User Guide for Milesight models including: EM300-TH, Temperature and Humidity Sensor Milesight, EM300-TH Temperature and Humidity Sensor Milesight, Humidity Sensor Milesight, Sensor Milesight, Milesight

来一打AD钙奶

Manual

EM300-TH Temperature & Humidity Sensor Milesight | USA


File Info : application/pdf, 18 Pages, 1,014.08KB

PDF preview unavailable. Download the PDF instead.

EM300-Series-User-Guide-V2.3
Environment Monitoring Sensor
Featuring LoRaWAN®
EM300 Series
User Guide

Applicability
This guide is applicable to EM300 series sensors shown as follows, except where otherwise indicated.

Model

Description

EM300-TH

Temperature and Humidity Sensor

EM300-MCS

Magnet Switch Sensor

EM300-SLD

Spot Leak Detection Sensor

EM300-ZLD

Zone Leak Detection Sensor

Safety Precautions
Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide.  The device must not be disassembled or remodeled in any way.  In order to protect the security of the device, please change device password when first
configuration. The default password is 123456.  The device is not intended to be used as a reference sensor, and Milesight will not should
responsibility for any damage which may result from inaccurate readings.  Do not place the device close to objects with naked flames.  Do not place the device where the temperature is below/above the operating range.  Make sure electronic components do not drop out of the enclosure while opening.  When installing the battery, please install it accurately, and do not install the reverse or
wrong model.  Make sure both batteries are newest when install, or battery life will be reduced.  The device must never be subjected to shocks or impacts.

Declaration of Conformity
EM300 series is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.

Copyright © 2011-2022 Milesight. All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user guide by any means without written authorization from Xiamen Milesight IoT Co., Ltd.

2

Revision History
Date Oct. 14, 2020 Oct. 21, 2020 Nov. 19, 2020 Mar. 4, 2021 July 5, 2021 Dec. 7, 2021

For assistance, please contact Milesight technical support: Email: iot.support@milesight.com Tel: 86-592-5085280 Fax: 86-592-5023065 Address: Building C09, Software Park III,
Xiamen 361024, China

Doc Version V 1.0 V 1.1 V 2.0 V 2.1 V 2.2 V 2.3

Description Initial version Model name change and pictures replace Layout replace Layout update Delete USB Type-C description Add alarm setting, change SN to 16 digits

3

Contents
1. Product Introduction................................................................................................................................. 5 1.1 Overview........................................................................................................................................... 5 1.2 Features............................................................................................................................................5
2. Hardware Introduction..............................................................................................................................5 2.1 Packing List......................................................................................................................................5 2.2 Hardware Overview.........................................................................................................................6 2.3 Dimensions...................................................................................................................................... 6 2.4 Power Button................................................................................................................................... 6
3. Operation Guide.........................................................................................................................................7 3.1 NFC Configuration.......................................................................................................................... 7 3.2 LoRaWAN Settings..........................................................................................................................8 3.3 Basic Settings................................................................................................................................11 3.4 Advanced Settings........................................................................................................................11 3.4.1 Calibration Settings...........................................................................................................11 3.4.2 Threshold Settings............................................................................................................ 11 3.4.3 Alarm Settings....................................................................................................................12 3.5 Maintenance.................................................................................................................................. 12 3.5.1 Upgrade............................................................................................................................... 12 3.5.2 Backup.................................................................................................................................13 3.5.3 Reset to Factory Default...................................................................................................14
4. Installation................................................................................................................................................14 5. Milesight IoT Cloud Management........................................................................................................ 15 6. Device Payload........................................................................................................................................ 16
6.1 Basic Information..........................................................................................................................17 6.2 Sensor Data....................................................................................................................................17 6.3 Downlink Commands................................................................................................................... 18
4

1. Product Introduction
1.1 Overview
EM300 series is a sensor mainly used for outdoor environment through wireless LoRa network. EM300 device is battery powered and designed for multiple mounting ways. It is equipped with NFC (Near Field Communication) and can easily be configured by a smartphone.
Sensor data are transmitted in real-time using standard LoRaWAN® protocol. LoRaWAN® enables encrypted radio transmissions over long distance while consuming very little power. The user can obtain sensor data and view the trend of data change through Milesight IoT Cloud or through the user's own Network Server.
1.2 Features
 Up to 11 km communication range  Easy configuration via NFC  Standard LoRaWAN® support  Milesight IoT Cloud compliant  Low power consumption with 4000mAh replaceable battery
2. Hardware Introduction 2.1 Packing List

1 × EM300 Sensor

Wall Mounting Kits

1× Warranty Card

1× Quick Guide

Double Sided Tape(for Mounting Screws (for SLD or MCS sensor) SLD or MCS sensor) If any of the above items is missing or damaged, please contact your sales representative.
5

2.2 Hardware Overview
Front View: NFC Area
Bottom View:  Vent  Waterproof Connectors (For water leakage and magnet switch sensor)
2.3 Dimensions(mm)

2.4 Power Button

Note: The LED indicator and power button are inside the device. Switch on/off and reset can also be configured via NFC.

