Thanks for choosing the AQUAPHOR H20-c. To use and maintain this product correctly, please read the manual carefully before using. Keep the manual properly.
- This is a vertical water dispenser. Please place it on the ground firmly to avoid falling.
- Operation conditions:
- Water source: municipal tap water
- Feed water pressure: 0.1 MPa ~ 0.4MPa
- Feed water temperature: 5-38°C
- Altitude: <1500 meter
- Check the product from time to time to see if there is any leakage on the connections or any creepage on the wires. If the product fails, please cut off the water and power supply immediately, and contact your dealer.
- If this product will not be used for a long time, cut off water and power supply. If it has not been used for more than 3 days, drain off all the remaining water in tanks and flush the system for more than 5 minutes before putting it into use again.
- This product is strictly forbidden to be operated by children and is designed for indoor use only. Do not use it in an explosive environment.
- Every machine will be going through a water leakage test before packing. It is normal to have residual water stains.
- Installation and maintenance should be performed by a professional. It is necessary to follow this instruction manual strictly; otherwise, AQUAPHOR will not be responsible for any failure or consequence.
2. PRODUCT FEATURE INTRODUCTION
Product Introduction
Water Dispenser with hot, cold, and ambient water. Recommended installation places: office, club, hotel, airport, train station, etc.
Product Dimension
321*393*1164 mm
Water treatment process: Feed water → Pro1 → Pro 100 → Pro M → Output water
3. PACKING LIST
Name | Quantity | Name | Quantity |
---|---|---|---|
Main Body | 1 set | Additional cartridge for leak protection valve | 1 pc. |
Pro 1 | 1 pc. | Tube 1/4", 4 m | 1 pc. |
Pro 100 (RO Membrane) | 1 pc. | Flush plug | 1 pc. |
Pro M | 1 pc. | Drain clamp | 1 set |
Connecting node | 1 pc. | Instruction manual | 1 pc. |
4. TECHNICAL PARAMETERS
Model Type | H20-C (5L Pure water tank / 1.8L hot tank / 3L cold tank) |
Inlet water pressure | 0.1 MPa~0.4 MPa |
Inlet water temperature | 5-38 °C |
Voltage and frequency | 220V, 50Hz / 110V, 60Hz |
Rated power | 650W |
Heating power | 500W |
Cooling power | 100W |
Purified water flow | 15.6 L/Hour |
Hot water temperature | 88-93 °C |
Hot water tank capacity | 1.8 L |
Cold water temperature | 5-10 °C |
Cold water tank capacity | 3 L |
Ambient water tank capacity | 5 L |
Noise level | 59 dB |
Dimensions (LWH) | 321 x 393 x 1164 mm |
Net weight | 22.2 kg |
Gross weight | 24.5 kg |
5. ELECTRIC SCHEMATIC DIAGRAM
The diagram shows the electrical connections for the water dispenser, including the main control panel, adaptor, fuse, and various components like the hot tank, compressor, switches, and display.
Components connected to the Main Control Panel: Hot Tank, Compressor for cooling, Hot Tank NTC, Cold Tank NTC, Low Pressure Switch, Booster Pump, Inlet Water Solenoid Valve, Drain Water Solenoid Valve, Ambient Water Solenoid Valve, Cold Water Solenoid Valve, Hot Water Solenoid Valve, High & low Liquid Level Switch, Heating Switch, Cold Switch.
Display connections: Display, Child Lock, Hot Water, Ambient Water, Cold Water.
6. STRUCTURE INSTRUCTION
The diagram illustrates the physical structure of the water dispenser, showing the upper unit containing the water tanks and dispensing area, and the lower unit housing the filtration and cooling/heating components. Key connection points for water inlet, drain, and power are also indicated.
Water connections shown: Drain of Hot Water Tank, Water Inlet, Drain of Cold Water Tank, RO Drain, Drain of Water Pan.
7. INSTALLATION PROCEDURES
Tools Required:
- Cross screw driver
- Adjustable wrench
- Scissors
Please check if the accessories are complete as per the packing list.
Installation position required:
- Close to a 220V/110V socket.
- Close to a municipal tap water source.
- Close to a drain outlet. Please note that the position of drain pipes should be at least 20 cm lower than the water pan.
Install the connection node:
- Insert the pre-moistened end of the tube of the water filter (1) into the plastic sleeve of the connecting node (2) until it stops about 15 mm deep and house the clip (4).
- Check the tightness of the tube (1) fastening: with a force of 80–100 N, the tube should not be pulled out.
- Wrap threads of the connection node with Teflon tape.
Install the drain clamp:
- Remove the protective film from the gasket. Bond the gasket to the inside of the clamp so that the hole in the gasket matches the hole in the clamp fitting.
- Place the clamp on the pipe and then tighten the bolts. The bolts should be tightened evenly so that the two pieces of the clamp are parallel.
- Drill a 7 mm hole through the clamp connection. Put a plastic nut on the free end of the drain tube and, inserting the tube into the drain clamp by 20–30 mm, screw the nut onto the fitting.
Connect the silicon tube to the drain of the water pan or a bucket.
