User Manual for PPI models including: LabCon Recording PC Software, LabCon, Recording PC Software, PC Software, Software
Temperature control system | Temperature Recorders India - PPI controller
File Info : application/pdf, 1 Pages, 431.55KB
DocumentDocumentLabCon (PC) Recording + PC Software OPERATOR PAGE PARAMETERS Parameters Settings (Default Value) Time Start Command >> Time Abort Command >> Time Interval (H:M) >> Ctrl Set Value >> Ctrl Lo Deviation >> Ctrl Hi Deviation >> Change Password >> Yes No (Default : No) 0.00 to 500.00 (HH:MM) (Default : 0.10) Setpoint LO limit to Setpoint HI limit (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 25.0) For RTD & DC Linear: 0.2 to 99.9 For Thermocouple: 2 to 99 (Default : 2.0) For RTD & DC Linear: 0.2 to 99.9 For Thermocouple: 2 to 99 (Default : 2.0) 1 to 100 (Default : 0) SUPERVISORY > SENSOR INPUT Parameters Settings (Default Value) Ctrl Zero Offset >> -50 to 50 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 0.0) SUPERVISORY > RECORDING Parameters Settings (Default Value) Rec. Interval (min) >> 0 to 250 Min (Default : 5 Min) Alarm Toggle Record >> Enable Disable (Default : Enable) Del PC Records >> Yes No (Default : No) Del Display Record >> Yes No (Default : No) GSM Machine ID >> (refer note) 1 to 128 (Default : 1) RTC Time >> RTC Date >> 0 to 23 for Hour 0 to 59 for Min (Default : NA) 1 to 31 (Default : NA) RTC Month >> 1 to 12 (Default : NA) RTC Year >> Device Id >> 2000 to 2099 (Default : NA) 1 to 127 (Default : 1) SUPERVISORY > CONTROL Parameters Settings (Default Value) Tune >> Yes No (Default : No) Setpoint LO Limit >> Min Range for the Selected Input Type to Setpoint HI Limit (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 0.0) Setpoint HI Limit >> Setpoint LO Limit to Max Range for the Selected Input Type (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 600.0) Compressor Setpoint >> Compressor Hyst >> 0 to 100 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 45.0) 0.1 to 99.9 (Default : 2.0) Heat Ctrl Action >> ON-OFF PID (Default : PID) Heat Hyst >> 0.1 to 99.9 (Default : 0.2) Heat Only Control Heat + Cool Control Zone : Single Heat + Cool Control Zone : Dual Proportional Band >> Proportional Band >> PrCozpoPrrtioopnaBl aBnadnd>>for 0.1 to 999.9 0.1 to 999.9 Cool Pre-dominant zone (Default : 50.0) (Default : 50.0) 0.1 to 999.9 (Default : 50.0) Integral Time >> 0 to 3600 sec (Default : 100 sec) Integral Time >> 0 to 3600 sec (Default : 100 sec) CzInItnetgergarlaTlimTiemfeor>> Cool Pre-dominant zone 0 to 3600 sec (Default : 100 sec) Derivative Time >> 0 to 600 sec (Default : 16 sec) Derivative Time >> 0 to 600 sec (Default : 16 sec) Cz Derivative Time >> Derivative Time for Cool Pre-dominant zone 0 to 600 sec (Default : 16 sec) Cycle Time >> 0.5 to 100.0 sec (Default : 10.0 sec) Cycle Time >> 0.5 to 100.0 sec (Default : 10.0 sec) PrHozpoPrrtoiopnaBl aBnadnd>>for Heat Pre-dominant zone 0.1 to 999.9 (Default : 50.0) Overshoot Inhibit >> Enable Disable Overshoot Inhibit >> Enable Disable HzInIntetgergarlaTlimTiemfeor>> Heat Pre-dominant zone (Default : Disable) (Default : Disable) 0 to 3600 sec (Default : 100 sec) Cutoff Factor >> 1.0 to 2.0 sec (Default : 1.2 sec) Cutoff Factor >> 1.0 to 2.0 sec (Default : 1.2 sec) Hz Derivative Time >> Derivative Time for Heat Pre-dominant zone 0 to 600 sec (Default : 16 sec) Cycle Time >> 0.5 to 100.0 sec (Default : 10.0 sec) Overshoot Inhibit >> Enable Disable (Default : Disable) Cutoff Factor >> 1.0 to 2.0 sec (Default : 1.2 sec) SUPERVISORY > PASSWORD Parameters Settings (Default Value) Change Password >> 1000 to 1999 (Default : 123) SUPERVISORY > EXIT Parameters Settings (Default Value) Exit Setup Mode >> Yes No (Default : No) FACTORY > CONTROL SENSOR INPUT Parameters Settings (Default Value) Input Type >> Refer Table 1 (Default : RTD Pt100) Signal LO >> Input Type 0 to 20mA 4 to 20mA 0 to 5V 0 to 10V 1 to 5V Settings 0.00 to Signal High 4.00 to Signal High 0.000 to Signal High 0.00 to Signal High 1.000 to Signal High Default 0.00 4.00 0.000 0.00 1.000 Signal HI >> Input Type 0 to 20mA 4 to 20mA 0 to 5V 0 to 10V 1 to 5V Settings Signal Low to 20.00 Signal Low to 20.00 Signal Low to 5.000 Signal Low to 