Function Turn On

Action Press and hold the button for more than 3 seconds.

LED Indication Off  On

Turn Off

Press and hold the button for more than 3 seconds. On -> Off

Reset

Press and hold the button for more than 10 seconds. Blink 3 times.

6

Check Quickly press the power button.
On/Off Status

Light On: Device is on. Light Off: Device is off.

3. Operation Guide
3.1 NFC Configuration
EM300 series can be configured via NFC. 1. Download and install "Milesight ToolBox" App from Google Play or Apple Store. 2. Enable NFC on the smartphone and open"Milesight ToolBox" App. 3. Attach the smartphone with NFC area to the device to read basic information.

4. Basic information and settings of devices will be shown on ToolBox if it's recognized successfully. You can turn on/off the device by tapping the button on the Device Status. In order to protect the security of devices, password validation is required when configuring via unused phone . Default password is 123456.
5. Tap "Read" button to check current status and sensor data of device. 6. Tap "Write" button to write all your settings to the device.
7

Note: 1) Ensure the location of smartphone NFC area and it's recommended to take off phone case. 2) If the smartphone fails to read/write configurations via NFC, keep the phone away and back to try again. 3) EM300 series can also be configured by dedicated NFC reader provided by Milesight IoT or you can configure it via TTL interface inside the device.
3.2 LoRaWAN Settings
LoRaWAN settings is used for configuring the transmission parameters in LoRaWAN® network.
Basic LoRaWAN Settings:
Go to Device->Setting->LoRaWAN Settings of ToolBox App to configure join type, App EUI, App Key and other information. You can also keep all settings by default.
8

Parameters Device EUI
App EUI Application Port
Join Type Application Key Device Address Network Session
Key Application Session Key Spread Factor Confirmed Mode
Rejoin Mode
ADR Mode Tx Power

Description Unique ID of the device which can also be found on the label. Default App EUI is 24E124C0002A0001. The port used for sending and receiving data, default port is 85. OTAA and ABP mode are available. Appkey for OTAA mode, default is 5572404C696E6B4C6F52613230313823. DevAddr for ABP mode, default is the 5th to 12th digits of SN.
Nwkskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
Appskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
If ADR is disabled, the device will send data via this spread factor. If the device does not receive ACK packet from network server, it will resend data 3 times at most. Reporting interval  30 mins: device will send specific mounts of LoRaMAC packets to check connection status every 30 mins; If no reply after specific packets, the device will re-join. Reporting interval > 30 mins: device will send specific mounts of LoRaMAC packets every to check connection status every reporting interval; If no reply after specific packets, the device will re-join. Allow network server to adjust datarate of the device. Transmit power of device.

Note: 1) Please contact sales for device EUI list if there are many units. 2) Please contact sales if you need random App keys before purchase. 3) Select OTAA mode if you use Milesight IoT cloud to manage devices. 4) Only OTAA mode supports rejoin mode.
LoRaWAN Frequency Settings:
Go to Setting->LoRaWAN Settings of ToolBox App to select supported frequency and select channels to send uplinks. Make sure the channels match the LoRaWAN® gateway.

9

If frequency is one of CN470/AU915/US915, you can enter the index of the channel that you want to enable in the input box, making them separated by commas. Examples: 1, 40: Enabling Channel 1 and Channel 40 1-40: Enabling Channel 1 to Channel 40 1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60 All: Enabling all channels Null: Indicates that all channels are disabled
Note: For -868M model, default frequency is EU868; For -915M model, default frequency is AU915.
10

3.3 Basic Settings
Go to "Device->Setting->General Settings" of ToolBox App to change the reporting interval, etc.

Parameters Reporting Interval Temperature Unit
Change Password

Description Reporting interval of transmitting data to network server.Default: 600s Change the temperature unit displayed on the ToolBox. Note: 1) The temperature unit in the reporting package is fixed as °C. 2) Please modify the threshold settings if the unit is changed. Change the password for ToolBox App or software to read/write this device.

3.4 Advanced Settings
3.4.1 Calibration Settings
ToolBox supports numerical calibration for all items. Go to "Device->Setting->Calibration Settings" of ToolBox App to type the calibration value and save, the device will add the calibration value to raw value.

