User Manual for Power Technologies models including: CNC-10TM CNC Machining Center, CNC-10TM, CNC Machining Center, Machining Center, Center
1 day ago — CNC-10™ effectively kills 99.9% of infectious pathogens from laptops, tablets, headphones, VR headsets, and other electronic devices. The UV absorbing ...
22 hours ago — CNC-10™ effectively kills 99.9% of infectious pathogens from laptops, tablets, headphones, VR headsets, and other electronic devices. The UV absorbing ...
File Info : application/pdf, 17 Pages, 4.07MB
DocumentDocumentCNC-10TM 10 BAY CHARGING & UV-C SANITIZING CABINET USER MANUAL Product Information Designed to charge, securely store and sanitize 10 devices upto 14 inches. Specifications: Model CNC-10TM Cabinet Dimensions Inch 19.5 (H) x 19(W) x 13.5(D) cm 49.5 (H) x 48.2 (W) x 34.2 (D) Product weight (Without Devices) Capacity Supported Devices Power Specifications (For Cabinets sold within North America) Power Specifications (For Cabinets sold outside North America) Charging Type 52 lbs. (23.5 kg) 10 Laptops/Tablets - Configurable Interior Devices up to 14 Inch (356 mm) AC IN/ Power Strip: 110V AC, 50/60Hz, 10A Maximum power: 1200W AC IN/ Power Strip: 100-240V AC, 50/60Hz, 10A Maximum power: 2000W Basic Charging, 65 Watt USB-C Charging Hub Security Front door 3-point mechanism with key lock Sanitize Type Bulb Specification Bulb Wattage UV-C Light Sanitization 360° reach 8 lamps & reflective lining Virtually Eliminate Blind Spots, mecury based bulb 16 Watts (assumed) Bulb Life more then 6000 hours Adapter Shelves Loading (ea.) 6.6 lbs (3 kg) Working Temperature 0°- 30°c Working RH% 10% - 90% Storage Temperature -40°- 60°C Temp Storage RH% 5% - 95% Warranty Lifetime Frame, 2 Years Components, 2 Year Electronics Specifications subject to change without notice. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 2 Product Information This manual covers the following models and part numbers. The manual is based upon the North American 110V product offering. Refer to the part numbers below and cord end diagrams for your specific region. MODEL# CNC-10TM SKU CAB-CNC-B10K-D CAB-CNC-B10K-E CAB-CNC-B10K-U CAB-CNC-B10K-A CAB-CNC-B10K-S DESCRIPTION CNC-10, 10 Bay UV-C Sanitizing & Charging Cabinet - 110V NA CNC-10, 10 Bay UV-C Sanitizing & Charging Cabinet - 220V EU CNC-10, 10 Bay UV-C Sanitizing & Charging Cabinet - 220V UK CNC-10, 10 Bay UV-C Sanitizing & Charging Cabinet - 220V AU CNC-10, 10 Bay UV-C Sanitizing & Charging Cabinet - 220V SW Power Cords and Sockets for Specific Region: US / Canada Socket United Kingdom Power Cord Plug Socket European Power Cord Plug Socket Australian Power Cord Plug Socket Switzerland Type-J Power Cord Plug Socket Power Cord Plug 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 3 Product Information The CNC-10TM is designed to charge store & disinfects up to 99.9% of bacteria from Chromebooks, Laptops, tablets. NOTE: Please review this guide before installing devices and to learn how to safely use your cart. Keyed Door Touchscreen Interface Handle Front View of Cabinet 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 4 Product Information · If the device (Laptop / Chromebook) thickness is more than the gap between the SS racks, adjust SS racks to create enough space for your device. Top Panel / USB Hub Removable Service Panel Lock Mechanism & internal Wiring Carry Handle (Both sides) Adjustable Medical Grade SS Racks Front View of Cabinet Power cord port 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 5 Product Information · Removable and lockable top panel area is used to place power adapters. Electromagnetic Lock Door Lock Sensor Power Module Power Cord Rear View of Cabinet 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 6 Product Information Internal Configurations : CNC-10 comes with two additional racks in addition to the divider base and top rack allowing charging space to be configured to meet device needs. Device Divider and Top Rack. Bottom & Center Shelf. Bottom Shelf Only. