Owner's Manual for Soler Palau models including: MBE-100-04B-R, MBE-100-08B-R, MBE-125-04B-R, MBE-125-08B-R, MBE-125-12B-R, MBE-160-07B-R, MBE-160-14B-R, MBE-160-21B-R, MBE-200-20T-R, MBE-200-30T-R, MBE-200-40T-R, MBE-200-50T-R, MBE-200-60T-R, MBE-250-20T-R, MBE-250-30T-R, MBE-250-40T-R, MBE-250-50T-R, MBE-250-60T-R, MBE-250-90T-R, MBE-315-, MBE-100-04B-R Electric Heaters with Regulation Incorporated, MBE-100-04B-R, Electric Heaters with Regulation Incorporated, Heaters with Regulation Incorporated, Regulation Incorporated, Incorporated
File Info : application/pdf, 3 Pages, 1.33MB
DocumentDocumentELECTRIC HEATERS WITH REGULATION INCORPORATED MBE-R Series Designed to be installed on the fans discharge side.The minimum air speed through the heater must be 1,5 m/s. Maximum air temperature through the heater: 40ºC. The heaters are fitted with: - Tubular structure made of galvanized steel with watertight joints at the entrance and outlet. - Electrical heater regulation, incorporated. - Stainless steel AISI-304 / AISI-321 armoured heating element. - Double protection circuit to connect to the heater control circuit by means of a safety overheat automatic thermostat connected in series with another safety overheat manual reset thermostat (RESET). - Wiring box IP43. For the correct operation of the electric coils it is necessary to use different accessories and installation elements (temperature probe, protection pressure switch, contactors, etc.) which are specified in the corresponding instructions, depending on the installation to be carried out. TECHNICAL CHARACTERISTICS Modelo MBE-100/04B-R MBE-100/08B-R MBE-125/04B-R MBE-125/08B-R MBE-125/12B-R MBE-160/07B-R MBE-160/14B-R MBE-160/21B-R MBE-200/20T-R MBE-200/30T-R MBE-200/40T-R MBE-200/50T-R MBE-200/60T-R MBE-250/20T-R MBE-250/30T-R MBE-250/40T-R MBE-250/50T-R MBE-250/60T-R MBE-250/90T-R MBE-315/30T-R MBE-315/60T-R MBE-315/90T-R MBE-315/120T-R MBE-355/60T-R MBE-355/90T-R MBE-355/120T-R MBE-400/60T-R MBE-400/90T-R MBE-400/120T-R MBE-400/150T-R MBE-450/90T-R MBE-450/150T-R MBE-500/60T-R MBE-500/90T-R MBE-500/120T-R Voltage (V) 1/230 1/230 1/230 1/230 1/230 1/230 1/230 1/230 2/400 2/400 2/400 2/400 2/400 2/400 2/400 2/400 2/400 2/400 3/400 2/400 2/400 3/400 3/400 2/400 3/400 3/400 2/400 3/400 3/400 3/400 3/400 3/400 2/400 3/400 3/400 www.solerpalau.com Power (W) 400 800 400 800 1200 700 1400 2100 2000 3000 4000 5000 6000 2000 3000 4000 5000 6000 9000 3000 6000 9000 12000 6000 9000 12000 6000 9000 12000 15000 9000 15000 6000 9000 12000 Minimum airflow (m3/h) 50 50 70 70 70 110 110 110 170 170 170 170 170 270 270 270 270 270 270 430 430 430 430 540 540 540 680 680 680 680 860 860 1.070 1.070 1.070 Ø (mm) 100 100 125 125 125 160 160 160 200 200 200 200 200 250 250 250 250 250 250 315 315 315 315 355 355 355 400 400 400 400 450 450 500 500 500 Heating range MBE-R 843 ELECTRIC HEATERS WITH REGULATION INCORPORATED MBE-R Series DIMENSIONS (mm) Model D 290 A MBE-100 100 MBE-125 125 MBE-160 160 MBE-200 200 MBE-250 250 MBE-315 315 B MBE-355 355 MBE-400 400 MBE-450 450 MBE-500 500 50 400 PERFORMANCE CURVES MBE - Pressure drop p (Pa) [Pa] 120 80 40 0 1 2 3 4 5 Model 100/04B 100/08B 125/04B 125/08B 125/12B 160/07B 160/14B 160/21B 200/21B 200/20T 200/30T 200/40T 200/50T 200/60T 200/90T Curve 1 7 1 5 6 1 4 5 2 2 4 5 6 7 10 Model 250/20T 250/30T 250/40T 250/50T 250/60T 250/90T 315/30T 315/60T 315/90T 315/120T 315/150T 355/60T 355/90T 355/120T 355/150T 6 7 Curve 1 2 2 4 5 7 1 2 4 5 8 2 3 4 7 10 9 8 7 6 5 4 3 2 1 8 9 [m/s] Model 355/180T 400/60T 400/90T 400/120T 400/150T 400/180T 450/90T 450/150T 500/60T 500/90T 500/120T 500/150T 500/180T Curve 9 1 2 3 8 10 2 7 1 1 2 4 7 SELECTION EXAMPLE DATA: - Airflow: 700 m3/h (Q) - Temp. of supplied air: 5ºC - Temp. of exhausted air: 27ºC ELECTRIC HEATER POWER REQUIRED: P = Qx0,36xT = 700x0,36x22 = 5544 W HEATER SELECTION MBE-200/50T-R or MBE-250/60T-R (Diagram 2) The final selection depends on: - Total system pressure drop - Desired sound level - Available space 844 Heating range MBE-R www.solerpalau.com ELECTRIC HEATERS ACCESSORIES ELECTRIC HEATER ACCESSORIES For more information see electrical accessories. PULSER Single phase electric heater controller. TTC-2000 Three phase electric heater controller. TG-R Room temperature sensor. TG-R430: Adjustable TG-R530: Not adjustable PRESOSTATO DPS Differential pressure switch. TT-S4/D Module to increase the controller power TTC-40F, up to 66kW. TTC-25 and TTC-40F Three phase electric heater controller. TT-S1 Additional PCB to increase the output power controlled. TG-K Duct temperature sensor. TBI-10 / TBI-30 External potentiometer. TRAFO-15D Transformer to power the TT-S4/D to 24V. www.solerpalau.com Heating range ACCESSORIES 845