Kidde 230V Mains Carbon Monoxide Alarms with Rechargeable Battery Back-up – User Guide

Models: 4MCO, 4MDCO

Contents

  1. Diagram of Alarms
  2. What is Carbon Monoxide?
  3. Safety Information
  4. Installation Instructions – Recommended Locations
  5. Using Your Alarm-what the signals mean
  6. Mains Power Failure
  7. Interconnected systems
  8. What to do if Your Alarm Sounds!
  9. Maintenance of Your Alarm
  10. Troubleshooting
  11. Product Specifications
  12. Warnings and Important Notices
  13. Warranty
  14. Environmental Protection

1. Diagram of Alarms

Model 4MCO:

Model 4MDCO:

2. What is Carbon Monoxide?

Carbon monoxide (CO) is a highly poisonous gas with no taste, colour or smell.

Potential Sources of CO

This CO alarm is not a substitute for the correct maintenance of your appliances.

Carbon monoxide can be produced from poorly burning appliances or from blocked flues and chimneys.

If your alarm has sounded and you have ventilated the room the CO may have dispersed before help arrives. It is crucial that the source of CO is determined and appropriate maintenance carried out.

Carbon monoxide is a cumulative poison. Longterm exposure to low levels may cause symptoms. This Kidde alarm is time-weighted – the higher the level of CO, the sooner it will alarm.

NOTE: The apparatus may respond to brief exhaust gas emissions, for example during the initial start-up of an appliance. Also, hydrogen acts as an interferent and can arise from some battery charging activities and the curing of concrete or cement under certain circumstances. Volatile Organic Compounds (VOCs), e.g. alcohols, which may eventually activate the alarm, can be generated from use of damp-proofing materials or other coatings containing alkylalkoxysilanes.

3. Safety Information

To be safe, know the possible sources of CO in your home. Keep fuel burning appliances and their chimneys and vents in good working condition. Learn the early symptoms of exposure, and if you suspect CO poisoning, move outside to fresh air and get emergency help. Your first line of defence is an annual inspection and regular maintenance of your appliances. Contact a licensed contractor or call your local utility company for assistance.

In rented properties your Landlord (or Council/ Housing Association), will have an Emergency Response phone number, and be liable for the regular maintenance of their combustion appliances (Gas/LPG/Oil/Solid Fuel).

This alarm has not been tested specifically for use in caravans or boats. Only CO alarms certified to EN50291-2 are fully approved for this purpose.

Alarm levels as defined by EN50291-1:2010

Parts per Million (PPM) of CO Time until Alarm
50 60 – 90 minutes
100 10 – 40 minutes
300 Must alarm in less than 3 minutes

CO Advice and Information

The table below shows the effects of different levels of CO poisoning on the body;

Parts per Million (PPM) Effects on Adults
100 Slight headache, nausea, fatigue (flu-like symptoms)
200 Dizziness and headache within 2 – 3 hours
400 Nausea, frontal headache, drowsiness, confusion and rapid heart rate. Risk to life after over 3 hours of exposure
800 Severe headaches, convulsions, vital organ failures. Death possible within 2 – 3 hours

3. Important Safety Information

NOTE: If you recognise any of the above symptoms consult your Doctor immediately.

NOTE: Young children, elderly and pets are more susceptible to the dangers of CO.

NOTE: Your Kidde alarm is designed to detect CO gas. It is not designed to detect smoke, fire or other gas such as natural gas.

NOTE: This product is intended for use in ordinary family homes. It is not designed to measure compliance with occupational safety and the HSE.

NOTE: Individuals with certain specific medical conditions may need an alarm that operates below 30ppm. If this applies consult your Doctor.

IMPORTANT: Ensure that all family members are familiar with the symptoms of CO poisoning and how your alarm works.

4. Installation Instructions – Recommended Locations

Locations to Avoid

4. Installation Instructions –Supply and Interconnect

Refer to Separate Easy Installation Instructions

NOTE: THIS ALARM IS DESIGNED FOR INSTALLATION BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE LATEST IEE REGULATIONS AND RELEVANT BRITISH STANDARDS.