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 7 User Instructions Operation and User Interface Using the CNC-10 is very simple; unlock door and load the device into the cabinet, plug device it it's a pre-loaded charging cable. CNC-10 will charge the device based upon device's settings. Once charged CNC-10 provides a maintenance charge keeping devices ready for use. Unlock and lock the cabinet via the control panel. Cabinet is equipped with an electro-magnetic lock that engages while the unit is powered. A mechanical key lock is available for additional security and administrative use. Press Lock Icon to lock and unlock the door. Cabinet door will not unlock during UV-C disinfection. Press stop to end UV-C disinfection to activate the lock button UV-C Disinfection Countdown Timer Set Disinfection Time: + or in 1-minute increments Start UV-C UV-C bulb life used (hours) Stop UV-C Unlock Cabinet door UV-C bulb life is monitored by the bulb life countdown meter. Press the "bulb" icon to see the number of hours bulb has been in use. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 8 User Instructions Care and Maintenance: Keep the cabinet exterior clean with a mild cleaner on a soft cloth for exterior surfaces. Interior service should be cleaned via compressed air once a month or as needed. Medical grade stainless steel racks should be wiped down with mild cleaner once a month or as needed. UV-C bulb has a bulb life count down feature on the control panel and bulbs should be replaced around the 10 hour mark. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 9 Determining Time The germicidal properties of the (8) 254 nm UV-C bulbs used in the CNC-10TM are documented to provide up to 4-log (99.99%) disinfection with just 2 minutes of exposure time. Additional time settings may be used for other organisms not listed. The following list is provided as a guide of which organisms become deactivated within 2 minutes: Bacteria Bacillus anthracis B. megatherium sp. (spores) B. megatherium sp. (veg.) B. parathyphosus B.suptilis B. suptilis spores Campylobacter jerjuni Clostridium tetani Corynebacterium diphteriae Dysentery bacilli Eberthella typhosa Escherichia coli Klebsiella terrifani Legionella pneumophila Micrococcus candidus Micrococcus sphaeroides Mycobacterium tuberculosis Neisseria catarrhalis Phytomonas tumefaciens Pseudomonas aeruginosa Pseudomonas fluorescens Proteus vulgaris Salmonella enteritidis Salmonella paratyphi Salmonella typhimurium Sarcina lutea Seratia marcescens Shigella paradysenteriae Shigella sonnei Spirillum rubrum Staphylococcus albus Staphylococcus aureus Streptococcus faecalis Streptococcus hemoluticus Streptococcus lactus Streptococcus viridans Sentertidis Vibrio chlolerae (V.comma) Yersinia enterocolitica Yeasts Bakers' yeast Brewers' yeast Common yeast cake Saccharomyces cerevisiae Saccharomyces ellipsoideus Saccharomyces sp. Mould Spores Aspergillus flavus Aspergillus glaucus Aspergillus niger Mucor racemosus A Mucor racemosus B Oospora lactis Penicillium digitatum Penicillium expansum Penicillium roqueforti Rhizopus nigricans Viruses Hepatitis A Influenza virus MS-2 Coliphase Polio virus Rotavirus Note: This UV-C product is not approved and/or certified as a medical device. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 10 Installation Instructions Accessing Charging hub and wiring for your devices Access CNC charging hub by unlocking top panel, lift panel using provided handle. Plug USB-C device cables into Charging hub ports. Wrap excess cable around strain relief bar tabs to adjust cable length. Drop device cables through holes in cabinet 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 11 Fitting Devices Inside Cabinet SETTING UP DEVICES: Step-1: Open the door Step-2: If your devices are less than 7.25" wide, place them directly onto the shelves. Step-3: If your devices are more than 7.25" wide, remove the thumbscrews from the left/ right sides and pull the center shelf out. Step-4: Place devices so that all surfaces are completely exposed. Step-5: If needed, place less items inside to avoid crowding. Step-6: Begin Disinfection process 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 12 Disinfecting Of Devices Disinfect and charge laptops, tablets, and other electronic devices. Overview: Support infection control initiatives with ultraviolet (UV-C) light sanitization to encourage more frequent disinfection without the use of corrosive chemicals. CNC-10TM effectively kills 99.9% of infectious pathogens from laptops, tablets, headphones, VR headsets, and other electronic devices. The UV absorbing, transparent window with electro-magnetic locking system keeps users safe while devices are being disinfected. Disinfection cycle times, from 2 minutes to 20 minutes, can be customized depending on workflow and efficacy needs. CNC-10TM customizable charging for up to 10 electronic devices. Designed with the highest level of flexibility and versatility in mind, CNC-10TM offers the ability to configure medical grade stainless steel racks to adapt to devices of varying shapes and sizes. Integrated cable management and lockable power adapter storage area keep cables organized and secure. Disinfect: · Medical Grade Stainless Steel Racks. · Chemical-free UV- surface disinfection process. · Sanitizes Exposed Surfaces. · Locker Power Adapter Storage Area with Removable Top Panel. · Effectively kill 99.9% of infectious pathogens like influenza, the common cold and coronavirus. · 360° reach eight lamps & reflective lining Virtually Eliminate Blind Spots. · Customizable disinfection cycle times. · Integrated Cable Management. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 13 Bulb Life & Replacement CAUTION: UV Lamps contain mercury - manage in accordance with your local disposal laws. A lamp breaking is extremely unlikely to have any impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove the parts, preferably with gloves. Put them in a sealed plastic bag and take it to your local waste facilities for recycling. Do not use a vacuum cleaner. For maximum efficiency, change bulbs when one no longer works or more than 6,000 hours. Step-1: With your unit unplugged from an electrical outlet, open the door. Step-2: Remove the thumbscrews from the left side and pull the upper, middle & lower shelves out. Step-3: Wearing cotton gloves, rotate the old bulb counter clockwise to release it from the lamp socket. Install new bulb by placing into lamp socket and rotating clockwise until you hear a click. Step-4: Plug the unit back into an electrical outlet and reset the Bulb Use Hours counter by pressing "Bulb Use" for 6 seconds. Then, enter "0 - 3 - 1 - 4" when prompted. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 14 Safety Instructions Caution Notice DO NOT place liquids on or near the cabinet. THIS IS NOT A TOY. ALWAYS FOLLOW SAFETY INSTRUCTIONS. Important Danger Warning Don't connect the cart with broken electrical components. THE ELECTRICAL SYSTEM IS DESIGNED TO HANDLE A MAXIMUM OF 1400 WATTS per side. If wattage exceeds 1400W at one time, charging system may not operate correctly. Remove devices until the total wattage is under 1200W. · ALWAYS move the cabine slowly and be aware of our surroundings. · Used or broken bulbs should be disposed of in accordance with all applicable disposal laws. · Repairs should always be performed by a qualified electrician. · Set the power switch to the OFF position before you unplug the unit from the wall, plug the unit into the wall, or plug in devices. · Do not touch bulbs or ballasts. · Do not alter the construction or design. Do not remove safety labels or devices. · Do not use this product around flammable or combustible materials. DO NOT block fan or vent opening This UV-C product is not approved and/or certified as a medical device. DO NOT touch any part of the electrical system while plugged in. For warranty claims, please have the following information ready, then visit www.powertechnologies.com to create a help ticket. DO NOT use an extension cord with this unit. Serial Number: -----------------------------------------------------------Charging System Type: DO NOT allow children to move or climb. -----------------------------------------------------------Date Of Purchase: Ultraviolet light. Avoid eye and skin -----------------------------------------------------------Reseller Name: -----------------------------------------------------------PO Number: DO NOT over extend the power cord ------------------------------------------------------------ 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 15 Troubleshooting If one or more bulbs is not working, follow these steps before replacing: Step-1: With your unit unplugged from an electrical outlet, open the door. Step-2: If your devices are less than 7.25" wide, place them directly onto the shelves. Step-3: If your devices are more than 7.25" wide, remove the thumbscrews from the left/right sides and pull the center shelf out. Step-4: Place devices so that all surfaces are completely exposed. Step-5: If needed, place less items inside to avoid crowding. Step-6: Begin Disinfection process 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 16 Further Information For further information on this product and others, contact Power Technologies at. Power Technologies 42035 Zevo Dr Temecula, CA 92590+ 888.650.4488 support@powertechnologies.com www.powertechnologies.com 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-03 17