User Manual for MEAN WELL models including: LSP-160 Series, 160W Slim Type with PFC Switching Power Supply, LSP-160 Series 160W Slim Type with PFC Switching Power Supply, Slim Type with PFC Switching Power Supply, Slim Type
LSP-160-3.3T MEAN WELL | Jameco Electronics
File Info : application/pdf, 7 Pages, 659.98KB
DocumentDocument160W Slim Type with PFC Switching Power Supply LSP-160 series User's Manual Video GB4943 UL62368 Bauar t gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368 IEC62368 Industrial automation machinery Industrial control system Mechanical and electrical equipment Electronic instruments, equipments or apparatus Household appliances LED display application LSP-160 series is a 160W single-output slim type power supply with 20mm of low profile design. Adopting the full range 100~264VAC input, the entire series provides an output voltage line of 3.3V,4.2V,5V, 12V, 24V, 36V and 48V. In addition to the high efficiency up to 93.5%, that the whole series operates from -30 ~ 70 under air convection without fan. LSP-160 has the complete protection functions and 5G anti-vibration capability; It is complied with the international safety regulations such as TUV BS EN/EN62368, UL62368 and GB4943. LSP-160 series serves as a high performance power supply solution for various industrial applications. : R File Name:LSP-160-SPEC 2021-09-24 160W Slim Type with PFC Switching Power Supply LSP-160 series SPECIFICATION MODEL LSP-160 -3.3 LSP-160 -4.2 LSP-160 -5 LSP-160-12 LSP-160-24 LSP-160-36 LSP-160-48 DC VOLTAGE 3.3V 4.2V 5V 12V 24V 36V 48V OUTPUT RATED CURRENT 32A 32A 32A 13.5A RATED POWER(convection) 105.6W 134.4W 160W 162W RIPPLE & NOISE (max.) Note.2 200mVp-p 200mVp-p 200mVp-p 240mVp-p VOLTAGE ADJ. RANGE 3.2~3.5V 4~4.5V 4.7~5.3V 11.4~12.6V VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.3% LOAD REGULATION ±1.0% ±1.0% ±1.0% ±0.5% SETUP, RISE TIME 2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load 6.75A 162W 240mVp-p 22.8~25.2V ±1.0% ±0.3% ±0.5% 4.5A 162W 240mVp-p 34.2~37.8V ±1.0% ±0.3% ±0.5% 3.4A 163.2W 300mVp-p 45.6~50.4V ±1.0% ±0.3% ±0.5% HOLD UP TIME (Typ.) 10ms/230VAC VOLTAGE RANGE Note.4 100 ~ 264VAC 10ms/115VAC 141 ~ 370VDC FREQUENCY RANGE POWER FACTOR (Typ.) 47 ~ 63Hz PF0.94/230VAC PF0.98/115VAC at full load INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 87.5% 88.5% 89.5% 2.2A/115VAC 1.1A/230VAC Cold start 45A/115VAC 85A/230VAC 92.5% 93.5% 93.5% 93.5% LEAKAGE CURRENT SHORT CIRCUIT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE <0.75mA / 240VAC Hiccup protection,recovers automatically after fault condition is removed 110~140% rated output power Protection type : Constant current limiting,continous increase of load will be hiccup protection, recovers automatically after fault condition is removed 3.8~ 4.6V 4.62 ~ 5.46V 5.75 ~ 6.75V 13.2 ~ 15.6V 26.4 ~ 31.2V 39.6 ~46.8V 52.8 ~ 62.4V Protection type :Shut down O/P voltage,re-power on to recover Shut down O/P voltage, re-power on to recover after temperature goes down FUNCTION CURRENT SHARING DC OK SIGNAL Please refer to the Function Manual Contact rating(max.):15Vdc/10mA resistive load WORKING TEMP. -30 ~ +70(Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368,TUV BS EN/EN62368, CCC GB4943, EAC TP TC 004, BSMI CNS14336-1 approved, Design refer to BS EN/EN60335-1 SAFETY & EMC (Note.6) WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25/ 70%RH Compliance to BS EN/EN55032,GB9254,Class B, BS EN/EN55014,BS EN/EN61000-3-2,-3,EAC TP TC 020,BSMI CNS13438 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level ,criterial A,EAC TP TC 020 OTHERS MTBF DIMENSION 699.54K hrs min. Telcordia TR/SR-332(Bellcore) ;282.71K hrs min. MIL-HDBK-217F (25) 194*55*20mm (L*W*H) NOTE PACKING 0.356kg;30pcs/11.68kg/0.6CUFT http://www.meanwell.com , https://www.meanwell.com/serviceDisclaimer.aspx File Name:LSP-160-SPEC 2021-09-24 160W Slim Type with PFC Switching Power Supply LSP-160 series Block Diagram EMI FILTER I/P & RECTIFIER PFC CIRCUIT POWER SWITCH- ING RECTIFIERS & FILTER PFC fosc:133KHz PWM fosc:70KHz~110KHz +V -V FG DETECTION O.T.P. O.L.P. CONTROL CIRCUIT LOAD SHARING CS O.V.P. RATED CURRENT (%) DC OK Function Derating Curve 100 80 60 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () RATED