THIS ALARM MUST BE POWERED BY A CONSTANT 230V AC, 50Hz SUPPLY THAT IS NOT CONTROLLED BY ANY FORM OF SWITCH.

THIS ALARM INTERCONNECTS WITH UP TO 24 KIDDE DEVICES (OF WHICH 18 CAN BE INITIATING) INCLUDING SMOKE, CO AND HEAT ALARMS. (SEE BELOW)

THIS ALARM IS NOT DESIGNED TO BE INTERCONNECTED WITH OTHER MANUFACTURER'S PRODUCTS, UNLESS OTHERWISE SPECIFIED.

Firex Kidde
KF10R 1SFWR Mains Ionisation Alarm with Rechargeable battery back-up
KF10 1SFW Mains Ionisation Alarm with alkaline battery back up
KF20R 2SFWR Mains Optical Alarm with Rechargeable battery back-up
KF20 2SFW Mains Optical Alarm with alkaline battery back up
KF30R 3SFWR Mains Heat Alarm with Rechargeable battery back-up
KF30 3SFW Mains Heat Alarm with alkaline battery back up
4MCO Mains CO Alarm with rechargeable battery back-up
4MDCO Mains CO Alarm with rechargeable battery back-up, digital display

5. Using Your Digital Alarm (4MDCO) – what the signals mean

LEDS LCD Sounder Unit Status Action
Normal Operation Red None Normal Operation None
Alarm Amber Red Flashing Displays CO ppm (30-999) 4 loud beeps/pause/4 loud beeps- repeated CO detected See section
Interconnected CO alarm detects CO Amber Red Flashing CO. 4 loud beeps/pause/4 loud beeps- repeated Interconnected CO alarm detects CO See section
Interconnected Heat/Smoke alarm detects hazard Amber Red Flashing FirE. 3 loud beeps/pause/3 loud beeps- repeated Smoke or heat has been detected from an interconnected smoke or heat alarm EVACUATE THE PREMISES ACCORDING TO YOUR ESCAPE PLAN
Error condition -1 Red Flashing every 30 secs Err. Chirp/30 secs Unit has failed Replace
Error condition -2 Amber Flashing every 30 secs Constant loud sound Unit microprocessor has failed Replace
End of Life Red ON Err. Chirp twice every 30 seconds The unit has reached the end of its life Replace
Charging the battery back up Amber Flashing twice every 30 secs NONE Battery backup is charging (unit is monitoring for CO) Nothing
Low battery Red Flashing every 15 secs Lb Flashes Chirp / 15 secs Back up battery is discharged Ensure switch is On at the rear of the unit - if it persists contact Kidde
Amber Flashing every 15 secs
Red Flashing every 15 secs
Amber Flashing every 15 secs

NOTE: If AC mains is connected and active, the Green LED will be on continuous. If Green LED is not on, see Section 6.

5. Using Your Non-Digital Alarm (4MCO) – what the signals mean

LEDS Sounder Unit Status Action
Normal Operation Red None Normal Operation None
Alarm Amber Red Flashing 4 loud beeps/pause/4 loud beeps- repeated CO detected See section
Interconnected CO alarm detects CO Red Amber Flashing 4 loud beeps/pause/4 loud beeps- repeated Interconnected CO alarm detects CO See section
Interconnected Heat/Smoke alarm detects hazard Red Amber Flashing 3 loud beeps/pause/3 loud beeps- repeated Smoke or heat has been detected from an interconnected smoke or heat alarm EVACUATE THE PREMISES ACCORDING TO YOUR ESCAPE PLAN
Error condition -1 Red Amber Flashing every 30 secs Chirp/30 secs Unit has failed Replace
Error condition -2 Red ON Constant loud sound Unit microprocessor has failed Replace
End of Life Amber Red Flashing Chirp twice every 30 seconds The unit has reached the end of its life Replace
Charging the battery back up Amber Flashing twice every 30 secs NONE Battery backup is charging (unit is monitoring for CO) Nothing
Low battery Red Amber Flashing every 15 secs Chirp / 15 secs Back up battery is discharged Ensure switch is On at the rear of the unit - if it persists contact Kidde
Red Flashing every 15 secs
Amber Flashing every 15 secs

NOTE: If AC mains is connected and active, the Green LED will be on continuous. If Green LED is not on, see Section 6.

