Black Box CL050A-R3 User Manual

Black Box RS-232 to Current-Loop Interface Bidirectional Converter - Transceiver - RS-232 - serial - up to 3 km

Black Box CL050A-E User Manual

Black Box - Transceiver - RS-232 - serial - up to 3 km

RS-232 Current Loop Interface Converter (232/CL-E)

CUSTOMER SUPPORT INFORMATION SEPTEMBER 1998 CL050A CL050A-R2 CL050C CL050AE RM005 RS-232 ↔ Current Loop Interface Converter (232/CL-E) 232/CL-E RX TX Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA ...


File Info : application/pdf, 23 Pages, 196.29KB

PDF preview unavailable. Download the PDF instead.

CL050A 27799
SEPTEMBER 1998 CL050A
CL050A-R2 CL050C
CL050AE RM005
RS-232  Current Loop Interface Converter (232/CL-E)

232/CL-E

RX

TX

CUSTOMER SUPPORT
INFORMATION

Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com · E-mail: info@blackbox.com

FCC STATEMENT
FEDERAL COMMUNICATIONS COMMISSION AND
CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
3

INSTRUCCIONES DE SEGURIDAD
NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato eléctrico no deberá ser usado cerca del agua--por ejemplo, cerca
de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que
sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea
recomendado por el fabricante. 8. Servicio--El usuario no debe intentar dar servicio al equipo eléctrico más allá
a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación. 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
4

INSTRUCCIONES DE SEGURIDAD
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o E: El aparato ha sido tirado o su cubierta ha sido dañada.
5

RS-232  CURRENT LOOP INTERFACE CONVERTER
TRADEMARKS All applied-for and registered trademarks are the property of their respective owners.
6

RS-232  CURRENT LOOP INTERFACE CONVERTER
CONTENTS 1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 4. The Current-Loop Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
4.1 Testing for Other Active Devices on the Current Loop . . . . . . .11 4.1.1 LED Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 4.1.2 Voltmeter Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4.2 Connecting the Current Loop Wires to the CL050A . . . . . . . . .12 4.2.1 4-Wire Current Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 4.2.2 2-Wire Current Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.3 Switch SWA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 4.4 Switch SWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 5. The RS-232C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 5.1 The RS-232C Interface Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . .18 5.2 Switch SWC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
5.2.1 DCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 5.2.2 DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 6. Operations and Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 6.1 Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 6.2 Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 7. Current Loop Rack and Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 7.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 7.2 Specifications for RM005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
7

RS-232  CURRENT LOOP INTERFACE CONVERTER
1. Specifications

Connectors -- RS-232/CCITT V.24: DB25 (female) Current Loop: 4 screw terminals

Indicators --

(2) LEDs indicating RS-232 port activity: RX for Receive Data from an RS-232 external device TX for Transmit Data to an RS-232 external device

Switches --

10-position DIP switch for current-loop transmission mode 10-position DIP switch for RS-232 DTE or DCE configuration 4-position DIP switch for electrical current in the current loop

Maximum Transmission

Distance --

(based on using 24-AWG solid copper wire):

at 9600 bps: 300 to 400 meters

(984 to 1,312 feet)

at 300 bps: 1000 to 3000 meters (3,281 to 9,843 feet)

Power --

Input -- 115/220 VAC, 50 to 60 Hz, 12W Output -- 18 VAC, center tapped, 8VA

Size --

1.75"H x 5.5"W x 8.5"D (4.4 x 14 x 21.6 cm)

Weight --

1.5 lb. (0.7 kg)

CAUTION
Make sure you have the right power supply for your local power. If not, call Technical Support to get a replacement power supply.

