V-ZUG Error Message List

Model Series: CSN.60A,61A / CSS.62A,63A

Document Reference: K4.20676D-BB

1 Malfunctions with error code

Error Code Message (Through microcontroller) Diagnostic of error Possible cause 2)
E01 EEPROM Read error (after 50 tries) F5 1 Problems with processor, caused by moisture or EMC influences.
E02 EEPROM Write error (after 10 tries) F5 1 Problems with processor, caused by moisture or EMC influences.
E03 FLASH Incorrect process data (device ID number) F5 1 Loaded incorrect process data. Reload process data.
E04 FLASH Incorrect process data (checksum) F5 1 Process data error. Reload process data.
E05 FLASH Incorrect firmware (checksum) F5 1 Firmware error. Reload firmware or replace processor.
E06 SOFTWARE Watchdog reset 1 Processor faulty.
E07 ACTUATOR Logic error 1 Software error, disconnect device from the main supply and contact customer service.
E09 Cooking space temperature Sensor with too low a resistance (temp. < ca. -20°C) F0 1 Short circuit in PT sensor or in its wiring.
E10 Cooking space temperature Sensor with too high a resistance (temp. > ca. 800°C) F0 1 Break or loose contact in PT sensor or in its wiring.
E11 Cooking space temperature Reference with too low a resistance F0 1 Processor faulty.
E12 Cooking space temperature Reference with too high a resistance F0 1 Processor faulty.
E13 Cooking space temperature Temperature > 350°C during Off / Standby Mode 1 Electromagnetic disturbances → Replace processor.
2 Heating and main relay short circuited → Replace processor.
E17 3) Food temperature Food probe with too low a resistance (temp. > ca. 230°C) F1 1 Short circuit in food probe or in its wiring.
2 Food probe not inserted into food, tip too hot.
3 Moisture in food probe socket.
E18 3) Food temperature Food probe with too high a resistance (temp. < ca. -20°C) F1 1 Break or loose contact in food probe or in its wiring.
E25 Climate temperature Sensor with too low a resistance (temp. > ca. 265°C) F3 1 Short circuit in climate sensor or in its wiring.
2 Exhaust duct blocked.
3 Duct between cooking space and climate sensor blocked.
E26 Climate temperature Sensor with too high a resistance (temp. < ca. -2°C) F3 1 Break or loose contact in climate sensor or in its wiring.
2 Exhaust duct blocked.
3 Duct between cooking space and climate sensor blocked.
E27 Climate temperature Temperature > 190°C for 120 seconds F17 1 Hairline crack in climate sensor.
2 Excessive steam generation because of steam operation followed by top/bottom heat operation. Load new process with version index ≥2.
E29 Temperatur Klima temperature differential of less than 5°C during 180-second monitoring cycle (active monitoring only during first 20 minutes after start as well as with climate temperature of over 85°C) F9 1 Cooking space not tightly sealed (door not closed properly, exhaust slide valve not tight, food probe socket is defective).
2 Too much cold food in the cooking space (when steaming, weight of frozen food should not exceed 3kg).
3 Climate sensor plug dirty / wet.
4 Hot air fan seal is missing or faulty. To check: remove the hot air panel and rotor (caution: left-hand thread).
E33 Processor temperature Sensor with too low a resistance (temp. > ca. 200°C) F12 1 Processor faulty.
E34 Processor temperature Sensor with too high a resistance (temp. < ca. -16°C) F12 1 Processor faulty.
E35 Processor temperature Temperature > 85°C for 60 seconds F13 1 Niche temperature too high (caused by second appliance?).
2 Cool air fan failure.
3 Power failure during baking process.
E36 Control unit temperature Sensor with too low a resistance (temp. > ca. 200°C) F14 1 Control unit faulty.
E37 Control unit temperature Sensor with too high a resistance (temp. < ca. -16°C)) F14 1 Control unit faulty.
E38 Control unit temperature Temperature > 85°C for 120 seconds F15 1 Niche temperature too high (caused by second appliance?).
2 Cool air fan failure.
3 Power failure during baking process.
E41 Water temperature Sensor with too low a resistance (temp. > ca. 200°C) F2 1 Short circuit in water temperature sensor or in its wiring.
2 Boiler leaking water.
E42 Water temperature Sensor with too high a resistance (temp. < ca. -10°C) F2 1 Break or loose contact in water temperature sensor or in its wiring.
E44 Water temperature Increase in temperature to min. 80°C within 240 seconds (active monitoring only when temperature below 85°C) F7 1 Heating element for boiler is faulty. Over-temperature protection activated.
Boiler faulty
2 Relay on Processor defect,
Processor faulty
E49 Control unit Button(s) closed for min. 60 seconds F10 1 Button is mechanically blocked or jammed.
2 Moisture on the control unit.
