User Manual for MICROTECH models including: 144303271, 144310271, 144303281, 144310281, 144303371, 144306371, 144306372, 144310371, 144310372, 144310373, 144303271 Computerized Double Column Height Gauge, 144303271, Computerized Double Column Height Gauge, Double Column Height Gauge, Column Height Gauge, Height Gauge, Gauge
Touchprobe micron tablet height gauge - MICROTECH
File Info : application/pdf, 12 Pages, 3.04MB
DocumentDocumentMICROTECH PROBE MODE 2D MODE COMPUTERIZED DOUBLE COLUMN HEIGHT GAUGE USER MANUAL ISO17025:2017 ISO 9001:2015 www.microtech.ua MICROTECH SPECIFICATION MANUAL MICRON HEIGHT GAUGE 2D connection Measuring HUB Graphic Analog scale Preset Go/NoGo Max/Min Formula Timer Temp comp Linear corr Calibr date Recharge Memory WIRELESS USB Item No Range Resolut. Accuracy mm mm m 144303271 0-300 ±15 · · · · · · · · · · · · · · · · 144306271 0-600 0,001 ±20 · · · · · · · · · · · · · · · · 144310271 0-1000 ±30 · · · · · · · · · · · · · · · · TOUCHPROBE MICRON HEIGHT GAUGE Touch Probe 2D connection Measuring HUB Graphic Analog scale Preset Go/NoGo Max/Min Formula Timer Temp comp Linear corr Calibr date Memory WIRELESS USB Range Resolut. Accur. Item No mm mm m 144303281 20-320 ±10 · · · · · · · · · · · · · · · · 144306281 20-620 0,001 ±15 · · · · · · · · · · · · · · · · 144310281 20-1020 ±20 · · · · · · · · · · · · · · · · MANUAL 2D HEIGHT GAUGE 2D connection Measuring HUB Graphic Analog scale Preset Go/NoGo Max/Min Formula Timer Memory WIRELESS USB Folders / 2000 val Long range / HID USB HID / Update Item No Range ZX Resolut. Accu- racy Z X mm mm mm mm m 144303371 0-300 144306371 144306372 0-600 144310371 0-25 0-50 0-25 0,001 0,0001 ±15 · · · · · · · · · ±20 · · ··· · · · · · · ··· · · · · · · ··· · · · · 144310372 0-1000 0-50 ±30 · · · · · · · · · 144310373 0-100 · · ··· · · · · TECHNICAL DATA Parameters LED display Indication system Power supply Charging port Case material Wireless data transfer USB data transfer color 3,5 inch 480x320 MICS 4.0 Rechargeable Li-Pol battery 2000 mAh micro-USB Aluminium Long range / HID USB HID MAIN INFO MICROTECH BUILT-IN BATTERY - rechargeable Li-Pol battery SWITCH ON DEVICE - button push (1 sec) SWITCH OFF DEVICE - button push (3 sec)/ auto switch off DATA TRANSFER - programming throw menu DOWNLOAD APP DOWNLOAD MDS APP FOR MICROTECH DEVICES WIRELESS CONNECTION FROM www.microtech.ua, GooglePlay & App Store MICROTECH DATA TRANSFER 3 MODES OF DATA TRANSFER (USB + 2 WIRELESS MODES) WIRELESS CONNECTION TO MDS APP WIRELESS data transfer to MICROTECH MDS app for Windows, Android, iOS SAVING DATA TO XLS. CSV FORMATS TRANSFER DATA TO CAD, SPC OR OTHER SOFTWARE FREE SOFTWARE NO DONGLE TRANSFER DATA TO EXCEL OR OTHER TABLE EDITORS SAVING GRAPH WIRELESS HID CONNECTION USB HID CONNECTION NO DONGLE WIRELESS HID and USB HID data transfer (like keyboard) direct to any customers app and system 7 WAYS HOW TO TRANSFER DATA TO PC OR TABLET TRANSFER DATA TO CAD, SPC OR OTHER SOFTWARE TRANSFER DATA TO EXCEL OR OTHER TABLE EDITORS TRANSFER DATA TO ANY BROWSWE OR APP TOUCHSCREEN TAP BUTTON PUSH SELECTED FORCE BY TIMER FROM MEMORY IN MDS APP FROM PAIRED DEVICE MAIN SCREEN EXTERNAL MODE (for TOUCHPROBE modification) INTERNAL MODE (for TOUCHPROBE modification) HUB MODE