8

RS-232  CURRENT LOOP INTERFACE CONVERTER

2. Introduction

The RS-232  Current Loop Interface Converter (CL050) is a bidirectional self-contained unit that enables the interconnection of a digital 20/30/60mA unipolar current-loop interface with an RS-232 interface. The CL050 cannot be used with an analog current loop (4 to 20 mA) or bipolar current loop.
Current loop was designed to transfer data in a noisy environ-ment with as much integrity as possible. The maximum distance that the CL050 can be placed from other devices on the current loop (see Chapter 1) is based on using 24 AWG under ideal conditions, with the CL050 designated as the active device in a point-to-point configuration.
The CL050 can act as either an active or passive device on the current loop. As an active device, the CL050 supplies 20, 30, or 60 ma loop current at 18 VDC for operation. As a passive device,

the CL050 will not supply loop current, but it will operate with 20, 30, or 60 ma unipolar current at up to 30 VDC.
WARNING!
Only one device on the current loop may be active. If more than one device is active, each of the devices will be permanently damaged. Refer to Sections 4.1 and 4.2 for instructions on testing the current loop and connecting it to the CL050.
Switch selections allow for half-duplex or full-duplex operation; 20, 30, or 60 mA loop current; and configuring the CL050 as either DTE or DCE.
Two LEDs monitor data flow.
If you ordered the CL050A-R2, you should have received cables with it.
A 220-volt power supply (CL050E) is also available.

Current Loop Device

CL050
Device using RS-232 Interface
Figure 2-1. With the CL050, you can interconnect a current loop interface and an RS-232 interface.

9

RS-232  CURRENT LOOP INTERFACE CONVERTER

3. Installation

1. Remove the screw located at the center of the bottom cover.
2. Remove the top cover.
3. Lift the back panel from its guide.
4. Insert the power supply receptacle into the 4-prong plug (See Figure 7-1 on page 16. The 4-prong plug is near W1). The receptacle should be aligned so that the lip is on the upward side. DO NOT PLUG THE POWER SUPPLY
INTO AN AC OUTLET!
5. Test your current loop for active devices. See Section 4.1 on page 11.
6. Connect your current loop to the CL050. See Section 4.2 on page 12.

7. Insert the back panel into its guide, making sure the powersupply cable and current-loop cable exit through the holes provided for them.
8. Set switches SWA, SWB and SWC to the desired positions. The CL050 is shipped with SWA set to Full-Duplex, Passive; SWB set to 20mA receive; 20mA transmit; and SWC set to DTE. See Sections 4.3, 4.4, and 5.2, respectively, on pages 11 and 13 for more information on these switches.
9. Replace the top cover.
10. Replace the screw.
11. Attach your RS-232C cable.
12. Plug the power supply into an AC outlet. The CL050 is now ready for operation.

10

RS-232  CURRENT LOOP INTERFACE CONVERTER

4. The Current-Loop Interface

4.1 Testing for Other Active Devices on the Current Loop
You must test for an active device on the current loop if you plan to have the CL050 supply loop current.
WARNING!
Only one device on the current loop may be active. If more than one device is active at the same time, each device will be permanently damaged.
There are two tests that you can run. Either is sufficient.

4.1.1 LED TEST (1) Unplug the CL050 from the AC outlet.
(2) Set the SWA switch to full duplex, passive.
(3) Attach the T- of the 4-wire current loop device (or "-" in a 2-wire current loop) to R- of the CL050A.
(4) Attach the T+ of the 4-wire current loop device (or "+" in a 2-wire current loop) to R+ of the CL050A. See Figure 4-1 (4-wire current loop) or Figure 4-2 (2-wire current loop).
(5) Plug the CL050 into the AC outlet.

RT++
RT-T+R+ T-R-

T+

T-

CL050A

R+

R-

Figure 4-1. Wiring configuration for a 4-wire current loop LED test.

T+

T+

+

T-

CL050A

-

R+

R-

R-

Figure 4-2. Wiring configuration for a 2-wire current loop LED test.

11

RS-232  CURRENT LOOP INTERFACE CONVERTER

4-Wire Full-Duplex
2-Wire Half-Duplex Passive
2-Wire Half-Duplex Active

1 (T+) + Receive
+ Loop
No Connection

Terminals

2 (T-)

3 (R+)

- Receive

+ Transmit

Jumper to 3 (R+)

Jumper to 2 (T-)

+ Loop

- Loop

4 (R-) - Transmit
- Loop
No Connection

Table 1. Current Loop Cable Connections.