5. Using Your Alarm – Cont.

Testing

Each week your alarm should be tested by pressing the test button. The alarm will beep once followed by a brief pause. Then the alarm will sound fully with 4 beeps a pause and then 4 beeps.

During testing the red LED will flash.

The Digital model will display "888" followed by a 200+ number.

This confirms that the alarm is powered up and working.

Re-setting the Alarm

If the alarm sounds, the test / reset button will silence the alarm unless it is still detecting dangerous levels of CO.

Peak Level Memory – Digital model only

Pressing the Peak level memory button tells you if you have had levels of CO>9ppm. To reset keep the peak level button pressed and press the test button for 2 seconds.

End of Life Notification

After 7 years of continuous operation, the unit will chirp twice every 30 seconds, and the amber LED will flash twice. The red LED will also be flashing. Unit has reached end of life, and must be replaced.

NOTE: Constant exposures to extreme temperatures and humidities may affect battery life.

6. Mains Power Failure – Digital Alarm (4MDCO)

LEDS LCD Sounder Unit status Action
Loss of Mains power Red OFF 0 or CO ppm displayed every 60 secs Unit has no mains power and the battery back up will have limited life Restore the mains ASAP
Green Flashing every 7 secs
Amber OFF
Low Battery when mains has failed Red Flashing every 15 secs Lb and 0 or CO ppm alternate only for the first 5 minutes Chirp/15 secs Back up battery is discharged Restore the mains ASAP
Green Flashing every 7 secs
Amber Flashing every 15 secs
Battery back up close to discharge Red Flashing every 60 secs None Chirp/60 secs Unit will no longer detect CO Restore the mains ASAP
Green Flashing every 7 secs
Amber OFF

6. Mains Power Failure – Non Digital Alarm (4MCO)

LEDS Sounder Unit status Action
Loss of Mains power Red OFF Unit has no mains power and the battery back up will have limited life Restore the mains ASAP
Green Flashing every 7 secs
Amber OFF
Low Battery when mains has failed Red Flashing every 15 secs Chirp/15 secs Back up battery is discharged Restore the mains ASAP
Green Flashing every 7 secs
Amber Flashing every 15 secs
Battery back up close to discharge Red Flashing every 60 secs Chirp/60 secs Unit will no longer detect CO Restore the mains ASAP
Green Flashing every 7 secs
Amber OFF

7. Interconnected systems

Interconnected systems of Kidde Models - 1SFW, 1SFWR, 2SFW, 2SFWR, 3SFW, 3SFWR, 4MCO, 4MDCO

CO Alarm Smoke/Heat Alarm
Press CO test button Normal test sequence - 4 loud beeps pause and then 4 loud beeps and so on. Do not sound
Press Smoke/Heat Alarm test button 3 loud beeps pause 3 beeps with Red LED flashing 3 loud beeps pause 3 loud beeps with Red LED flashing
Smoke/Heat Alarm Event 3 loud beeps pause 3 loud beeps with Red flashing. The Digital model will display " Fire" 3 loud beeps pause 3 loud beeps with Red flashing.
CO event Alarms with 4 loud beeps pause 4 beeps and so on Do not sound

Smokes/Heat alarm will override CO

Interconnected systems of Firex models, KF10, KF10R, KF20, KF20R, KF30, KF30R

CO Alarm Smoke/Heat Alarm
Press CO test button Normal test sequence - 4 loud beeps pause and then 4 loud beeps and so on. Normal test sequence - 4 loud beeps pause and then 4 loud beeps and so on.
Press Smoke/Heat Alarm test button 3 loud beeps pause 3 beeps with Red LED flashing 3 loud beeps pause 3 loud beeps with Red LED flashing
Smoke/Heat Alarm Event 3 loud beeps pause 3 loud beeps with Red flashing. The Digital model will display " Fire". 3 loud beeps pause 3 loud beeps with Red flashing.
CO event Alarms with 4 loud beeps pause 4 beeps and so on. Alarms with 4 loud beeps pause 4 beeps and so on.

