | 0.23 | 0.06 | 0.02 | 0.00 | 0.00 |
555024 | 1500 | 16.50 | 1.00 | 0.31 | 0.23 | 0.06 | 0.02 | 0.00 | 0.00 |
555026 | 1500 | 16.50 | 1.00 | 0.31 | 0.23 | 0.06 | 0.02 | 0.00 | 0.00 |
555028 | 1500 | 16.50 | 1.00 | 0.31 | 0.23 | 0.06 | 0.02 | 0.00 | 0.00 |
Extrapolation Coefficients at Unitary Functional Level:
Extrapolation coefficients are provided for the environmental impact of the functional unit (emission of 1000 lumens over 35,000 hours). For each life cycle stage, the environmental impacts of the considered product are calculated by multiplying the declaration impacts corresponding to the reference product by the extrapolation coefficient. The "Total" column is calculated by summing the environmental impacts of each life cycle stage.
Product | Fabrication | Distribution | Installation | Use | Fin de vie | Module D | |
---|---|---|---|---|---|---|---|
B2 | B6 | ||||||
555001 - Reference | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555020 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555022 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555024 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555026 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555028 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
Extrapolation Coefficients at Declared Unit Level:
Extrapolation coefficients are provided for the environmental impact of the declared unit (at equipment level). For each life cycle stage, the environmental impacts of the considered product are calculated by multiplying the declaration impacts corresponding to the reference product by the extrapolation coefficient.
Product | Fabrication | Distribution | Installation | Use | Fin de vie | Module D | |
---|---|---|---|---|---|---|---|
B2 | B6 | ||||||
555001 - Reference | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555020 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555022 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555024 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555026 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
555028 | 0.97 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.97 |
About Resistex
Resistex is a French family company founded in 1937, designing, manufacturing, and distributing innovative lighting solutions for tertiary and residential buildings, whether new or undergoing energy renovation. The company emphasizes its employees as its greatest asset.
The electrical installer is a historical client and partner. Resistex is committed to providing energy-efficient, personalized lighting solutions adapted to spaces and users, ensuring the "right light".
This commitment reflects Resistex's priorities: the importance of the end-user in the client system, the development of innovations for personalization, and a focus on green growth and energy transition.
Company Information
RESISTEX
Address: 11, Quai de la Banquière 06730 Saint André de la Roche
Tel: 04 93 27 62 76
Email: resistex@resistex-sa.com
Web: https://www.resistex-sa.com/fr/
PEP Sheet Model Developed in Collaboration With:
- Syndicat du luminaire - GIL (https://www.luminaire.org/)
- CODDE - Département du LCIE Bureau Veritas (www.codde.fr)