Contact-type tachometer Instruction Manual
MEM Contact-type tachometer
Version8906-EN-00

I.Introduction
Tachometer is one of the necessary instruments in machinery industry, which is used to measure rotation speed, linear speed or frequency of electric motor, as well as rotation speed of impeller blades, roller and shaft. It is widely used in industries like electric motor, fan, washing machine, textile, automobile, aircraft, ships, etc.
Features: 1. Maximum value, minimum value, average value, last
measured value holding. 2. Clear operation instructions and full display of unit
symbol 3. A wide range of measurement, high resolution. 4. Low battery indicator, LCD backlight display,
automatic shutdown. 5. With combination of latest microprocessor
technology and laser technology, the instrument is more intelligent and more reliable. 6. Large LCD screen display, clear reading. 7. Solid and ingenious structure. The whole machine adopts durable and optimized electronic components, and light but hard ABS plastic for the shell, which is good-shaped and user-friendly.
II.LCD display

a.Low battery indicator

a

b.Backlight indicator

c.Measurement signal

d.Max value

e d

e.Min value

f. Last value

g.Average value

h

h.Rotation speed I.Rotation speed unit i

bc
f g

III.Operation instruction

1.Turn on/off and backlight

Short press / long press power button to turn on the

instrument, then short press power button to turn on / off

backlight, long press power button to turn off instrument.

2.Automatic shutdown

Short press power button to turn on the instrument, and

full screen display lasts 1s. After no operation under no

measurement state for 1 min, automatic shutdown starts.

Long press power button to turn on the instrument, UOFF

indicator shows first and full screen display follows, which

is not automatic shutdown state.

3.Start / stop measurement

Short press

butoon to turn on / off measurement.

Measurement is off by default after turning on the

instrument, CLOSE is displayed on the screen when the

measurement is off, if measurement is on, real-time rotation

speed is displayed.

Note: All MAX / MIN / LAST / AVG values saved before

turning on the measurement will be cleared.

4.Switch unit

Long press MEM button to switch among RPM, m / min,

ft / min.

5.Check MAX / MIN / LAST / AVG value

Under CLOSE state, short press MEM button to

sequentially check the MAX, MIN, LAST, AVG values saved

in the previous measurement.

Under measurement state, short press MEM button to

sequentially check real-time MAX, MIN, LAST and AVG

values.

6.Low battery indicator

when battery voltage is lower than 2.2V, the battery

indicator flashes, and batteries should be replaced in time.

IV.Technical parameters

Measure range Resolution rate Accuracy rate Sample interval Power Size

0.5~19999 0 . 10 . 5 ~ 9 9 9 . 9 )11 0 0 0 ~ 1 9 9 9 9 ) 0.05%+1 0.8s(60RPM or above)
Two 1.5V AAA batteries 55.0*33.0*157.8mm

Specific Declarations: Our company shall hold no any responisibility resulting from using output from this product as an direct or indirect evidence. We reserves the right to modify product design and specification without notice.

