Instruction Manual for ZUBR models including: V1, V1 Single Phase Household Voltmeter, Single Phase Household Voltmeter, Household Voltmeter, Voltmeter
Instructions for terneo and ZUBR devices
Single phase household voltmeter ZUBR V1 | ds-electronics.com.ua
File Info : application/pdf, 2 Pages, 480.64KB
DocumentDocumentVoltmeter for professionals V1 Technical data sheet, installation and operation manual V1 digital single-phase voltmeter (hereinafter referred to as the device) is designed to monitor the voltage ofasingle-phase network. The device stores the maximum and minimum mains voltage in non-volatile memory. Stored values can bereset. IN THE BOX Digital single-phase voltmeter ZUBR V1 Technical data sheet, installation and operation manual and warranty card The packing box 1 piece 1 piece 1 piece TECHNICAL DATA Power Volt Device weight Overall dimensions (w × h × d) Degree of protection GOST14254 Power consumption Connection not less than 100 V not more than 420 V 0,14 kg ±10 % 53 85 66 mm IP20 not more than 1,5 kWt*h / month not more than 16 mm2 CONNECTION SCHEMES Voltage for measurement and supply (100420 V, 50 Hz) isapplied to terminals 1 and 2. PE N L Input KV Voltmeter QFinput 40 ZUBR V1 12 QD 63 A 300 mA L N PE QF1 16 16 Scheme 1. Option of wiring diagram INPUT L N Before the installation and operation ofthedevice, PLEASE READ BY THE END OFTHIS DOCUMENT. This will help to avoid possible danger, mistakes and misunderstandings. NON-VOLATILE VOLTMETER STORAGE saves all settings in the event of a power outage. IT IS FORBIDDEN TO POWER THE DEVICE FROM SOURCES WITH A MODIFIED SINE WAVE, uninterruptible power supplies whose output voltage is not a sine wave. Long operation (more than 5 minutes) from the following sources voltage may damage ZUBR and lead tonot warranty repair. ZUBR V1 ~ V max reset min Scheme 2. Option of the connection diagram 2 INSTALLATION The appliance is intended for installation inside residences. The risk of moisture or humidity in the installation site should be minimal. When installing in the bathroom, toilet, kitchen, pool appliance must be located in a shell with protection degree not below IP55 per GOST 14254 (partial protection from dust and waterproof in any direction). Theambient temperature during installation should bewithin 5...+45 °. The appliance is installed in a special box, which allows toconduct the easy installation and operation. Cabinet should be equipped with standard mounting rail 35 mm width (DIN rail). The appliance takes in width of three standard modules on 18 mm. The height of the appliance should be in the range 0,5...1,7 m from the floor. To connect your device: -- fix the appliance on the mounting rail (DIN); -- take a wire; -- make the connection according to the passport. Necessarily need to set in front oftheappliance, theautomatic circuit-breaker (QF) (see schemes 1, 2). Toprotect person from electric shock leak is set safety shutdown device (QD). Terminals of the device designed for wire cross section upto 16 mm². To reduce mechanical load on the terminals itisdesirable to use soft wire. Clean the end wires of10±0,5mm. If end is longer, it can cause a short circuit, and if short -- cause unreliable connection. Use the cable lugs. Undo the screws of the terminals and insert tipped end of the wire in terminal. Tighten terminal with derived average 2,4 ·m. Low tight may lead to low contact and overheating terminals and wires and over tight -- damage terminals and wires. Wires protracted in terminals with ascrewdriver with a shank width not more than 6 mm. Screw with shank width more than 6 mm may apply mechanical damage to terminals. This could result in loss of warranty. EXPLOITATION When turned on, the voltmeter immediately begins tomeasure and display the value of the mains voltage. Viewing the minimum and maximum voltage To view the maximum voltage stored inthememory, press the top button and toview minimum voltage, press lower button. The display of voltage values isaccompanied by the glow of dots intherightmost category of the screens. Five seconds after the last pressing of the buttons, thevoltmeter will return to displaying the mains voltage. 3 Resetting the stored maximum and minimum voltage A short press on the middle button will display «rSt» on the screen. When thebutton is released, the voltmeter will erase all stored voltage values from memory. Five seconds after the last pressing of the buttons, thevoltmeter will return to displaying the mains voltage. Viewing of firmware version To view the firmware version, hold themiddle button for 12 seconds. WARRANTY TERMS The warranty for ZUBR devices is valid for 60 months from the date of sale, provided that the instructions arefollowed. The warranty period for products without awarranty certificate is counted from the date ofproduction. If your device is not working properly, we recommend that you first read the section «Possible problems». If you cannot find an answer, contact Service Center. In most cases, these actions resolve all issues. If you continue to have issues with the device, please send it to a Service Center or to the store where you purchased the device. If your device is defective due toour fault, we will repair or replace it under warranty within 14 business days. Please see the full text of the warranty and the data you need to send to your Service Center on the website https://www.ds-electronics.company. If you have awarranty case, please, contact the General distributor inyour area. WARRANTY CARD serial : SERVICE CENTER CONTACT +38 (091) 481-91-81 Viber WhatsApp Telegram support@dse.com.ua date of sale: a seller, a seal: an owner contact for a service center: place of a seal Correction of voltage indications on the screen If you think that the readings of the voltmeter V1 and your reference device differ, the readings can be calibrated. To do this, enter the correction menu byholding down the middle button for6seconds until «Cor» appears onthescreen. After releasing the button, you will see ablinking correction value, which can bechanged with the «max» button toincrease or «min» to decrease the value. The range of variation corresponds to±20V. Five seconds after the last pressing, the voltmeter will return to displaying the mains voltage with the adjustment made. POSSIBLE PROBLEMS, CAUSES AND WAYS TO OVERCOME THEM At turning on neither indicator nor screen do not shine Possible cause: There is no power supply voltage. It is necessary to: Ensure supply voltage presence. ADDITIONAL INFORMATION Do not fire and do not throw away the device with thehousehold waste. After the end of its service life, the product must bedisposed of in accordance with applicable law. Transportation of goods carried in the package, ensuring the safety of the product. The deive is transported by any kind of transport (rail, sea, motor, air transportation). Date of manufacture is on the back side of device. Application time is unlimited. The device does not contain harmful substances. If you have any questions or you something will not clear, call the Service centre the telephone number listed below. SAFETY INSTRUCTIONS Carefully read and become aware of yourself these instructions. Connection of the device must be done by a qualified electrician. Before the installation (dismantling) and connection (disconnection) of the device, turn off voltage supply and also act according to the «Rules of an arrangement ofelectric installations». Turning on and off or and configure the device should bewith dry hands. Do not connect the device to the network disassembled. Avoid hitting of water or moisture to the device. Do not expose the device to extreme temperatures (higher than 40 º or below -5 °C) and high humidity. Never clean the device with the use of chemicals such asbenzene, solvents. Do not store the device and do not use it in areas with thedust. Do not attempt to disassemble and repair the device. Do not exceed the landmarks value adaptor and power. To protect against overvoltage caused by lightning discharges, use a lightning protector. Protect the children from games with the working device, itis dangerous. 5 6 v107_211201 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU Manufacturer and vendor: DS ELECTRONICS, LTD 04136, Ukraine, Kyiv region, Kyiv, 13 Pivnichno-Syretska str. +38 (091) 481-91-81, Service Center: +38 (091) 481-91-81 7 support@dse.com.ua www.ds-electronics.company