Smokes/Heat alarm will override CO

8. What to do if Your Alarm Sounds!

Carbon Monoxide Alarm Procedure

WARNING! Activation of the alarm indicates the presence of Carbon Monoxide (CO) which can kill you.

Based on recommendations from EN 50292, follow these steps if alarm sounds (4 loud audible pulses followed by a pause for 5 seconds):

  1. Keep calm and open all doors and windows. Turn off all fuel-burning appliances if possible. Note: it is possible that outdoor conditions could influence domestic CO alarms (bad traffic pollution in cold weather, for example). In these circumstances, the level of indoor CO might actually increase when doors and windows are opened.
  2. If the alarm continues to sound, even after being reset (where appropriate), then evacuate the premises, alerting other occupants to the risk. Leave doors and windows open. Do not re-enter the premises.
  3. Get medical help for anyone suffering the effects of CO poisoning, and advise that CO inhalation is suspected.
  4. Call Gas Emergency Services: 0800 111 999, or your local Gas Safe Registered Engineer:

PHONE NUMBER:

Never restart the source of the CO problem until it has been corrected. Never ignore the sound of the alarm! If the alarm is sounding, pressing the test/reset button will terminate the alarm. If the CO condition that caused the alert in the first place continues, the alarm will reactivate. If the unit alarms again within six minutes, it is sensing high levels of CO which can quickly become a dangerous situation.

9. Maintenance of Your Alarm

This is a Mains Alarm. Isolate before removing for decorating. If in doubt contact a qualified electrician.

Warning: Do not tamper with the apparatus, as there is a risk of electric shock or malfunction.

To keep your alarm in good working order:

The following substances can affect the sensor and cause false alarms:

Methane, Propane, Iso-butane, Iso-propanol, Ethylene, Benzene, Toluene, Ethyl acetate, Hydrogen Sulphide, Hydrogen, Sulphur Dioxide, alcohol based products, paints, thinners, solvents, adhesives, hair-sprays, aftershaves or perfumes and some cleaning agents.

NOTE: there could be other compounds occurring within a particular household which could cause similar effects.

10. Troubleshooting

LEDS LCD (4MDCO) Sounder Unit Status Action
Error condition -1 Red Flashing every 30 secs Err. Chirp/30 secs Unit has failed Replace
Amber Flashing every 30 secs
Error condition -2 Red ON Constant loud sound Unit microprocessor has failed Replace
Amber
End of Life Red Flashing Err. Chirp twice every 30 seconds The unit has reached the end of its life Replace
Amber Flashing twice every 30 secs
Low battery Red Flashing every 15 secs NONE Chirp/15 secs Backup battery is discharged Ensure switch is ON at the rear of the unit-if it persists, contact Kidde
Amber Flashing every 15 secs

NOTE: If AC mains is connected and active, the Green LED will be on continuous. If Green LED is not on, see Section 6.

11. Product Specifications

Power 240V, 50Hz 30mA max
Sensor Electrochemical CO Sensor
Storage and Transport Conditions -20 °C to +60°C, 5 - 95% RH (no condensing)
Temperature Range Operating range: 0°C to 40°C
Humidity up to 90% relative humidity (RH), non-condensing
Alarm Sound 85db+ at 10' (3 metres) @ 3.4 +/- 0.5 KHz pulsing alarm
Size and weight Weight: 220g Dimensions: 145mm x145mm x 40mm

12. Warnings and Important Notices

WARNING: THIS CARBON MONOXIDE ALARM IS NOT A SUBSTITUTE FOR INSTALLING AND MAINTAINING AN APPROPRIATE NUMBER OF SMOKE ALARMS IN YOUR HOME. THIS ALARM WILL NOT SENSE SMOKE, FIRE, OR ANY POISONOUS GAS OTHER THAN CARBON MONOXIDE. FOR THIS REASON YOU MUST INSTALL SMOKE ALARMS TO PROVIDE EARLY WARNING OF FIRE AND TO PROTECT YOU AND YOUR FAMILY FROM FIRE AND ITS RELATED HAZARDS.

