User Manual for Photonic Universe models including: WWS30A-48-L00-S00, HCM2000-48-48 Module Wind Turbine Controller with MPPT, HCM2000-48-48, Module Wind Turbine Controller with MPPT, Wind Turbine Controller with MPPT, Turbine Controller with MPPT, Controller with MPPT, MPPT

11、WWS30A-48-L00/S00

User Manual


File Info : application/pdf, 15 Pages, 561.06KB

PDF preview unavailable. Download the PDF instead.

HCM2000-48-48
MWM Series Module Wind Turbine Controller with MPPT
User Manual
Product Model HCM2000-48-48
V1.3

Contents
1. Important Safety Warning ......................................................................................................... 2. Basic Information........................................................................................................................
2.1 Introduction and Features ....................................................................................................... 2.2 Product Structure .................................................................................................................... 3. Product Installation ....................................................................................................................... 3.1 Installation Notes .................................................................................................................... 3.2 Installation and Wiring............................................................................................................ 3.2.1 Installation Steps.................................................................................................................. 3.2.2 Installation Steps.................................................................................................................. 3.2.3 Electrical Connection........................................................................................................... 4. Operation Interface Introduction............................................................................................. 4.1 LCD Display ....................................................................................................................... 4.2 LCD Information Define..................................................................................................... 5. Trouble Shooting ........................................................................................................................ 6. Technical Parameters................................................................................................................. 7. Warranty..................................................................................................................................
V1.3

1. Important Safety Warning
Before Using the controller, please read all instructions and cautionary markings on the unit and this manual. Store the manual where it can easily be accessed.
This manual includes all safety warnings, installation, and operation guidance of MWM wind controllers.  Before installing and using this controller, read all instructions and cautionary markings on the
controller and all appropriate sections of this guide.  Do not use the machine in the place where has flammability and explosive gas/articles. Beware
of flames and sparks.  Please Contact our after-sales person if the machine doesn't work.  Do not change the electrical components and parts yourself, or we will not be responsible for the
warranty items and related duties.  Please disconnect the AC input and DC output from controller before install or maintain the
machine. Besides, do not touch the controller in 5 mins after disconnection.  Please install the machine indoor to avoid the rain water enter the controller inside.  Please keep good ventilation and heat dissipation.  Please install a circuit breaker outside the controller if conditions are allowed.  Please use copper cable for line connection, and choose the right diameter of cable according to
the actual current.  To avoid a risk of fire and electric shock, make sure the existing wiring is in good condition and
that the wire is connected tightly.  Do not restart the controller immediately when it alarms. Please analyze the fault reasons and
repair them at first.



V1.3

2. Basic Information
2.1 Introduction and Features
The MWM series wind power generation controller is the controller which integrates MPPT control and charge and discharge control. The power curve can be set by setting the wind turbine voltage and current, which can ensure the wind turbine work with the best power output all the time.
Features:  Can be applied to grid-tied system, off-grid system and grid-tied energy storage system. Charge
function is optional.  MPPT track point settable  Complete protection function  Electrical components and parts in high quality.  Several functions are optional, such as PV control function, wind speed measure function,
rotational speed control function and temperature compensation function.  RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee optional. ( It can be monitored by app for those
with GPRS/Bluetooth/RJ45 connection)



V1.3

2.2 Product Structure

Chart1. Product Overview (1-3kW)



V1.3

Chart2. Product Overview (5-10kW)



Battery terminal





Dump load terminal





Wind turbine terminal





Communication device port



Manual brake switch Browse button LCD display
Unload indicator light



V1.3

Chart3: Dump Load with different power
3. Product Installation
3.1 Installation Notes
1) The machine should be kept indoors and well ventilated; 2) Environment temperature: -20+40; Humidity: <=95%no condensing 3) Altitude should not be more than 4000m (1000 m derating according to the GB/T3859.2
regulations). 4) Avoid using the machine in direct sunlight, sun exposure, rain, humidity, acid fog, and dust. 5) The machine can only charge for the battery in the rated voltage range. 6) The machine can only be connected to the wind turbine and PV with allowed power and voltage.