(6) Test results:
(a) If the TX LED on the CL050 is off, the other device is active.
(b) If the TX LED on the CL050 lights continuously, there is no current in the loop. Therefore, the other current-loop device is passive.
(c) If the TX LED flashes, the current loop is sending data. This indicates that the other device is active.
(7) Unplug the CL050 from the AC outlet and remove the R- to R- and R+ to R+ wires.
4.1.2 VOLTMETER TEST Attach the voltmeter to the two Transmit lines (T+ and T-) of a current loop device (not the CL050). If the voltmeter reads voltage, the device is active. If no voltage registers, the device is passive.

4.2 Connecting the Current Loop Wires to the CL050A
When you attach current loop wires to the CL050, the unit should not be connected to an AC outlet. Unless very fine stranded-wire cable is used, wire tinning is not required. Just insert the wire into the receptacle and tighten the screw. The wire will be firmly gripped by the terminal. Table 1 details how the current loop should be connected to the CL050. Refer also to Figures 4-3 through 4-7 on pages 8, 9, and 10.
4.2.1 4-WIRE CURRENT LOOP
Regardless of whether the CL050 is active or passive, attach the current loop wires as indicated in Table 1 and as shown in Figures 4-3 or 4-4.

12

RS-232  CURRENT LOOP INTERFACE CONVERTER
4.2.2 2-WIRE CURRENT LOOP Connections to a 2-wire half-duplex multipoint current loop depend on whether the CL050 is used as an active or passive unit. Note the connections in Table 1. The connections are also shown in Figures 4-5, 4-6, and 4-7. Note: Not all 2-wire current loops are bidirectional half-duplex. Some current loops are simplex.
13

RS-232  CURRENT LOOP INTERFACE CONVERTER

T+

R+

T-

R-

R+

T+

R-

T-

Figure 4-3. 4-Wire Point-to-Point.

T+

T-

T+

R+

T-

R-

R+

R-

Active

T+

T-

R+

R-

Passive Passive

T+ TR+ R-
Figure 4-4. 4-Wire Multipoint.

Passive

14

RS-232  CURRENT LOOP INTERFACE CONVERTER

Passive
+ -

T+ TR+ R-

CL050 (set to half-duplex active)

Figure 4-5. 2-Wire Point-to-Point (half-duplex).

T+ TR+ R-
CL050 (Passive)

Jumper

+ Passive
-

+

Active

-

+ Passive
-

Figure 4-6. 2-Wire Half-Duplex Multipoint (CL050 passive).

15

RS-232  CURRENT LOOP INTERFACE CONVERTER

T+ TR+ R-
CL050 (active)

+ Passive
-

+ Passive
-

+

Passive

-

Figure 4-7. 2-Wire Half-Duplex Multipoint (CL050 active).

16

RS-232  CURRENT LOOP INTERFACE CONVERTER

4.3 Switch SWA
Switch SWA controls the Current Loop Configuration. The CL050 is shipped with the SWA in a "Full-Duplex, Passive" configuration.

Note: 0 indicates "OPEN" and 1 indicates "CLOSED."

SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW9 SW10 0101001 01 0 1010110 10 1 0101010 10 1
1010101 01 0
0101001 01 0
0100111 01 0

Loop Configuration
Full-Duplex, Passive
Full-Duplex, Active
Full-Duplex, Passive Receive/Active Transmit
Full-Duplex, Active Receive/Passive Transmit
Half-Duplex, Passive (2-wire operation)
Half-Duplex, Active (2-wire operation)

4.4 Switch SWB
Switch SWB controls loop current (20/30/60 mA). The CL050 is shipped with the SWB in a "20mA receive; 20mA transmit" configuration.