CURRENT (%) 230Vac for 3.3V,4.2V,5V 75 65 100Vac for 12V,24V,36V,48V 50 45 100Vac for 3.3V, 4.2V, 5V 30 230Vac for 12V,24V,36V,48V -20 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE() STATIC CHARACTERISTIC RATED CURRENT (%) 100 80 60 40 20 -30 0 20 30 40 60 70 80 90 (HORIZONTAL) Tcase () NOTE: Tc measurement point ,please refer page 5 mechanical specification. LOAD (%) 100 90 80 70 60 50 40 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (V) 60Hz File Name:LSP-160-SPEC 2021-09-24 160W Slim Type with PFC Switching Power Supply LSP-160 series Function Manual 1.DC_OK Signal DC_OK is a collector shorted signal. It is used by an optocoupler in the power supply which indicates the output status of the power supply as exhibited below. +V DC OK +V 1 K Optocoupler C-E Pin Conduction PSU turns on DC ok Optocoupler C-E Pin Open Optocoupler Rating(max.) PSU turns off DC fail 15Vdc/10mA resistive load EC GND PSU Power Status DC_OK signal Normal Short circuit/OLP COM OVP/OTP/Breakingdown Low Hiccup High 2.Redundant function (Current sharing): LSP-160 has built-in active current sharing function and can be connected in parallel, up to 2 units, to provide higher output power as exhibited below : The power supplies should be paralleled using short and large diameter wiring then connected to the load. Difference of output voltages among parallel units should be less than 0.2V(Can Fine tune by SVR1). When in parallel operation the maximum load should not be greater than 90% of load from each unit. When out current<( 30% rate current)×(Number of unit),the current shared among units may not be fully balanced. And the LED indicator maybe flash of one of them,but not effacting normal working. PSU PSU +V -V CS+ CS- +V -V CS+ CS- +V -V LOAD CS+/CS- on CN1 are connected mutually in parallel(Note:CS+/CS- do not reverse connection). File Name:LSP-160-SPEC 2021-09-24 160W Slim Type with PFC Switching Power Supply LSP-160 series Mechanical Specification T-type(Terminal block) 4.25 194 130 185.5 CASE NO.:279 Unit:mm 6.5 21 7.62 4*3.3 TB1 tc Vo ADJ. 25 1 TB3 2 3 TB2 4 CS OK DC - - + + 42 55 1 2 CN2 1 2 CN1 21 20 AC Input Connector(TB1) pin NO. Assignment Pin No. Assignment Terminal Max mounting torque 1 AC/L 3 5 AC/N (DEGSON) DG28C-B-03P 5Kgf-cm DC OK Connector(CN2):JST B2B-PH-K-S or equivalent Pin No. Assignment Mating Housing Terminal 1 DC OK +V JSTSPH-002T-P0.5S JSTPHR-2 2 DC COM or equivalent or equivalent CS+/CS- Connector(CN1):JST B2B-PH-K-S or equivalent Pin No. Assignment Mating Housing Terminal 1 CS+ JSTPHR-2 JSTSPH-002T-P0.5S 2 CS- or equivalent or equivalent DC Output Connector(TB2/TB3)pin NO. Assignment Pin No. Assignment Terminal Max mounting torque 1,2 +V (MW) 3,4 -V TB-HTP-200-40A 8Kgf-cm CN mating cable: 1FF5LSP-160-CS(Optional) CN1 and CN2 mating cable by request, please consult MEANWELL for details File Name:LSP-160-SPEC 2021-09-24 160W Slim Type with PFC Switching Power Supply LSP-160 series W-Type(Wafer connector type optional) 194 130 4.25 185.5 4*3.3 TB1 5 3 1 TB1 tc Vo ADJ. 25 CS OK DC - - + + CASE NO.:279 Unit:mm 6.5 21 1 2 1 CN2 2 97 55 42 3 4 1 2 CN1 21 20 AC Input Connector(TB1) pin NO. Assignment Pin No. Assignment Mating housing Terminal 1 AC/L 3 AC/N JS-1391-05 JS-1390-05 and JS-2420-TL 5 DC OK Connector(CN2):JST B2B-PH-K-S or equivalent Pin No. Assignment Mating Housing Terminal 1 DC OK +V JSTSPH-002T-P0.5S JSTPHR-2 2 DC COM or equivalent or equivalent CS+/CS- Connector(CN1):JST B2B-PH-K-S or equivalent Pin No. Assignment Mating Housing Terminal 1 CS+ JSTPHR-2 JSTSPH-002T-P0.5S 2 CS- or equivalent or equivalent DC Output Connector(+V/-V)pin NO. Assignment Pin No. Assignment Mating housing Terminal 1,2 +V 3,4 -V 1EE4LSP-160F 1EE4LSP-160M CN mating cable: 1FF5LSP-160-CS(Optional) CN1 and CN2 mating cable by request, please consult MEANWELL for details File Name:LSP-160-SPEC 2021-09-24 160W Slim Type with PFC Switching Power Supply LSP-160 series Installation 1.Operate with additional aluminum plate In order to meet the"Derating Curve"and the "Static Characteristics" ,LSP-160 series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and LSP-160 series must be firmly mounted at the center of the aluminum plate. unit:mm M3*4 380 3 380 File Name:LSP-160-SPEC 2021-09-24