10.00 Signal Low to 5.000 Default 20.00 20.00 5.000 10.00 5.000 Range LO >> Range HI >> -199.9 to RANGE HI (Default : 0.0) RANGE LO to 999.9 (Default : 100.0) FACTORY > ALARM PARAMETERS Parameters Settings (Default Value) Hysteresis >> 0.1 to 99.9 (Default : 0.2) Inhibit >> Yes No (Default : Yes) Operation Manual This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar - 401 210. Sales : 8208199048 / 8208141446 Support : 07498799226 / 08767395333 E: sales@ppiindia.net, support@ppiindia.net FACTORY > HEAT COOL SELECT Parameters Control Strategy >> Settings (Default Value) Heat Only Cool Only Heat + Cool (Default : Heat + Cool) Control Strategy : Cool Only Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) Control Strategy : Heat + Cool Compressor Strategy >> CONT. OFF CONT. ON SP BASED PV BASED (Default : CONT. ON) CONT. ON Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) SP BASED Boundary Set Value >> 0 to 100 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 45.0) PV BASED Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) Control Zones >> Single Dual (Default : Single) Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) FACTORY > SOAK TIMER PARAMETERS Parameters Settings (Default Value) Enable >> No Yes (Default : No) Start Band >> 0 to 999.9 (Default : 0.5) Holdback Strategy >> None Up Down Both (Default : None) Hold Band >> Heat Off >> 0.1 to 999.9 (Default : 0.5) No Yes (Default : No) Cool Off >> No Yes (Default : No) Power Recovery >> Abort Restart Continuous (Default : Restart) FACTORY > DOOR OPEN Parameters Settings (Default Value) Enable >> Yes No (Default : No) Switch Logic >> Door Alrm Dly (sec) >> Close : Door Open Open : Door Open (Default : Close : Door Open) 0 to 1000 Sec (Default : 60 Sec) FACTORY > MAINS FAILURE Parameters Settings (Default Value) Enable >> Yes No (Default : No) Switch Logic >> Close : Mains Fail Open : Mains Fail (Default : Close : Mains Fail) FACTORY > SMS ALERT Parameters Settings (Default Value) Enable >> (refer note) Yes No (Default : No) Reset GSM Module >> (refer note) Yes No (Default : No) Note : These parameters are available only if the controller supplied with GSM module version. FACTORY > PASSWORD Parameters Settings (Default Value) Change Password >> 2000 to 2999 (Default : 321) FACTORY > FACTORY DEFAULT Parameters Settings (Default Value) Set To Default >> Yes No (Default : No) FACTORY > EXIT Parameters Settings (Default Value) Exit Setup Mode >> Yes No (Default : No) PV ERROR INDICATIONS Message OPEN OVR UNR Error Type Cause Sensor Open Sensor (RTD Pt100) Broken / Open Over-range Temperature above Max. Specified Range Under-range Temperature below Min. Specified Range What it means Type J Thermocouple Type K Thermocouple Type T Thermocouple Type R Thermocouple Type S Thermocouple Type B Thermocouple Type N Thermocouple TABLE 1 Range (Min. to Max.) 0 to +960°C -200 to +1376°C -200 to +385°C 0 to +1770°C 0 to +1765°C 0 to +1825°C 0 to +1300°C Resolution Fixed 1°C Reserve Reserved for customer specific Thermocouple type not listed above. The type shall be specified in accordance with the ordered (optional on request) Thermocouple type. 3-wire, RTD Pt100 0 to 20mA DC current 4 to 20mA DC current 0 to 5.0V DC voltage 0 to 10.0V DC voltage 1 to 5.0V DC voltage -199.9 to 600.0°C -199.9 to 999.9 units Fixed 0.1°C Fixed 0.1 unit FRONT PANEL KEYS Symbol Key Scroll Alarm Acknowledge DOWN UP Function Press to scroll through various Process Information Screens in Normal Operation Mode. Press to acknowledge and mute (if active) alarm output. Press to decrease the parameter value. Pressing once decreases the value by one count; keeping pressed speeds up the change. Press to increase the parameter value. Pressing once increases the value by one count; keeping pressed speeds up the change. SET-UP ENTER Press to enter or exit set-up mode. Press to store the set parameter value and to scroll to the next parameter. ELECTRICAL CONNECTIONS SOAK START ACK BATTERY 01 234 COMMON DOOR RS485 Control Outputs COMM HTR CMP ALM +DEV- +PC- + - + - + - 9 10 11 12 13 14 15 16 17 18 LabCon (w/o map) Configuration PC Printer Recording 5678 Pt100 ++mVA + - TC Supply 18~32VDC +- 19 20 21 Jan 2022