ACTIVATING MICROTECH WIRELESS CONNECTION STATUS AND SETTINGS WIRELESS DISCONNECTED WIRELESS CONNECTED WIRELESS HID CONNECTED USB CONNECTION STATUS AND SETTINGS USB HID DISCONNECTED USB HID CONNECTED DIRECTION INDICATION TOUCH-PROBE SETTINGS ON-LINE GRAPHIC MODE STANDARD or FOLDER system can MEMORY be activated throw MEMORY menu For save measuring data to internal device memory touch data area on screen or button push. You can view saved data or send by WIRELESS or USB connection to Windows PC, Android or iOS It's possible to use Standard or Folders memory modes FOLDERS SYSTEM MEMORY 2000 VAL. MEMORY EXPORT STATISTIC MICROTECH ANALOG SCALE FOR PROBE MODE ON-LINE GRAPHIC MODE MAIN SCREEN on 2D mode 2D AND HUB MODE PROBE -Saving data when Probe will reach value PROBE Auto - Saving data when Probe will reach value with this value compensation 2D - 2 axis data reading 2D Sync- Synchronized 2 axis data reading MENU DISPLAY NAVIGATION IN MENU BY TOUCHSCREEN EXIT FROM FUNCTION - TOUCHSCREEN SWAP or BUTTON PUSH (1s) FUNCTIONS MICROTECH LIMITS mode GO/NOGO COLOR INDICATION LIMITS ON MAIN SCREEN Go NoGo MAX - NoGo more Upper limit Upper limit MIN - NoGo less Lower limit RANGE - Go between Limits NONE - Analog scale active Lower limit Yellow zone on analog scale PEAK mode MAX/MIN DISABLE- non active mode ENABLE - activating mode REFRESH - refresh peal value according timer INDICATION AND SAVING MAX OR MIN VALUES MAX - indicating MAX measured value MIN - indicating MIN measured value RANGE - indicating difference between MIN & MAX value TIMER mode SAVING DATA TO MEMORY OR SENDING WIRELESS/USB BY TIMER Select timer period Reset to disactivate mode FORMULA mode RESOLUTION selection Select FORMULA Type (Math, Radius or other) Select arguments Resolution selecting mm/inch conversion DISPLAY settings Sleep OFF (15 s low brightness off, sleep off) Sleep 15s (15 s low brightness on, sleep off) Sleep ON (15 s low brightness on, sleep on) Display rotation 0°, 90°, 180°, 270° Brightness level MICROTECH LINEAR error compensation Re-calculation detail size to calibration conditions (20°C) TEMP compensation Manual Temperature setting FUNCTIONS Linear correction error's on device actual values correct values by up&down button confirm point correction 4 types of material for selection: - Glass, Quartz - Stainless steel - Cuprum and alloys - Alluminium and alloys LINK to app's QR Link to MICROTECH web site page with MDS Software download - Android, iOS, Windows versions - Free and Pro versions - Manuals RESET to Factory settings EXTRA CALIBRATION date info Push 10 times to RESET device to factory settings Push 10 times to FIRMWARE UPDATE Selecting normal or inverted axis mode (+/- value indication) oefficient setting (for distributor and calibration only) Device INFO Push for change calibration date info Information about device - Firmware version - MAC adress for WIRELESS connection MEMORY MICROTECH STANDARD or FOLDER system can be activated throw MEMORY menu Values in each Folder STANDARD MODE FOLDERS MODE MICROTECH DATA TRANSFER MODES ACTIVATE REQUESTED DATA TRANSFER MODE FROM MAIN SCREEN WIRELESS CONNECTION STATUS AND SETTINGS WIRELESS DISCONNECTED WIRELESS CONNECTED WIRELESS HID CONNECTED USB CONNECTION STATUS AND