ATTENTION! The end of the pipeline must be flat where the connecting node is connected. Do not use excessive force when tightening the clamping nut. Otherwise, it will damage the gasket.
In the event of any mechanical damage to the connecting node due to improper installation and use, claims will not be accepted.
- Shut off the cold water line and relieve excess pressure.
- Make sure that there is a sealing gasket (3) in the clamping nut of the connecting node (2).
- Connect the connecting node (2) to the pipeline. If necessary, use thread seal tape to seal the external thread of the node.
- Close the inlet cock of the connecting node and supply water from the cold water supply line to make sure that the connection is tight (no leaks).
- Pull the retaining clip (4) out from under the plastic sleeve of the connecting node (2).
Take off the front panel and install filter cartridges to water purifier according to the labels indicated below.
Diagrams show the AQUAPHOR OSMO PRO, AQUAPHOR PRO 1, AQUAPHOR PRO 100, and AQUAPHOR PRO M filter cartridges.
Please pay attention to the positions of filter cartridges and install them in the right order (see Fig. 6).
8. HOW TO INSTALL
Install the drain pipe:
Firstly, cut two pieces of PE pipes in suitable length and make sure the notches are flat and smooth. Then, connect the outlet of RO drain water and Water Pan to the PVC downcomer.
Diagram shows the water dispenser with dimensions and connections for Power Cord, Inlet water, Drain of Water Pan, and Drain Water to a PVC Downcomer.
Install the filter cartridge:
- Take off the front panel of the dispenser.
- Insert the filter cartridge into the cap and then twist the body of the cartridge clockwise until it matches the right position.
Replace the filter cartridge:
- Take off the front panel of the dispenser.
- Twist the filter cartridge anticlockwise to disassemble it and then install a new one as above.
Diagrams show the process of installing and replacing filter cartridges.
9. HOW TO USE
Service Life of Filter Cartridges and Filter change Reminder
Cartridge | Cartridge lifetime | Indicator light status |
---|---|---|
PRO 1 cartridge (K1 on display) | Full life: 150 hours | 150-100 hours display 3 grids, 100-50 hours display 2 grids, 50-0 display 1 grid |
Remaining life > 0 | All filter bars flash | |
PRO 100 membrane (RO on display) | Full life: 600 hours | 600-400 hours display 3 grids, 400-200 display 2 grids, 200-0 display 1 grid |
Remaining life > 0 | All filter bars flash | |
PRO M cartridge (K7 on display) | Full life: 300 hours | 300-200 hours display 3 grids, 200-100 display 2 grids, 100-0 display 1 grid |
Remaining life > 0 | All filter bars flash |
Each light indicator will flash when its corresponding filter cartridge's lifetime is run out.
10. SPECIFICATION OF ELECTRONIC PARTS
1. UI
1.1. Product work UI interface
The interface displays icons for water shortage, water production, temperature settings, filter status (K1, RO, K7), and lock status. It also shows temperature in Celsius and a percentage for filter life.
Icons and their functions:
- Water shortage indicator light
- Water production indicator light (3 temperature models)
- Setting button (2 temperature models)
- Cold water button (3 temperature models)
- Ambient water button
- Heating indicator light
- Cooling indicator light (3 temperature models)
- K7 filter indicator light
- Unlock button
- Hot water button
- RO filter indicator light
- K1 filter indicator light
1.2. Display size
Diagram shows the dimensions and layout of the display panel.
2. Waterway schematic
Diagram illustrates the H20 reverse osmosis series process, showing the flow of water through various components including tanks, valves, filters (K1, RO, K7), booster pump, and outlets for hot, cold, ambient, and wastewater.
3. Key Icons and Functions
No. | Icon name | Icon | Icon color | Function Description |
---|---|---|---|---|
1 | Cold water outlet button | * | White | Touch to get cold water, and then touch to stop cold water. After opening, if no one operates, the water will automatically stop in 1 minute. |
2 | Ambient water outlet button | ? | White | Touch to get ambient water, and then touch to stop the water. After opening, if no one operates, the water will automatically stop in 1 minute. |
3 | Filter display | K1 RO K7 |
White | They are K1 (Pro 1), RO (Pro 100), and K7 (Pro M) respectively. Each grid represents 1/3 of the life. When the life is less than 1/3, one grid will be off. When the life is complete, the letters corresponding to the filter cartridge will flash to alarm. |
4 | Water temperature display, child lock | 188 °C ? | White | Touch the "Cold water" key to display the cold water temperature, touch the "Hot water" key to display the hot water temperature. Touch the "Ambient water" key; it does not display the temperature. |
5 | Water production, water shortage, heating, cooling | ☀️ ? ♨️ ❄️ | White | The "Water Making" icon lights up, indicating that the machine is in the working state of the pump (if it is a reverse osmosis system, the pump refers to the booster pump); extinguished, indicating that water production has stopped. "Lack of water" indicates that the machine is short of water and the water tank is at a low position. The "Heating" light comes on and the machine starts to heat up. The "Cooling" light is on, and cooling begins. When it is finished, the corresponding light goes out. |
6 | Hot water, child lock key | ♨️ ? | White | Unlock and click the hot water button, the hot water will come out. After opening, if no one operates, the water will automatically stop in 1 minute, and it will be automatically locked at the same time. If it is unlocked, there is no operation after that, 10S will automatically lock. |
Remark: This machine can provide three temperatures of water. If one of them is in the water, pressing any other button will not affect the current water. If you want to choose another temperature of water, just turn off the current water and re-select another temperature, then it can water normally.