V1.3

3.2 Installation and Wiring
3.2.1 Installation Steps

Chart 4: Installation Overview



V1.3

3.2.2 Installation Steps

Chart5: Installation Steps



V1.3

3.2.3 Electrical Connection

(1-3kW)



V1.3

(5-10kW)
Chart 6: System Overview Please connect those parts according to the order of , and notice the following items. 1. Connect Dump load to the controller terminal "DUMPLOAD" by using copper conductor cable. 2. Connect the battery bank to the controller by the terminal which marks "BATTERY". (do not
reversed the connection of positive and negative terminals) 3. When wind turbine is still or running in a low speed, connects its output cable to the "WIND
INPUT" terminal on the controller. 4. Check all the connection to make sure they are connected rightly and tightly.



V1.3

4. Operation Interface Introduction
4.1 LCD Display
After the power is connected, the whole screen is in a browsing status. It shows battery voltage, and can be changed to the following information by press related buttons.

4.2 LCD Information Define

Name

Icon

Wind Turbine

Battery

Browse button

Status Rotate means wind turbine works normally Brake by hand
Charging Fully charged. flickering for over voltage, stop flickering when it recover from over voltage Flickering means over -discharge Press it to enter next LCD display. Press it for 5s to enter the brake status Press it for another 5s to recover charging status.



V1.3

Dump load indicator light

Red light is on means the machine is on unload status or brake status. The light is off when it works normally.

5. Trouble Shooting

Fault Type

Description

Possible reasons and solutions

The connection between the battery and the controller is not tight

Check the wiring, and reconnect it.

DC breaker is not on between battery and Turn on the breaker
controller

No display on LCD
Low battery voltage

The system parameters are not matched correctly. Recheck the label and parameters on the machine.

The battery doesn't work. Change a new one.

Battery is connected in wrong polarity to Need change the internal fuse in

battery input terminals.

controller, and reconnect the battery.

The connection cable between wind turbine and controller is loose. Wind turbine output voltage hasn't reached the charging voltage,

Reconnect and fix the cables.
Check whether the system voltage is reasonable.

No charging Wind turbine is in "Brake" status

Wait the wind turbine recover if it
brakes automatically. Press the button for 5s to release the brake status if it brakes by hand.

Battery is already fully charged.

Check if the battery voltage has reached its output overvoltage.



V1.3

6. Technical Parameters

Model

HCM2000-48-48

Type

Boost

Wind Turbine Input

Rated input power

2kW

Rated input voltage

48V

Input voltage range

0~64V

Start charge voltage

12Vdc (factory default, 8Vdc~64Vdc settable)

Rated input current

42A

Brake by hand

Keep press the button for 5s to unload completely, and then recover by hand. Switch "ON" the brake switch

Brake by over current

42A (factory default, 0~50A settable)unload completely when reached the set current, and recover automatically after working 10mins.

Brake by overvoltage

Refer to "output overvoltage" control

Charge Parameters

Rated battery voltage

48V

Start unload voltage Complete unload voltage Max. Output current

56Vdc (factory default, 44Vdc~64Vdc settable) 58Vdc (factory default, add 2V to the start unload voltage)
42Adc

General Parameters

Rectifier mode

Uncontrolled rectifier

Display mode

LCD

Display information

DC output voltage, wind turbine voltage/current/power. For those with charge control function, Battery voltage is showed as well.

Monitoring mode Monitoring Contents

RS232 Real-time display: DC output voltage, wind turbine voltage/current/power.



V1.3

For those with charge control function, Battery voltage is showed as well.

Lightning protection

Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, and wind turbine brake settings.
YES

Conversion efficiency Static loss

92% 2W

Ambient temperature

-20+40

Humidity

0~90%, No condensing

Noise

65dB

Cooling mode

Forced air cooling

Installation mode

Wall-mounted

Cover protection class Product dimension (W*H*D) Product net weight Dump load dimension (W*H*D) Dump load net weight

IP42 300×375×145mm
10kg 400*300*210mm
9.5kg

Note: Part of parameters can be adjusted according to customer's specific demand.

7. Warranty

The product shall be in warranty for one year from production. Please take contract as the final one if it has special terms on warranty.



V1.3


Microsoft Word 2016