SETTINGS USB HID DISCONNECTED USB HID CONNECTED WIRELESS data transfer Recconection button Wireless power regulation ON - WIRELESS data transfer to MDS App for Android, iOS, Windows HID- WIRELESS HID direct transfer data to any App in Windows, MacOS, Linux, Android devices (like keyboard). Configure data format in USB sub-menu 2D-S - Slave device on WIRELESS connection on HUB mode 2D-M - Master device on WIRELESS connection on HUB mode USB OTG data transfer Connect USB cable to PC & Activate USB HID connection mode Select setting of data transfer Direct transfer data to any App in Windows, MacOS, Linux, Android devices Configurating data transfer Dot/Comma and Tab/Arrow Down/CR+LF HUB MODE ACTIVATING MICROTECH A.C.on - Auto Connection active A.C.off - Auto Connection no active 2D MODE External Wireless device conneciton PROBE -Saving data when Probe will reach value PROBE Auto - Saving data when Probe will reach value with this value compensation 2D - 2 axis data reading 2D Sync- Synchronized 2 axis data reading Disable - switch off modes Symbol between Axis Graphic mode indication setting 2D CONNECTION PROCESS 1. Slave device WIRELESS menu- 1.1 Push CLEAR button and 1.2 Activate 2D Slave mode 2D-S 2. MASTER device WIRELESS menu- 2.1 Push CLEAR button and 2.2 Activate 2D Master mode 2D-M 3. MASTER device HUB connection menu- 3.1 Activate 2D or 2D Sync mode and 3.2 Setting A.C.on /off (auto-reconnect) and 3.3 setting of saving on memory and transfer data (X, Y or XY syncronized) 4. MASTER device HUB connection menu- 4.1 Push CONNECT button and start searching Slave devices (40s) 4.2 push for MAC adress of indicated slave deivce to start connection. 4.3. If MASTER device indicate SUCCESFULL CONNECTION - you can start measurings, but If MASTER device indicate CONNECTION ERROR - re-connect devices again (from step 1). A.C.on - Auto Connection active A.C.off - Auto Connection no active PROBE -Saving data when Probe will reach value PROBE Auto - Saving data when Probe will reach value with this value compensation 2D - 2 axis data reading 2D Sync- Synchronized 2 axis data reading Disable - switch off modes PROBE MODE External Wireless device conneciton Axis priority selecting Setting PROBE limit value 2D CONNECTION PROCESS 1. Slave device WIRELESS menu- 1.1 Push CLEAR button and 1.2 Activate 2D Slave mode 2D-S 2. MASTER device WIRELESS menu- 2.1 Push CLEAR button and 2.2 Activate 2D Master mode 2D-M 3. MASTER device HUB connection menu- 3.1 Activate PROBE or PROBE Auto mode and 3.2 Setting A.C.on / off (auto-reconnect) and 3.3 Axis priority and 3.4 Probe limit value 4. MASTER device HUB connection menu- 4.1 Push CONNECT button and start searching Slave devices (40s) 4.2 push for MAC adress of indicated slave deivce to start connection. 4.3. If MASTER device indicate SUCCESFULL CONNECTION - you can start measurings, but If MASTER device indicate CONNECTION ERROR - re-connect devices again (from step 1). VIDEO INSTRUCTION of 2D and PROBE MODE CONNECTION MICROTECH INDUSTRY 4.0 INSTRUMENTS 0,1m 1m FORCE CONTROL 1-20N 0,1m 0,1m MICROTECH innovative measuring instruments 61001, Kharkiv, Ukraine, str. Rustaveli, 39 tel.: +38 (057) 739-03-50 www.microtech.ua tool@microtech.ua 1m Change without prior notice