E50 Control unit Moisture sensor closed for min. 20 seconds F10 1 Moisture on the control unit.
2 Cooking space not tight.
3 Cool air fan failure.
E51 Processor Relays defect F6 1 Processor faulty.
E52 Leaked water detection Leaked water detected for min. 10 seconds F10 1 Water in driptray at the waste water tank
2 Leakage in water system
3 Water tank valve not tight.
E54 Supplementary Board Communication error F25 1 Check connection (incl. cable) between Supplementary Board and Processor.
2 Supplementary Board faulty
3 Processor faulty
E55 Supplementary Board Hardware error 1 Supplementary Board faulty
E56 Supplementary Board Software incompatibility 1 Update firmware of processor
2 Supplementary Board faulty
E57 Mains connection Voltage on Neutral N > 340V U0 1 Faulty connection: Pole conductor connected to neutral conductor terminal.
2 Neutral conductor break in the house wiring system.
3 Mains calibration error (see error code E63).
E58 Mains connection L2 no signal U1 1 No pole conductor connected to L2 clamp.
2 Circuit breaker or fuse in house wiring system activated.
3 Processor faulty
E59 Mains connection Voltage > 270V for 1 second U0 1 Overvoltage in mains power supply.
2 Neutral conductor break in the house wiring system.
3 Mains calibration error (see error code E63).
E61 Mains connection Voltage < 170V for 1 minute U2 1 Undervoltage in mains power supply.
2 Mains calibration error (see error code E63).
E62 Mains connection Voltage < 150V U3 1 Undervoltage in mains power supply.
2 Mains calibration error (see error code E63).
E63 Mains calibration Calibration fault 1 Processor faulty.
E66 Water system If it has been a while since last descaling: Level detector pin with low resistance only after refilling (occuring at least 6 times consecutively) 1 Boiler scaled up.
E67 Water system If descaling was carried out recently: Level detector pin with low resistance only after refilling (occuring at least 6 times consecutively) 1 Boiler scaled up.
E68 Water system If it has been a while since last descaling: Pumping off water at least 3 times within 2 hours 1 Boiler scaled up.
2 Inlet valve leaking (valve not tight, limescale fragments in seal, etc.)
3 There could be foam in the boiler housing (especially after descaling).
E69 Water system If descaling was carried out recently: Pumping off water at least 3 times within 2 hours F21 1 Boiler scaled up.
2 Inlet valve leaking (valve not tight, limescale fragments in seal, etc.)
3 There could be foam in the boiler housing (especially after descaling).
E70 Water system If it has been a while since last descaling: Water is not continuing to be fed in during steaming 1 Boiler scaled up.
2 Inlet valve leaking (valve not tight, limescale fragments in seal, etc.)
E71 Water system If descaling was carried out recently: Water is not continuing to be fed in during steaming F22 1 Boiler scaled up.
2 Inlet valve leaking (valve not tight, limescale fragments in seal, etc.)
E72 Water system If it has been a while since last descaling: Level detector pin with high resistance again after pumping off water 5 times 1 Drain pump pumping off too little water.
2 Water conductivity too low.
3 Foam in boiler housing (unsuitable descaling agent).
E73 Water system If descaling was carried out recently: Level detector pin with high resistance again after pumping off water 5 times F23 1 Drain pump pumping off too little water.
2 Water conductivity too low.
3 Foam in boiler housing (unsuitable descaling agent).
E74 Water system Descaling error during descaling phase (appliance is blocked) 1 No descaler added.
2 Error in measurement of level (possibly due to formation of foam).
E75 Water system Descaling error during 1st rinsing phase (appliance is blocked) 1 No or insufficient amount of water for rinsing.
2 Excessive build-up of foam.
E76 Water system Descaling error during 2nd rinsing phase (appliance is blocked) 1 No or insufficient amount of water for rinsing.
2 Excessive build-up of foam.
E81 Relay calibration 1 No calibration of relay. → Replace processor.
E85 Slide motor Motor current shows short circuit F4 1 Short circuit in slide motor or in its wiring.
E86 Slide motor Motor current shows break F4 1 Break or loose contact in slide motor or in its wiring.
E87 Exhaust air slide valve Path of slide valve restricted (motor current error during slide valve test) F4 1 Exhaust slide valve stuck with grease deposits.
2 Motor or slide valve jammed (mechanical defect).
3 Short circuit in slide motor or in its wiring.
E88 Exhaust air slide valve Path of slide valve restricted during normal operation (motor current shows current reduction) 1 Exhaust slide valve stuck with grease deposits.
2 Motor or slide valve jammed (mechanical defect).