3.4.2 Threshold Settings
Go to Device->Setting->Threshold Settings of ToolBox App to enable the threshold settings and
11

input the threshold. EM300 series will upload the current data once instantly after the temperature threshold is triggered.
3.4.3 Alarm Settings
Go to "Device->Setting->Alarm Settings" of ToolBox App to enable the alarm settings. When EM300 detects door status change or water leakage, it will report the alarm according to reporting interval and reporting times setting.
3.5 Maintenance
3.5.1 Upgrade
1. Download firmware from Milesight website to your smartphone. 2. Open Toolbox App and click "Browse" to import firmware and upgrade the device. Note: 1) Operation on ToolBox is not supported during an upgrade. 2) Only Android version ToolBox supports the upgrade feature.
12

3.5.2 Backup
EM300 devices support configuration backup for easy and quick device configuration in bulk. Backup is allowed only for devices with the same model and LoRa frequency band. 1. Go to "Template" page on the App and save current settings as a template. You can also edit the template file. 2. Select one template file which saved in the smartphone and click "Write", then attach to another device to write configuration.
Note: Slide the template item left to edit or delete the template. Click the template to edit the configurations.
13

3.5.3 Reset to Factory Default
Please select one of following methods to reset device: Via Hardware: Hold on power button (internal) for more than 10s. Via ToolBox App: Go to "Device->Maintenance" to click "Reset", then attach smart phone with NFC area to device to complete reset.
4. Installation
1. Attach EM300 to the wall and mark the two holes on the wall. The connecting line of two holes must be a horizontal line.
14

2. Drill the holes according to the marks and screw the wall plugs into the wall. 3. Mount the EM300 to the wall via mounting screws. 4. Cover the mounting screws with screw caps.
5. For leak detection senor, install the probe/cable to the place where liquid may leak. For magn et switch sensor, install the magnet beside the door/window. Note: For SLD sensor, please ensure the metal pins of the probe are flat on the floor; for ZLD sensor, the cable can't be twined or accumulated together. The probe or cable of water leakage sensor should be placed in an area of concern where water from a leak would likely accumulate.
5. Milesight IoT Cloud Management
EM300 series can be managed by Milesight IoT Cloud platform. Milesight IoT cloud is a comprehensive platform that provides multiple services including device remote management and data visualization with the easiest operation procedures. Please register a Milesight IoT Cloud account before operating following steps. 1. Ensure Milesight LoRaWAN® gateway is online in Milesight IoT Cloud. For more info about connecting gateway to cloud please refer to gateway's user guide.
15

2. Go to "My Devices" page and click "+New Devices". Fill in the SN of device and select associated gateway.
3. After the device is online in Milesight IoT Cloud, you can check the data via webpage or mobile App and create dashboard for it.

6. Device Payload

All data are based on following format(HEX):

Channel1 Type1 Data1 Channel2 Type2 Data2 Channel 3 ...

1 Byte 1 Byte N Bytes 1 Byte 1 Byte M Bytes 1 Byte

...

For decoder examples please find files on https://github.com/Milesight-IoT/SensorDecoders.

16

6.1 Basic Information
EM300 series sensors report basic information of sensor whenever joining the network.

Channel

Type

Description

01(Protocol Version) 01=>V1

09 (Hardware Version) 01 40 => V1.4

ff

0a(Software Version) 01 14 => V1.14

0f(Device Type) 16(Device SN)

00: Class A, 01: Class B, 02: Class C 16 digits

Example:

Channel ff
Channel ff

Type 09
(Hardware version) Type 0f (Device Type)

ff 09 01 00 ff 0a 01 02 ff 0f 00

Value

Channel

Type

0100 (V1.0)

ff

0a (Software version)

Value

00 (Class A)

Value
0102 (V1.2)

6.2 Sensor Data
EM300 series sensors report sensor data according to reporting interval (10min by default). Battery level is reported every 6 hours.

Channel 01 03 04 05
06

Type 75(Battery Level) 67 (Temperature)
68(Humidity) 00(Water Leakage
Status)
00(Magnet Status)

Description UINT8, Unit: % INT16, Unit: °C INT8, Unit: % 00: Not water leakage 01: Water leakage
00: Magnet switch closed 01: Magnet switch open

Example:

Channel

Type

01 75 64 03 67 10 01 04 68 71 05 00 01

Value

Channel

Type

Value

17

01 Channel
04

75 (Battery)
Type
68 (Humidity)

64 => 100%
Value 71=>113 Hum=113* 0.5=56.5%

03 Channel
05

67 (Temperat
ure) Type
00

10 01 => 01 10 = 272 Temp=272*0.1=27.2°C
Value
01=>Water leakage

6.3 Downlink Commands
EM300 series sensors support downlink commands to configure the device. The application port is 85 by default.

Channel ff

Type 03 (Set Reporting Interval)

Description 2 Bytes, unit: s

Example: Set reporting interval as 20 minutes.

Channel ff

ff03b004

Type 03 (Set Reporting
Interval)

Value b0 04 => 04 b0 = 1200s
= 20 minutes

-END-

18



References

WPS 文字