EDISIBEINT IMN DBEX INOX Magnetic Level Switch
Product Overview
The EDISIBEINT IMN DBEX INOX is a magnetic level switch designed for reliable level detection in industrial processes. It features a robust stainless steel construction and is suitable for use in hazardous environments when properly integrated with safety barriers.
Key Specifications
- Process connection: Via flange, Stainless Steel AISI316 (see Table 1 for options).
- Body: Stainless Steel AISI316, Ø 12 mm.
- Length: 90 to 3500 mm.
- Float: Type FEI601M13 (FEI-1), Ø 52x52 mm, Stainless Steel AISI316 (Other types optional, see Table 2).
- Max. number of contacts: 1 to 4.
- Contact rating: NO: 80 WVA/250 VAC-2A; NF: 60 WVA/220 VAC-2A; NO/NF: 60 WVA/220 VAC-2A.
- Contact gap: > 40 mm.
- Electrical connection: Via PBT connection box (64 x 95 x 110 mm).
- Separation height (LS): Standard separation height is available; higher separations can be requested.
- Temperature range: -40°C to +125°C.
- Mounting position: Vertical, ±15°.
- Protection class: Standard IP 65 (Other options available, see Table 3).
Diagram Descriptions
Diagram 1 (Product Image): Shows the EDISIBEINT IMN DBEX INOX magnetic level switch, a sensor head mounted on a flange.
Diagram 2 (Device Cross-section): Illustrates the IMN DBEX INOX level switch with a float mechanism. It shows the connection via flange, the sensor body, and the float attached to a rod, indicating dimensions and separation height.
ATEX Compliance and Electrical Equipment
The DBEX IMN stainless steel sensor is classified as simple 'electrical equipment' and does not require ATEX marking or certification itself. It is suitable for use in intrinsically safe classified zones when connected to appropriate related equipment, such as a Zener barrier or galvanic isolator. The applicable ATEX category and zone depend on the connected safety device.
Applicable Zones: Zone 0, 1, 2, 20, 21, and 22, as defined by standard UNE-EN60079-25 and directive 2014/34/UE.
ATEX Certified Components:
- Box: FM08ATEX0010U - EX II 2 G Ex d IIC Gb / II 2 D Ex tb IIIC Db
- Terminals: TÜV18ATEX8221U - Ex II 2 GD Ex eb IIC Gb
- Cable gland: LCIE 07 ATEX 6082X - XII 2 G/D Ex e II Ex tD A21 IP68
Technical Tables
Table 1: Process Connection (Flange)
| Flange Type | DN25 | DN32 | DN40 | DN50 | DN100 |
|---|---|---|---|---|---|
| Øt (mm) | 4x14 | 8x18 | |||
| d (mm) | 85 | 100 | 110 | 125 | 180 |
| ØD (mm) | 115 | 140 | 150 | 165 | 220 |
| Thickness (mm) | 18 | 20 |
Table 2: Floats
| Type | Dimension (mm) | Pressure (kg/cm²) | Density (g/cm³) | Figure |
|---|---|---|---|---|
| FCI602M13 | Ø 44x63 | 15 | e > 0.75 | 15.8 / 47.2 |
| FEI601M13 | Ø 52x52 | 30 | e > 0.76 | 12.5 / 39.5 |
| FEI602M13 | Ø 95x95 | 30 | e > 0.36 | 60.8 / 34.2 |
Ordering Code
The ordering code is composed by selecting options for each parameter. If the standard separation height (LS) is used, it does not need to be specified in the code.
Structure: IMN DBEX INOX - V P S C N
- Float: FEI601M13 (14), FEI602M13 (25), FCI602M13 (29)
- Process Connection: DN25 (34), DN32 (35), DN40 (36), DN50 (37), DN100 (39)
- Version: V3
- Encapsulated: C2
- Number of contacts: 1-3
- Number of floats: 1-3
- Separation (LS) (mm): Specify if non-standard.
- Total Length (LT) (mm): Specify length.
Example: IMN DBEX INOX V3 P34 F14 L500 C2 N1
Application Examples and Safety
Application Example 1: Classified Zone Sensor
Diagram Description: Shows a setup with a classified zone and a safe zone, featuring the sensor, electrical isolation, and solenoid start-stop operation.
Intrinsic Safety ('ia') Setup
Diagram Description: Illustrates an intrinsic safety setup connecting a magnetic switch to a safe zone via a safety barrier (AG-5202-B), which acts as a galvanic isolator.
Safety Instructions
- Equipment must be powered by a safety barrier with at least Ex ia IIC characteristics.
- The safety barrier must be mounted in a safe zone, following manufacturer instructions, to prevent circuit contamination.
- Users must perform intrinsic safety loop calculations and include them in the System Description Document (DDS).
Complementary Information: AG-5202-B Galvanic Isolator
The AG-5202-B is a galvanic isolator for contacts, ATEX classified. It is designed for safe integration in hazardous environments.
- Mounting dimensions: 109 x 23.5 x 130 mm (DIN rail).
- Ex/ I.S. Approval: Ex II (1) G D [EEx ia] IIC. Applicable Zones: 0, 1, 2, 20, 21, or 22.
- Input: 2 Contacts.
- Output AG-5202-B2: 1 SPDT, 2A/250VAC.
- Output AG-5202-B4: 2 SPST NO, 2A/250VAC.
- Power Supply: 24..230 VAC ± 10% 50/60 Hz or 24..250 VDC ± 20%.
- Safety zone limit parameters: Uo = 10.6 Vdc, Io = 13.8 mAdc, Po = 38 mW, Lo = 160 mH, Co = 1.9 μF.
- Required values for safe assembly: Maximum energy at Reed contact: P ≈ 0.029 mW. Required conductor inductance with 3m of 0.5mm² cable: L ≈ 5.17 μH. Capacitance of two parallel 3m cables (0.5 mm²): P ≈ 33 pF.
- Thermal resistance: Rth = 1.14 k/W.