Instruction Manual for JBC models including: B IRON 115T, Nano Tweezers B iRON Station, B IRON 115T Nano Tweezers B iRON Station
B·IRON 115T - High-Precision Tweezers Station
B·IRON115T - High-Precision Battery Rework System
File Info : application/pdf, 20 Pages, 32.67MB
DocumentDocumentINSTRUCTION MANUAL B·IRON 115T Nano Tweezers B·iRON Station This manual corresponds to the following references: Console included*: BI115TUA 120 V - N. America, Taiwan BI115TIA 230 V - India BI115TA 230 V - Europe BI115TKA 230 V - United Kingdom BI115THA 230 V - China BI115TJA 100 V - Japan Console not included*: BI115TUQA 120 V - N. America, Taiwan BI115TIQA 230 V - India BI115TQA 230 V - Europe BI115TKQA 230 V - United Kingdom BI115THQA 230 V - China BI115TJQA 100 V - Japan Packing List The following items are included: Stand for B 115T Nano B·iRON Tweezers ......... 1 unit Ref. B210-SA B 115T Nano B·iRON Tweezers ........................ 1 unit Ref. B210-A B·iRON Console 7"...... 1 unit* *included according purchased reference Cable USB ....................... 1 unit Ref. 0028092 Brass Wool ..................... 1 unit Ref. CL0300 already assembled in the stand Manual .............................. 1 unit Ref. 0028298 Power Cord ........................................................................................................................................................ 1 unit* Ref. 0027380 120V - N. America, Taiwan 0027378 230V - United Kingdom 0027381 230V - India 0027379 230V - China 0027382 230V - Europe 0028103 100V - Japan * according to purchased station reference. 2 Features and Connections Stand for B 115T Nano B·iRON Tweezers Cartridge Storage Quick Tip Changer Brass Wool (inside) Antisplash Membrane Console Support Tool Stand and Charger Wiper B·iRON Console 7" Note: for references without console blue tooth device like PC or mobile can be connected. CBolunenteocottihon B 115T Nano B·iRON Tweezers USB Cable (only for charging) USB Connector Screw to detach the Support Power Socket C115 Cartridge Range, not included 3 Quick Start 1. Connection Connect the stand to the mains (100 - 240 V). 2. Cartridge Insertion and Charging 1 2 Insert a cartridge into the tool (1) and place it into the charger on the stand (2). Note: Charge the tool completely (30 min) before using for the first time. Status Indicator Light 4 The status indicator light idicates as follows the tool status: green green blinking alternating red/green blinking red blinking: working/soldering charging low battery, less than 20% no cartridge no color: power OFF 3. Switching on Console/Device JBC 4. Selecting Tool MENU Return to Work Devices JBC Tool1 Tool2 Turn on the console/device and open the B·iRON Application: Select the tool from the detection list. Console Work Screen The work screen shows the graph of the current tip temperature and the power supplied to the tip by moving the graph permantely to the left. Temperature and Power Grafics Application Menu Tool Status MENU 450 ºC JBC 210 WORK Connected Tool JBC#1 24 W 350 ºC 18 W 250 ºC 12 W Battery Level 150 ºC 50 ºC 80% 350ºC 6 W 0 W 10 seconds/div Tool ON V1.2 Tool Status JBC Temperature Selection Slider 5 Operation The JBC Most Efficient Soldering System This revolutionary technology is able to recover tip temperature extremely quickly. This allows the user to work at a lower temperature. Work Charging and Hibernation When the tool is lifted from the stand the tip will heat up to the selected temperature. When the tool is in the stand enters into Hibernation Mode and cools down to room temperature. While the tool remains in the stand, it charges. Note: When the tool is lifted from stand the Soldering System acts as follows: Hibernation Turned Off JBC Turned On long time inactive When the tool is outside of the stand and remains inactive (no movement), the tool enters into Hibernation mode and cools down to room temperature. If the tool has been inactive for a longer period of time, it is turned off. To turn the tool on, put it back into the stand. 