Note: 0 indicates "OPEN" and 1 indicates "CLOSED."

SW1 SW2 SW3 SW4

0

0

0

0

1

1

1

1

1

1

0

0

0

0

1

1

1

0

1

0

Loop Current 20mA receive; 20mA transmit loops 60mA receive; 60mA transmit loops 60mA receive; 20mA transmit loops 20mA receive; 60mA transmit loops 30mA receive; 30mA transmit loops

17

RS-232  CURRENT LOOP INTERFACE CONVERTER

5. The RS-232C Interface

5.1 The RS-232C Interface Pinout

Pin

Circuit

Description

Direction

1

AA

Protective Ground

---

2

BA

Transmit Data

To DCE

3

BB

Receive Data

From DCE

4

CA

Request to Send

To DCE

5

CB

Clear to Send

From DCE

6

CC

Data Set Ready

From DCE

7

AB

Signal Ground

---

20

CD

Data Terminal Ready

To DCE

SIGNAL DESTINATION

RS-232 Interface (Female)

PIN NUMBER

PIN NUMBER

SIGNAL DESTINATION

PROTECTIVE GROUND 1 TRANSMITTED DATA 2 RECEIVED DATA 3 REQUEST TO SEND 4 CLEAR TO SEND 5 DATA SET READY 6
SIGNAL GROUND / COMMON RETURN 7 RECEIVED LINE SIGNAL DETECTOR 8 + VOLTAGE 9 - VOLTAGE 10 11
SECONDARY RECEIVED LINE SIGNAL INDICATOR 12 SECONDARY CLEAR TO SEND 13

14 SECONDARY TRANSMITTED DATA 15 DCE TRANSMITTER SIGNAL ELEMENT TIMING 16 SECONDARY RECEIVED DATA 17 RECEIVER SIGNAL ELEMENT TIMING 18 19 SECONDARY REQUEST TO SEND 20 DATA TERMINAL READY 21 SIGNAL QUALITY DETECTOR 22 RING INDICATOR 23 DATA SIGNAL RATE SELECTOR 24 DTE TRANSMITTER SIGNAL ELEMENT TIMING 25

Figure 5-1. The RS-232C Interface.

18

RS-232  CURRENT LOOP INTERFACE CONVERTER

5.2 Switch SWC
Switch SWC controls the RS-232 Connector Configuration (DCE/DTE).

Note: "OPEN" indicates Off and "CLOSED" indicates On.

5.2.1 DCE The CL050 default configuration is DCE. The 10-position DIP switch is set as follows:

SW1 SW2
SW3 SW4
SW5 SW6 SW7 SW8
SW9 SW10

Not Used OPEN
CLOSED OPEN
CLOSED OPEN CLOSED OPEN
CLOSED Not Used

= SW2 and SW3 are ALWAYS in opposite positions
= With SW2 OPEN, Data Out is on Pin 3 = SW4 and SW5 are ALWAYS in opposite
positions = With SW4 OPEN, Data In is on Pin 2 = Pin 4 (RTS) not connected = Ties Pin 5 (CTS) to Pin 20 (DTR) = Removes High on Pin 20 (DTR). If
system does not use DTR, raise CTS by CLOSING both SW7 and SW8 = Place High on Pin 6 (DSR)

5.2.2 DTE When configuring the CL050 as a DTE, the 10-position DIP switch is set as follows:

SW1 SW2 SW3
SW4 SW5
SW6 SW7 SW8 SW9 SW10

Not Used CLOSED OPEN
CLOSED OPEN
CLOSED OPEN CLOSED OPEN Not Used

= With SW3 OPEN, Data Out is on Pin 2 = SW2 and SW3 are ALWAYS in opposite
positions = With SW5 OPEN, Data In is on Pin 3 = SW4 and SW5 are ALWAYS in opposite
positions = Place High on Pin 4 (RTS) = Pin 5 (CTS) not connected = Place High on Pin 20 (DTR) = Pin 6 (DSR) not connected

19

RS-232  CURRENT LOOP INTERFACE CONVERTER
6. Operations and Troubleshooting

6.1 Indicators
TX LED
On Continuously: Indicates (1) receive current loop not attached; (2) no current flowing; or (3) you have an open loop. Check the polarity of the receive loop and/or the active/passive options.
Off: The CL050 is not connected to an AC outlet or loop current is flowing continuously (which is normal in an idle state).
Flashing: Data is being transmitted from the RS-232 port to the RS232C interface.