4.1 Refrigeration switch
Controls whether the machine allows the cooling function to be enabled.
- The switch is closed: Press from the "O" state to the "-" state to turn off the refrigeration function of the machine.
- The switch off: Press from the "-" state to the "O" state to turn on the refrigeration function of the machine.
Diagram shows the location of the refrigeration and heating switches on the back of the machine, along with button labels.
4.2 Heating switch
Controls whether the machine allows the heating function to be enabled.
- The switch is closed: Press from the "O" state to the "-" state to turn off the heating function of the machine.
- The switch off: Press from the "-" state to the "O" state to turn on the heating function of the machine.
5. Function description
5.1. Fault Display the corresponding fault code:
- 02 indicates that the NTC probe is faulty, short-circuited, or disconnected.
- 03 Water shortage fault: when the water level (low water level or high water level) is still not detected after 60 minutes of water production, this code appears.
- 04 When the low pressure switch is faulty, when the low pressure switch is disconnected for 1S, it means that the raw water is short of water, the water pressure is insufficient, or the low pressure switch is faulty, and this code appears.
When there is a fault, the fault indicator will flash continuously, and it will be accompanied by the sound of the buzzer.
5.2. Power-off memory function:
The electric control board has a power-off memory function.
5.3. Power-saving mode function:
The machine automatically enters power-saving mode without taking water for 100 seconds, and the display screen is slightly bright. Press any key to restore the system to normal working state.
5.4. Filter life reset:
Press the set key: long press * 0 for 3S at the same time. When the "heating" icon starts flashing, touch 0 (the touch sequence of continuous output water is "heating" – "cooling" – K1 – RO – K7), then select the related filter cartridge to reset. Long press * for 3S, then the filter cartridge is finished reset. After all settings are completed, long press * 0 for 3S to complete the setting.
5.5. The temperature setting (only for hot water and cold water):
Long press * 0 for 3S at the same time. When the "heating" icon starts flashing, touch ◊ (the touch sequence of continuous output water is "heating" – "cooling" – K1 – RO – K7). When "heating" flashes, touch ♨️ to raise the temperature, and touch ❄️ to lower the temperature. The hot water temperature ranges from 50 °C to 93 °C. After the hot water temperature is set to the desired temperature, touch 0. Making cold water: After "Cooling" starts blinking, the temperature setting procedure is the same as that for hot water. The range of cold water temperature is 3 °C to 15 °C. After all settings are completed, long press * 0 for 3S to complete the setting. If you don't press any key, it will exit automatically 10S later.
5.6. Version display:
Press * & for 3S in normal state to enter the version display. The current version number is 101.
5.7. Check the hot water temperature:
When ? is not unlocked, touching ♨️ will display the hot water temperature, and when the button is released, the hot water temperature disappears.
6. Simple program description
6.1. Safety inspection when plugged in and powered on:
The buzzer of the machine will sound once after the power is turned on. If the water level of the water tank cannot detect the low water level, the heating and cooling functions of the machine's hot tank and cold tank will not be activated. At this time, the pump starts to work and rinses for 30 seconds and then starts to produce water. When the water level detects the bottom water level, the hot tank and the compressor start to work (the fan works with the compressor), and when the water is produced until the high water level, the pump (booster pump or water pump) stops working to produce water.
6.2. When the machine is working normally, the logic of water production:
When the machine is in the water outlet state, it starts water production when the water level of the water tank reaches the low water level, and stops water production when it reaches the high water level. When the machine is in the state of no water, when the water is in the middle of the high water level and the low water level, when the high water level is not detected for 30 seconds, the machine starts to make water until the high water level is reached. When the water level (low water level or high water level) is not detected after 60 minutes of water production, this code 03 water shortage alarm will appear.
6.3. Hot water temperature compensation:
When the temperature is between 51°C and 74 °C, add 4 °C to the displayed temperature, and when the temperature is 74 °C to 90 °C, add 9 °C to the displayed temperature, and when the temperature is greater than 90 °C, display 100 °C. When the temperature is ≤51 °C, it displays the real-time temperature.
6.4. Heating and cooling logic.
6.4.1. Heating logic.
The factory program of the water dispenser sets the default temperature to 93 °C. When the temperature reaches 94 °C, the water dispenser stops heating. When the temperature drops to a temperature difference of 5 °C from the set temperature, it starts to heat.
6.4.2. Refrigeration logic
The factory default setting temperature of the water dispenser is 3 °C. When the sensor detects the set temperature, the compressor stops working. When the temperature rises to 6 °C, the compressor starts to work.
7. UV lamp function
Turn on forcibly for 1 hour, and then turn on for 20 minutes every 40 minutes for sterilization.