6 W Note: If desired, the tool can be swithed off/on. Tab the Tool Power button at the tablet screen (bottom right) to switch it off/on. Tool Power Button 0 W 10 seconds/div Tool ON V1.2 6 JBC Grafics The work screen shows the automatic recording of the temperature and power grafics. The automatic recording can be paused by tapping the screen at the grafic area. The automatic recording stops also when the tool stops working. While the automatic recording is stopped, you can get the temperature/power value on a certain point by tapping the graph on the tablet screen. MENU 450 ºC 350 ºC JBC 210 CHARGE 348ºC JBC#1 24 W 18 W 250 ºC 12 W 150 ºC 6 W 6 W 50 ºC 80% 350ºC When the tool ist not in use the grafics stops recording JBC 0 W 10 seconds/div Tool ON V1.2 The grafic can be moved to the left and right by swiping the touch screen sideways with one finger. The recording starts automatically as soon as the tool is removed from the stand and the graphic automatically jumps to the end of the last recording and continues with the recording. Note: When the tool is placed in the stand and is not in use, the temperature/power recording stops. A gap can then be seen in the curve grafics. 7 Tip Cleaner Select the option to suit your needs and improve the tip thermal transfer. Brass Wool Ref. CL0300 Very effective cleaning method. Leaves a small layer of solder on the tip preventing oxidation between cleaning and rewetting. Wiper Tapping Antisplash Membrane with Wiper Ref. CL0301 The antisplash membrane prevents splashing and keeps the work area clean. Includes a temperature resistant wiper for removing excess solder by gently tapping or wiping the cartridge tip. If the tip is very dirty, JBC recommends first cleaning it with the wiper to remove excess solder and then with the brass wool. Wiping Tap gently to remove excess solder. 8 Use the slots to remove remaining particles. Replacing Brass Wool 1. Lifting 2. Replacing Space Lift and remove the antisplash membrane. 3. Assembling Replace the brass wool with a new one. Make sure that the brass wool is on the far left and that there is space for the wiper on the right. 4. Pressing on Assemble the antisplash membrane in vertical direction onto the stand. Press the antisplash membrane down. Make sure that the membrane is correctly inserted all around. Note: The brass wool and the wiper position can be reversed by rotating the antisplash membrane 180 degrees 9 Quick Tip Changer Save time and change cartridges safely without switching the station off. 1. Removing 2. Inserting 3. Fixing Reference Ring Place the tweezers with the cartridge in the extractor slot and pull to remove it. Place the tweezers on top of the new cartridge and gently push the tweezers down. Place the tweezers with the cartridge in the slot, so that its reference ring rests in the slot, and gently press the cartridge into the tweezers*. *Important: Push the cartridge in as far as it will go, until the reference ring rests against the tweezers. The charging indicator light changes from red to green when the cartridge is proprely inserted. until "stop" Charging Indicator Yes No Reference Ring 10 Cartridge Tip Alignment Nano B·iRON Tweezers offers an intuitive cartrige tip alignment function. Cartridge tips can be rotationally and vertically aligned. Wheel for vertically tip aligntment Bushings for rotationally tip alignment Rotationally Tip Alignment Rotate the bushings slightly (1) to rotationally align the tips (2). 1 Bushings Vertically Tip Alignment Rotate the wheel slightly (1) to vertically align the cartridge tips (2). Wheel 1 2 Not aligned 2 Aligned Compatible Cartridges B 115T Nano B·iRON Tweezers works with C115 Cartridges. Find the model that best suits your soldering needs in www.jbctools.com Tweezer Chisel Tweezer Conical Bent Blade 11 Menu Settings The B·iRON Console offers an intuitive user interface which provides quick access to station parameters. MENU Return to Work JBC 210 JBC#1 Tool ID Tool1 2822 Hibernation delay 00:30 Temperature units ºC ºF Lock Parameters Locked Unlocked Maximum Temperature 400ºC Sleep mode Sleep temperature JB150CºC Tool Status Working Low battery Power OFF Charging No cartridge Parameters Parameter Tool ID PIN Hibernation Delay Sleep Mode / Sleep Temperature Maximum Temperature Tool Status 12 JBC Description Allows to change the tool identifier. Allows to change the PIN JBC Set hibernation delay from 5 to 15 sec. Countdown starts when no movement ist detected. Set sleep mode ON/OFF. The tip temperature will drop to the selected sleep temperature. Allows selection of the maximum temperature that can be set for the work mode The tool status light indicates as follows the tool status: JBC - Green: working / soldering - Green blinking: charging - Alternating red/green