RX LED On Continuously: Error. Call
Technical Support.
Off: No data being received by the RS232 port.
Flashing: Data is being received by the RS-232 port from the RS-232C interface.

20

RS-232  CURRENT LOOP INTERFACE CONVERTER

6.2 Self Test
Follow these instructions to test the internal circuitry of the CL050:
(1) Unplug the CL050 from AC outlet.
(2) Set switch SWA to full-duplex, transmit active, receive passive.
(3) Set switch SWC to DCE configuration.
(4) Attach a DTE device using a straight-pinned cable from the DTE to the CL050.
(5) On the CL050, connect a wire from T- to R-.

(6) On the CL050, connect a wire from T+ to R+.
(7) Plug the CL050 into an AC outlet.
(8) Set the DTE device to full-duplex.
(9) Enter data.
(10) The TX and RX LEDs should flash and the data should display on the DTE's monitor. If this occurs, all internal circuitry is operational.

RS-232C Cable DTE

CL050
DCE Configuration

T+
-
R+
-

Figure 6-1. Wiring for the Internal Circuitry Test.

21

RS-232  CURRENT LOOP INTERFACE CONVERTER

7. Current Loop Rack and Cards

7.1 Description
The RM005 Rack can hold up to 16 CL050C printed circuit cards and fits in a standard 19-inch equipment rack. The RM005 comes complete with its own built-in AC power supply. The operation of the CL050C is the same as the CL050.
WARNING!
Do not apply primary power until after you have properly configured the RM005 power supply.
· For 115 VAC ±15% primary power: Set 115/230

voltage selector switch to 115 and make sure the input fuse is rated at 1 A.
· For 230 VAC ±15% primary power: The voltage selector switch must be set to 230 and the fuse must be rated 0.5 A.
Inside the fuseholder are two fuses. Open the fuseholder by pressing down on the cover, then release. The fuse closest to the cover is a spare. Select the correct fuses and place them in the Fuse Retaining Cover. Discard the incorrect fuses.

CURRENT LOOP INTERFACE CONNECTOR

POWER CONNECTOR
RS-232 INTERFACE CONNECTOR

T+ TR+ RWI
DTE/DCE U1 U2
SW C

U6

U5

C5 C4

C6

C7

Q2 Q3 U3
SW B

Q1 U4

SWITCH C (DTE/DCE)

SWITCH B (20/30/60 mA)

TD
LEDs RD

SW A

SWITCH A (Current Loop Configuration)

Figure 7-1. Component Layout.

22

RS-232  CURRENT LOOP INTERFACE CONVERTER

7.2 Specifications for RM005
Power--115/230 VAC, 60/50 Hz, switch-selectable

Rack Size --

Overall Width: 19" (48.3 cm)

Inside Width: 17" (43.2 cm)

Depth:

10.5" (26.7 cm)

Height:

5.25" (13.3 cm)

PC Card Size --

Length:

7.5" (19.1 cm)

Width:

3.6" (9.1 cm)

Rack Weight --

19.6 lb. (8.9 kg) (without cards installed)

PC Card Weight -- 4.5 ounces (128 g)

Rack Switches --

On/Off Power Switch

115/230 VAC Selector Switch

Rack Indicators -- None

Figure 7-2. RM005 with CL050C. 23

© Copyright 1998. Black Box Corporation. All rights reserved. 1000 Park Drive · Lawrence, PA 15055-1018 · 724-746-5500 · Fax 724-746-0746