WARNING: THIS PRODUCT IS INTENDED FOR USE IN ORDINARY INDOOR RESIDENTIAL AREAS. IT IS NOT DESIGNED TO MEASURE COMPLIANCE WITH COMMERCIAL AND INDUSTRIAL STANDARDS. THIS ALARM IS NOT SUITABLE FOR INSTALLATION IN HAZARDOUS LOCATIONS. INDIVIDUALS WITH MEDICAL PROBLEMS MAY CONSIDER USING WARNING DEVICES WHICH PROVIDE AUDIBLE AND VISUAL SIGNALS FOR CARBON MONOXIDE CONCENTRATIONS UNDER 30 PPM.

IMPORTANT: THIS CARBON MONOXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE FROM ANY SOURCE OF COMBUSTION INCLUDING IMPROPER OR MALFUNCTIONING APPLIANCES. THE INSTALLATION OF THIS DEVICE SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION, USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS

WARNING: THIS ALARM WILL NOT WORK WITHOUT POWER. THIS ALARM REQUIRES A CONTINUOUS SUPPLY OF POWER.

WARNING: THIS UNIT IS NOT A SMOKE ALARM. IT WILL NOT SENSE SMOKE. FOR EARLY WARNING OF FIRE YOU MUST INSTALL SMOKE ALARMS.

IMPORTANT: IF ANY FAULT SIGNALS OCCUR, CONTACT THE MANUFACTURER OR SUPPLIER AND DO NOT CONTINUE USING THE ALARM.

WARNING: THE DEVICE CANNOT WARN AGAINST THE CHRONIC EFFECTS OF EXPOSURE TO CARBON MONOXIDE OR PROTECT INDIVIDUALS WHO ARE AT SPECIFIC RISK.

WARNING: ALTERING THE ALARM IN ANY WAY MAY LEAD TO A RISK OF ELECTRIC SHOCK OR PREVENT IT FROM FUNCTIONING CORRECTLY.

CAUTION: THIS ALARM WILL ONLY INDICATE THE PRESENCE OF CARBON MONOXIDE AT THE SENSOR. CARBON MONOXIDE MAY BE PRESENT IN OTHER AREAS.

13. Warranty

SEVEN YEAR LIMITED WARRANTY

WARRANTY COVERAGE: THE MANUFACTURER WARRANTS TO THE ORIGINAL CONSUMER PURCHASER, THAT THIS PRODUCT WILL BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF SEVEN (7) YEARS FROM DATE OF PURCHASE. THE MANUFACTURER'S LIABILITY HEREUNDER IS LIMITED TO REPLACEMENT OF THE PRODUCT. REPAIR OF THE PRODUCT OR REPLACEMENT OF THE PRODUCT WITH REPAIRED PRODUCT AT THE DISCRETION OF THE MANUFACTURER. THIS WARRANTY IS VOID IF THE PRODUCT HAS BEEN DAMAGED BY ACCIDENT, UNREASONABLE USE, NEGLECT, TAMPERING OR OTHER CAUSES NOT ARISING FROM DEFECTS IN MATERIAL OR WORKMANSHIP. THIS WARRANTY EXTENDS TO THE ORIGINAL CONSUMER PURCHASER OF THE PRODUCT ONLY.

