Installation Guide for LS models including: XGF-AH6A Programmable Logic Controller, XGF-AH6A, Programmable Logic Controller, Logic Controller, Controller
File Info : application/pdf, 2 Pages, 899.55KB
DocumentDocumentC/N: 10310000984 Programmable Logic Controller XGT Analog XGF-AH6A PLC . . 1 / . . , , , Short, . . . . . , . . . . 2 . No 1 055 2 -2570 3 595%RH, 4 595%RH, - 5f<8.4 - 3.5mm 5 8.4f150 9.8(1g) - 5f<8.4 - 1.75mm X,Y, Z 10 8.4f150 4.9(0.5g) - - IEC 61131-2 3 . 1) XGI CPU : V2.1 2) XGK CPU : V3.0 3) XGR CPU : V1.3 4) XG5000 Software : V3.1 4 (mm) . 6 / DC 1~5V DC 0~5V DC 0~10V DC -10~10V DC 4~20mA 1/8,000 ±0.2% (25) ±0.3% (0~55) DC 1~5V DC 0~5V DC 0~10V DC -10~10V DC 4~20mA 1/8,000 ±0.2% (25) ±0.3% (0~55) 7 1) . . 2) , , AWG22(0.3) . 3) , . 4) . 5) . 1) CH0 + - IN0 V0+ IN0 I0+ IN0 COM0 R R R CH3 + - 2) CH0 + - IN3 V3+ IN3 I3+ IN3 COM3 R R R IN0 V0+ IN0 I0+ IN0 COM0 R R R CH3 + - IN3 V3+ IN3 I3+ IN3 COM3 R R R 3) 4) OUT0_V0+ OUT0_I0+ OUT0_COM0 OUT1_V1+ OUT1_I1+ OUT1_COM1 CH0 CH1 + 1K ~ 1M - + 1K ~ 1M - OUT0_V0+ OUT0_I0+ OUT0_COM0 OUT1_V1+ OUT1_I1+ OUT1_COM1 CH0 CH1 + 600 - + 600 - 5 . 1) . . . 2) . . . . 2 . 250(typ.). 1(min.). 8 18. 1) ·· 2) 3) 4) 5) · 6) · . LS ELECTRIC Co., Ltd. www.ls-electric.com 10310000984 V4.4 (2021.11) ! ( ) 1544-2080 TEL:(02)2034-4623~38 TEL:(051)310-6855~60 TEL:(053)603-7741~8 () TEL:(062)510-1891~92 () TEL:(042)820-4240~42 FAX:(02)2034-4057 FAX:(051)310-6851 FAX:(053)603-7788 FAX:(062)526-3262 FAX:(042)820-4298 (): 4 56 ( 31226) C/N: 10310000984 Programmable Logic Controller Installation Guide XGT Analog XGF-AH6A This installation guide provides simple function information of PLC control. Please read carefully this data sheet and manuals before using products. Especially read safety precautions and handle the products properly. 1 Safety Precautions Meaning of warning and caution inscription WARNING WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. WARNING Do not contact the terminals while the power is applied. Protect the product from being gone into by foreign metallic matter. Do not manipulate the battery(charge, disassemble, hitting, short, soldering). CAUTION Be sure to check the rated voltage and terminal arrangement before wiring. When wiring, tighten the screw of terminal block with the specified torque rage. Do not install the flammable things on surroundings. Do not use the PLC in the environment of direct vibration. Except expert service staff, do not disassemble or fix or modify the product. Use the PLC in an environment that meets the general specifications contained in this datasheet. Be sure that external load does not exceed the rating of output module. When disposing of PLC and battery, treat it as industrial waste. 2 Operating Environment To install, observe the below conditions. No Item Specification Standard 1 Ambient temp. 0 ~ 55 - 2 Storage temp. -25 ~ 70 - 3 Ambient humidity 5 ~ 95%RH, non-condensing - 4 Storage humidity 5 ~ 95%RH, non-condensing - Occasional vibration - - Frequency Acceleration Amplitude 5f<8.4 - 3.5mm 5 Vibration Resistance 8.4f150 9.8(1g) - Continuous vibration Frequency Acceleration Amplitude 5f<8.4 - 1.75mm 8.4f150 4.9(0.5g) - 10 times in each direction IEC 61131-2 for X, Y, Z 3 Applicable Support Software For system configuration, the following version is necessary. 1) XGI CPU : V2.1 or above 2) XGK CPU : V3.0 or above 3) XGR CPU : V1.3 or above 4) XG5000 Software : V3.1 or above 4 Parts Name and Dimension (mm) This is front part of the CPU. Refer to each name when driving the system. For more information, refer to user manual. 