2 Malfunctions and messages without error code

Message Description Possible cause 1)
H1 Insert water tank 1 Water tank is missing.
2 Water tank not in end position or faulty.
3 Mechanical lock of water valve damaged or missing.
4 Switch holder broken off or warped.
5 Break in switch contact or in its wiring.
H2 Fill water tank Pour away descaler, add 1.2l water / Pour away water, add 1.2l water 1 No water in tank.
2 Water tank not inserted correctly.
3 Water inlet blocked or scaled up.
4 Inlet valve jammed or faulty. Hose is squashed.
5 Faulty level detector pin wiring.
6 Break in earth conductor of heating element of boiler or in processor.
H3 Close appliance door 1 Door is open.
2 Magnet in door is not in correct position or has come away.
3 Reed switch or its holder not mounted correctly.
4 Door will not close properly too (e.g. because of faulty door seal).
5 Break in door contact or in its wiring.
H4 2) Insert food probe 1 Food probe is not plugged in.
2 Loose contact in food probe socket.
3 Wiring of food probe socket is faulty.
H5 Add 0.5l descaler and press OK 1 Start not confirmed by pressing OK button.
H6 2) Soft roasting interrupted 1 Soft roasting interrupted with OFF button. Press OK button to continue or OFF button to abort.
2 Control unit faulty.
H10 Boiler scaled up, please descale! 1 Boiler scaled up (reached max. number of operating hours for boiler).
2 Problems in the water system (see also E66, E68, E70 and E72 error codes).
H11 Appliance blocked, descaling necessary 1 Descale run error (see error codes E74 to E76).
CAPr Add 0.5l descaler and press OK 1 Start not confirmed by pressing OK button.
CA 1 Descale running 1 Descale in descaling phase.
CA 2 Descale 1st rinsing cycle 1 Descale in 1st rinsing cycle.
CA 3 Descale 2nd rinsing cycle 1 Descale in 2nd rinsing cycle.
CA - Descale repeat 1 rinsing cycle 1 Descale in 2nd rinsing cycle.
End Pour away water, descaling completed 1 Remove water tank and empty water
dEn0 *** Demo-Modus *** 1 Demo-Modus (mode used for demonstration purposes) is on.
dIAG Diagnostic mode 1 Diagnostic mode is on.

3 Malfunctions without fault display

Malfunction Possible cause 1)
Heating element(s) not heating up. 1 Heating element(s) or the corresponding wiring is faulty.
From time to time, control unit with a strange display. 1 Moisture in control unit due to steam penetrating panel area.
2 Loose or faulty plug and socket connection or ribbon cable.
Water being pumped back even though water tank not in place 1 Water tank detection switch caught on housing.
Heavily build-up of condensate laterally externally or in condensate conduit 1 Door not closed firmly enough.
2 Door seal fitted incorrectly or damaged.
3 Door hinge faulty or damaged. Check closing force.
Liquid drips down from the bottom of the appliance. 1 Condensate conduit overflow. See malfunction "Heavily build-up of condensate laterally externally or in condensate conduit".
2 Door is left open after cooking process at an opening angle outside the lock position (approximately 16° / 86°). Mount diffuser foil K4.0218.
Drain pump and evt. cool air fan run periodical in the standby mode for aproximately 30s. (for example every 90min) Malfunction occurs just if water tank is inserted and filled! 1 Valve of the water tank has a small leak
2 Rubber grommet of the water valve is not correctly mounted
3 Water valve is blocking

4 Turning the Demo-Modus on / off

Requirement: In order to turn the Demo-Modus on / off, the appliance must be ready for operation, i.e. all displays - with the exception of the time display – should be dark.

