Tuncmatik Lift 1500 / 2000VA Uninterruptible Power Supply (UPS) User Manual

Front Panel

The front panel of the UPS features the following indicators and controls:

The front panel also displays the Tuncmatik logo and a power symbol for the On/Off button.

Back Panel

The back panel of the UPS includes the following connections and protection:

Product Description

This UPS is specifically designed for lifts, offering a lightweight and compact design suitable for limited working environments. It features boost and buck AVR (Automatic Voltage Regulation) to stabilize input voltage and includes a DC Start function, allowing the UPS to be started without AC power.

Main Features:

Inspection

Upon receiving the UPS, remove it from its packaging and inspect for any shipping damage. If damage is found, repack the unit and return it to the place of purchase.

Charging

The internal battery is shipped fully charged but may lose some charge during transit. To ensure optimal performance, recharge the battery before use. Turn on the UPS, plug it into a suitable power supply, and allow it to charge for at least 6 hours. The green LED will flash while the UPS is charging.

Placement

Install the UPS in a protected environment with adequate airflow, free from excessive dust, corrosive fumes, and conductive contaminants. Avoid operating the UPS in environments with high ambient temperature or humidity. The following conditions should be avoided: direct sunlight ☀️, rain ?️, and extreme temperatures ?️.

Turn On/Off

DC Start (Cold Start)

All series are equipped with DC Start. To start the UPS when AC utility power is not available, press the power button for a minimum of 1 second.

Technical Specifications

1500VA / 900W 2000VA / 1200W
INPUT
Voltage 220 / 230 / 240 VAC
Voltage range 162-265 VAC
OUTPUT
Voltage range ± 10 %
Transfer time 2-6 ms, 10 ms max
Waveform Simulated sine wave
BATTERY
Type & Number 2 x 12V 9Ah
Charging time 4-6 hours to recover 90% capacity
DIMENSIONS AND WEIGHT
Dimensions D x W x H (mm) 300 x 180 x 190 300 x 213 x 190
Net weight (kg) 12.0 13.3
ENVIRONMENT
Humidity 0-40°C, 0-90% (non-condensing)
Noise level < 40 dB

Troubleshooting

Use the table below to solve minor problems:

Symptom Possible Cause Remedy
No LED display on the front panel. 1. Battery weak.
2. Battery defect.
1. Charge battery up to 8 hours.
2. Replace with the same type of battery.
Alarm buzzer beeps continuously when AC supply is normal. Overload of the UPS. Verify that the load matches the UPS capability specified in the specs.
When power failure, back-up time is shorten. 1. Overload of the UPS.
2. Battery voltage is too low.
3. Battery defect due to high temperature operation environment, or improper operation to battery.
1. Remove some non-critical load.
2. Charge battery 8 hours or more.
3. Replace with the same type of battery.
Mains normal but Yellow LED is flashing. Power cord is loose. Check the power cord.

If any abnormal situations occur that are not listed above, please contact service personnel immediately.

Safety Warnings

This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user-serviceable parts. Only technical service personnel may perform repairs.

Models: 1500VA Uninterruptible Power Supply UPS, 1500VA, Uninterruptible Power Supply UPS, Power Supply UPS, Supply UPS, UPS
KGK - Lift 1500-2000VA - User Manuel-1 Acrobat Distiller 22.0 (Windows)

Related Documents

Preview Tuncmatik PowerUP ECO X9 6kVA / 10kVA Online UPS User Manual
Comprehensive user manual for Tuncmatik PowerUP ECO X9 6kVA and 10kVA Online UPS systems, covering installation, operation, safety, troubleshooting, and specifications.
Preview Tuncmatik PowerUP ECO X9 6kVA/10kVA Online UPS User Manual
Comprehensive user manual for the Tuncmatik PowerUP ECO X9 series of 6kVA and 10kVA online UPS systems, covering installation, operation, maintenance, and specifications.