5 Installing / Removing Modules Here describes the method to attach each product to the base or remove it. 1) Installing module Slide the upper part of module to fix to the base, and then fit it to the base by using the module fixed screw. Pull the upper part of module to check if it is installed to the base completely. 2) Removing module Loosen the fixed screws of the upper part of module from the base. Hold the module by both hands and press the fixed hook of module thoroughly. By pressing the hook, pull the upper part of module from the axis of the lower part of module. By lifting the module upward, remove the fixed projection of module from the fixing hole. 6 Performance Specifications Item Analog input/output range Resolution Precision Input DC 1~5V DC 0~5V DC 0~10V DC 4~20mA DC -10~10V 1/8,000 ±0.2% or less(25) ±0.3% or less(0~55) Output DC 1~5V DC 0~5V DC 0~10V DC 4~20mA DC -10~10V 1/8,000 ±0.2% or less(25) ±0.3% or less(0~55) 7 Wiring Precaution for wiring 1) Don't let AC power line near to analog module's external input/output signal line. With an enough distance kept away between, it will be free from surge or inductive noise. 2) Cable shall be selected in due consideration of ambient temperature and allowable current. More than AWG22 (0.3) is recommended. 3) Don't let the cable too close to hot device and material or in direct contact with oil for long, which will cause damage or abnormal operation due to short-circuit. 4) Check the polarity when wiring the terminal. 5) Wiring with high-voltage line or power line may produce inductive hindrance causing abnormal operation or defect. Wiring examples 1) Voltage input CH0 + - IN0 V0+ IN0 I0+ IN0 COM0 R R R CH3 + - 2) Current input CH0 + - IN3 V3+ IN3 I3+ IN3 COM3 R R R IN0 V0+ IN0 I0+ IN0 COM0 R R R CH3 + - 3) Voltage output IN3 V3+ IN3 I3+ IN3 COM3 R R R Output circuit 4) Current output OUT0_V0+ OUT0_I0+ OUT0_COM0 OUT1_V1+ OUT1_I1+ OUT1_COM1 CH0 CH1 + Actuator 1K ~ 1M - Actuator + 1K ~ 1M - Output circuit OUT0_V0+ OUT0_I0+ OUT0_COM0 OUT1_V1+ OUT1_I1+ OUT1_COM1 CH0 CH1 + Actuator 600 or less - Actuator + 600 or less - Use a 2-core twisted shielded wire. The Input resistance voltage input is 250(typ.). The Input resistance current input is 1(min.). 8 Warranty Warranty period: 18 months after the production date. Scope of Warranty: 18-month warranty is available except: 1) The troubles caused by improper condition, environment or treatment except the instructions of LS ELCECTIC. 2) The troubles caused by external devices 3) The troubles caused by remodeling or repairing based on the user's own discretion. 4) The troubles caused by improper usage of the product 5) The troubles caused by the reason which exceeded the expectation from science and technology level when LS ELECTRIC manufactured the product 6) The troubles caused by natural disaster Change in specifications Product specifications are subject to change without notice due to continuous product development and improvement. LS ELECTRIC Co., Ltd. www.ls-electric.com 10310000984 V4.4 (2021.11) E-mail: automation@ls-electric.com Headquarter/Seoul Office LS ELECTRIC Shanghai Office (China) LS ELECTRIC (Wuxi) Co., Ltd. (Wuxi, China) LS-ELECTRIC Vietnam Co., Ltd. (Hanoi, Vietnam) LS ELECTRIC Middle East FZE (Dubai, U.A.E.) LS ELECTRIC Europe B.V. (Hoofddorf, Netherlands) LS ELECTRIC Japan Co., Ltd. (Tokyo, Japan) LS ELECTRIC America Inc. (Chicago, USA) Tel: 82-2-2034-4033,4888,4703 Tel: 86-21-5237-9977 Tel: 86-510-6851-6666 Tel: 84-93-631-4099 Tel: 971-4-886-5360 Tel: 31-20-654-1424 Tel: 81-3-6268-8241 Tel: 1-800-891-2941 Factory: 56, Samseong 4-gil, Mokcheon-eup, Dongnam-gu, Cheonan-si, Chungcheongnamdo, 31226, Korea