blinking: low battery, less than 20% - Red blinking: no cartridge - No color: power OFF JBC JBC B·iRON Update JBC - Download the JBC update file from: https://www.jbctools.com/jbcsoftware.html - Connect the console/device via USB connection to the PC. - On the console/device notification bar at the top, open "USB Connection Settings" and select "MTP". - On the PC copy the downloaded file to "IT706/internal share storage/JBC". - Once copying is finished, disconnect the console/device from the PC. JBC - On the console/device open the Application (1) and then select "update" (2) on the Application Menu. 1 JBC 2 MENU JBC Work Application Menu 450 ºC Settings Counters 350 ºC Update 2D5o0 cºCuments Light Theme 150 ºC Dark Theme - Use the update button of the version to be downloaded. MENU Return to Work JBC 210 50 ºC 80% Disconnect JBC#1 Tool ID Tool1 2822 28714 Hardware Software 0028283 X886787 Update File File Hardware Software Select your Firmware - Update Update Button JBC 13 Maintenance Before carrying out maintenance, always extract the cartridge and disconnect de B·iRON from the mains. Allow the equipment to cool down. - Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts. - Periodically check that the metal parts of the tool and stand are clean so that the charging works properly. - Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation. Rusty and dirty surfaces reduce heat transfer to the solder joint. - Do not use liquid such as alcohol, thinner or benzene to clean the console. - Repairs should only be performed by a JBC authorized technical service. Clean periodically Clean periodically 14 Safety It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. - Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. - The power cord must be plugged into approved bases. When unplugging it, hold the plug, not the wire. - Do not work on electrically live parts. - The tool should be placed in the stand when not in use in order to charge the batteries. - The soldering tip or nozzle, the metal part of the tool and the stand may still be hot even when the station is turned off. - Do not leave the appliance unattended when it is on. - Avoid flux coming into contact with skin or eyes to prevent irritation. - Be careful with the fumes produced when soldering. - Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm. - Utmost care must be taken with liquid tin waste which can cause burns. - This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance. - Maintenance must not be carried out by children unless supervised. - Do not expose the console to high temperatures, humidity or dust. Avoid direct sunlight. - Do not drop the console as it may cause damage or malfunction. - Do not disconnect your device when it is in file transfer mode. - Do not use the console in places were electronic devices are resticted. 15 Notes 16 Notes 17 Notes 18 Specifications B·iRON 115T Nano Tweezers B·iRON Station With Console: Ref. BI115TUA 120 V - N. America, Taiwan Ref. BI115TIA 230 V - India Ref. BI115TA 230 V - Europe Ref. BI115TKA 230 V - United Kingdom Ref. BI115THA 230 V - China Ref. BI115TJA 100 V - Japan Without Console: BI115TUQA 120 V - N. America, Taiwan BI115TIQA 230 V - India BI115TQA 230 V - Europe BI115TKQA 230 V - United Kingdom BI115THQA 230 V - China BI115TJQA 100 V - Japan Stand: - Input: - Power: - Tool output: - USB output: 100 V - 240 V 50/60 Hz 15 W 12 V / 350 mA 5 V / 1000 mA Tool: - Output Peak Power: - Battery: - Charge Time: - Temperature Range: - Idle Temp. Stability (still air): - Temp. Accuracy: - Connections: - Ambient Operating Temp: - Tool Weight: 5 W Li-Ion 7.4 V / 180 mAh 40 minutes 200 - 450 °C / 390 - 840 °F ±1.5 °C / ±3 °F ±3% (Using reference cartridge) Bluetooth Low Energy (BLE) 10 - 50 °C / 50 - 122 °F 55 g / 0.12 lb With Console - Total Net Weight: - Total Package Dimensions/Weight: (L x W x H) 1462 g / 3.22 lb 265 x 223 x 160 mm / 2020 g 10.43 x 8.78 x 6.30 in / 4.45 lb Without Console - Total Net Weight: - Total Package Dimensions/Weight: (L x W x H) 998 g / 2.20 lb 225 x 223 x 160 mm / 1556 g 8.86 x 8.78 x 6.30 in / 2.34 lb Complies with CE standards ESD safe Not grounded device. No ESD discharge feature. 19 Warranty JBC's 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warranty does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase. This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility. 0028298-080722