Warranty Disclaimers: Any implied warranties arising out of this sale, including but not limited to the implied warranties of description, merchantability and fitness for a particular purpose, are limited in duration to the above warranty period. In no event shall the Manufacturer be liable for loss of use of this product or for any indirect, special, incidental or consequential damages, or costs, or expenses incurred by the consumer or any other user of this product, whether due to a breach of contract, negligence, strict liability in tort or otherwise. The Manufacturer shall have no liability for any personal injury, property damage or any special, incidental, contingent or consequential damage of any kind resulting from gas leakage, fire or explosion. This warranty does not affect your statutory rights.

Warranty Performance: During the above warranty period, your product will be replaced with a comparable product if the defective product is returned, postage prepaid, to KIDDE Safety Europe Ltd, Mathisen Way, Colnbrook, Slough SL3 OHB. Telephone 01753 685148, together with proof of purchase date. Please include a note describing the problem when you return the unit. The replacement product will be in warranty for the remainder of the original warranty period or for six months, whichever is longer. Other than the cost of postage, no charge will be made for replacement of the defective product. Important: Do not open unit. Opening unit will void warranty.

Your Carbon Monoxide Alarm is not a substitute for property, disability, life or other insurance of any kind. Appropriate insurance coverage is your responsibility. Consult your insurance agent. Kidde makes no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose, with respect of the batteries.

For Warranty Service: In many cases the quickest way to exchange your CO alarm is to return it to the original place of purchase. If you have questions, call the KIDDE customer service department on 01753 685148

14. Environmental Protection

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with Local Authority or retailer for recycling advice.

Useful Contact Information

P/N: 2512-7220-03

PDF preview unavailable. Download the PDF instead.

2883 Kidde-4MCO-4MDCO-Manual QuarkXPress(R) 7.3 QuarkXPress(R) 7.3

Related Documents

Preview Kidde K10LLCO/K10LLDCO Carbon Monoxide Alarm User and Installer Guide
Comprehensive user and installer guide for Kidde K10LLCO and K10LLDCO sealed battery carbon monoxide alarms. Learn about operation, installation, troubleshooting, safety, and maintenance.
Preview Kidde KN-COPP-3 Carbon Monoxide Alarm User's Guide
Comprehensive user guide for the Kidde KN-COPP-3 Carbon Monoxide Alarm, detailing its features, installation, operation, maintenance, and troubleshooting. Learn about carbon monoxide safety and how to respond to alarm events.
Preview Kidde 30CUA10 Combination Smoke and Carbon Monoxide Alarm User Guide
Comprehensive user guide for the Kidde 30CUA10 Combination Photoelectric Smoke and Carbon Monoxide Alarm with Hardwire Interconnect, covering installation, operation, testing, troubleshooting, safety, and warranty information.
Preview Kidde K7CO & K7DCO Battery Carbon Monoxide Alarms User and Installer Guide
Comprehensive user and installer guide for Kidde K7CO and K7DCO battery-powered carbon monoxide alarms, covering installation, operation, troubleshooting, safety, and warranty information.
Preview Kidde Firex CUACFEX Combination Smoke and Carbon Monoxide Alarm User Guide
Comprehensive user guide for the Kidde Firex CUACFEX combination photoelectric smoke and carbon monoxide alarm. Learn about installation, operation, testing, safety features, and troubleshooting for this 120V hardwire interconnect alarm with battery backup.
Preview Kidde KN-COB-DP2 Carbon Monoxide Alarm User Guide
Comprehensive user guide for the Kidde KN-COB-DP2 AC Plug-In Carbon Monoxide Alarm, covering installation, operation, maintenance, and safety information.
Preview Kidde CUACFEX Combination Smoke & Carbon Monoxide Alarm User Guide
User guide for the Kidde CUACFEX Combination Photoelectric Smoke & Carbon Monoxide Alarm with Hardwire Interconnect. Provides installation, operation, troubleshooting, and safety information.
Preview Kidde AC Powered Carbon Monoxide Alarm User's Guide
User's guide for the Kidde AC Powered Carbon Monoxide Alarm, covering installation, operation, maintenance, and safety information. Includes details on model KN-COB-DP-H and KN-COB-LCB-A.