To turn on: Hold the "Illumination" + "OK" + "Off" buttons depressed for 10 seconds. "dEn0" (demo off) appears in the display.
Press the "OK" button and using the adjusting knob set the flashing display to "dEn1" (demo on).
Press the "OK" button to confirm the change in setting. Press the "Off" button to exit the configuration mode.

To turn off: Press the "Illumination" + "OK" + "Off" buttons simultaneously. "dEn1" (demo on) appears in the display.
Press the "OK" button and using the adjusting knob set the flashing display to "dEn0" (demo off).
Press the "OK" button to confirm the change in setting. Press the "Off" button to exit the configuration mode.

5 Diagnostic mode

Requirement: In order to turn the diagnostic mode on / off, the appliance must be in the OFF mode (all displays - with the exception of the time display - should be dark) or in the error mode (error message is displayed).

To turn on: Hold the "Illumination" + "OK" buttons depressed for 10 seconds.
"diAG" appears in the display.
Press the "OK" button to confirm selection of the diagnostic mode.
"HiSt" appears in the display.
Press the "Off" button. Alternatively, the diagnostic mode turns off automatically after 1 hour.

Menu: Use the adjusting knob and the "OK" button to navigate the menu.

Menu structure:

Menu level 1 Menu level 2 1) Description
Hist H--- No history entries.
Hixx / E yy XX: Number of history entry, whereby 1 corresponds to the latest entry.
yy: Error code of malfunction that has occurred.
ECnt E--- All error counters show zero.
E XX / yyy XX: Error code
yy: Number of errors
yyy: Number of times descaling performed
Clr Clr0 Do not clear error history / counters.
Clr1 Clear error history / counters.
Cnt Cnt1 / xxxx Cnt1: Total operating hours
xxxx: Number of hours (rounded)
Cnt2 / XXXX Cnt2: Hardware resets
xxxx: Number of resets
Cnt3 / XXXX Cnt3: Descale
xxxx: Number of times descaling performed

PDF preview unavailable. Download the PDF instead.

K4.20676D-BB Microsoft Office Word 2007 Microsoft Office Word 2007

Related Documents

Preview V-ZUG Induction Hob Error Codes, Troubleshooting, and FAQs
Comprehensive guide to V-ZUG induction hob error messages (GK11TI(X)FKZ, CTI6T-31132, CTI6T-31134), including causes, solutions, FAQs, and performance troubleshooting.
Preview V-ZUG CookTop V6000 1906 FullFlex Induction Hob - Operation Manual
Comprehensive operation manual for the V-ZUG CookTop V6000 1906 FullFlex induction hob, covering safety instructions, device description, operation, maintenance, troubleshooting, and V-ZUG-Home connectivity.
Preview V-ZUG Warming Drawer Operating Instructions: WS60144, WS60162, WS60220, WS60283, WS60312
Comprehensive operating instructions for V-ZUG warming drawers, including safety precautions, usage guides, care instructions, troubleshooting, and technical data for models WS60144, WS60162, WS60220, WS60283, and WS60312.
Preview V-ZUG Group 2020 Annual Report: Financials, Strategy, and Sustainability
V-ZUG Group's 2020 Annual Report details financial performance, strategic initiatives, and segment results for Household Appliances and Real Estate. Highlights include the company's spin-off, stock exchange listing, sustainability efforts, and commitment to innovation.
Preview V-ZUG Combair V600 Oven: Operating Instructions and User Guide
Detailed operating instructions for the V-ZUG Combair V600 oven. Covers safety precautions, appliance description, operating modes, function buttons, V-ZUG-Home connectivity, user settings, care and maintenance, troubleshooting, accessories, technical data, and tips for optimal use.
Preview V-ZUG GK11TIFK Induction Hob Operating Instructions
Comprehensive operating instructions for the V-ZUG GK11TIFK induction hob, covering safety, operation, user settings, maintenance, troubleshooting, and technical data. Learn how to use your V-ZUG induction hob efficiently and safely.
Preview V-ZUG Steamer V4000 Operating Instructions
Comprehensive operating instructions for the V-ZUG Steamer V4000. Learn about installation, user settings, applications, care, maintenance, and troubleshooting for your V-ZUG appliance.
Preview V-ZUG CookTopInduction V6000 FullFlex Induction Hob Operating Instructions
Comprehensive operating instructions for the V-ZUG CookTopInduction V6000 FullFlex induction hob, covering safety, usage, settings, maintenance, and troubleshooting.