Braun ThermoScan IRT6520 ThermoScan Infrared Ear Thermometer Instructions

User Manuals Simplified.

Product Overview

The Braun ThermoScan Infrared Ear Thermometer is designed for accurate, safe, and fast temperature measurements in the ear. It is indicated for the intermittent measurement and monitoring of human body temperature by consumers in a home use environment.

[Image: A white Braun ThermoScan infrared ear thermometer with a digital display showing "98.6°F" and an "Exactemp" indicator. It has a blue tip and a power button.]

Certain trademarks are used under license from The Procter & Gamble Company or its affiliates. © 2021 All rights reserved.

Patents: www.kaz.com/patents/braun

P/N: A002208R1 02FEB21

Indications for Use

The Braun ThermoScan Infrared Ear Thermometer is indicated for the intermittent measurement and monitoring of human body temperature by consumers in a home use environment.

Contents

Product Description

Models: IRT6520 / IRT6520B

[Diagram: Illustration of the thermometer with numbered parts.] The thermometer includes:

  1. Lens Filter (Box of 20; Model: LF20)
  2. Probe tip
  3. Probe (Inserted with 1pc of lens filter)
  4. ExacTemp light
  5. Lens filter ejector
  6. Display
  7. Smart and Memory buttons
  8. Power button
  9. Start button
  10. Battery door
  11. Protective case

The Braun ThermoScan Infrared Ear Thermometer is designed for accurate, safe, and fast temperature measurements. Its probe shape prevents deep insertion into the ear canal, protecting the eardrum. Proper technique is crucial for accurate readings. This thermometer is for household use only and is not a substitute for medical consultation.

Warnings and Precautions

Body Temperature

Normal body temperature varies by measurement site, age, and time of day. It is recommended to establish a personal normal temperature range by taking temperatures on yourself and healthy family members.

When consulting a physician, mention that the temperature was measured in the ear and provide the individual's normal ThermoScan temperature range if known.

AgeSmart Color-Coded Display

Clinical research indicates that the definition of fever changes with age. Braun's AgeSmart color-coded display simplifies temperature interpretation for the entire family.

Select the appropriate age setting using the smart button. The display color indicates the temperature:

[Diagram: Illustration showing the AgeSmart display with age groups and corresponding color indicators.] Reference: Herzog L, Phillips S. Addressing Concerns About Fever. Clinical Pediatrics. 2011; 50(#5): 383-390.

How does Braun ThermoScan Infrared Ear Thermometer work?

The thermometer measures infrared heat from the eardrum and surrounding tissues. The probe tip is warmed to body temperature to prevent inaccurate readings. It continuously monitors infrared energy, displaying the result when an accurate measurement is taken.

How to Use Your Braun ThermoScan

  1. Remove the thermometer from its protective case. [Diagram: Thermometer being removed from a blue protective case.]
  2. Press the Power button ?. During an internal self-check, the display shows all segments, then the last temperature taken is displayed for 5 seconds. [Diagram: Thermometer being powered on, showing the power button being pressed. The display shows segments during a self-check, then the last temperature.]
  3. The lens filter indicator will blink ⚠️ when a new filter is needed. Ensure a new, clean lens filter is attached before each measurement for accuracy. Attach by pushing the probe tip straight into the lens filter in the box and pulling it out. Note: The Braun ThermoScan will not work unless a lens filter is attached. [Diagram: Close-up of the probe tip with a blue lens filter attached.]
  4. Select the age with the AgeSmart button ???. Press the button to cycle through age groups: 0-3 Months, 3-36 Months, >36 Months - adult. Note: Age must be selected to take a measurement. The thermometer is ready when the display shows the correct age group and battery status. [Diagram: Illustration showing the AgeSmart button being pressed, cycling through age groups with corresponding icons.]
  5. Fit the probe snugly into the ear canal, then push and release the Start button ▶️. [Diagram: Thermometer probe being inserted into an ear. Arrows indicate gentle insertion.]
  6. The ExacTemp light will pulse while the temperature is in progress. It will remain solid for 3 seconds to indicate a successful reading. A long beep signals a completed measurement if the probe is properly inserted. If the probe position is unstable, short beeps will sound, the ExacTemp light will go out, and a "POS" (position error) message may appear. [Diagram: ExacTemp light pulsing, then solid. Diagram showing a finger pressing the Start button.]
  7. The confirmation beep indicates an accurate measurement. The result is shown on the display. [Diagram: Three examples of the thermometer display showing temperature readings: "37.0°C" (Green, Normal), "37.8°C" (Yellow, Moderate fever), "38.9°C" (Red, High fever), each with age range indicators.] Temperature Ranges:
    Age rangeGreen (Normal temperature)Yellow (Moderate fever)Red (High fever)
    0-3 Months≥35.8 – ≤37.4 °C (≥96.4 – ≤99.4 °F)>37.6–≤38.5 °C (>99.6–≤101.3 °F)>37.4 °C (>99.4 °F)
    >3-36 Months≥35.4–37.6 °C (≥95.7 – ≤99.6 °F)>37.7 – ≤39.4 °C (>99.9 – ≤103.0 °F)>38.5 °C (>101.3 °F)
    >36 Months – adult≥35.4–≤37.7 °C (≥95.7 –≤99.9 °F)>37.7 – ≤39.4 °C (>99.9 – ≤103.0 °F)>39.4 °C (>103.3 °F)
  8. For the next measurement, press the Eject button to remove and discard the used lens filter, and attach a new, clean one. Note: The thermometer defaults to the last age setting used if not changed. The Braun ThermoScan Infrared Ear Thermometer turns off automatically after 60 seconds of inactivity. It can also be turned off by pressing the Power button ?. The display will briefly flash "OFF" and then go blank. [Diagram: Finger pressing the Eject button.]

Temperature Taking Hints

Always replace disposable lens filters for accuracy and hygiene. Measurements may differ between the left and right ear; always use the same ear for consistency. Ensure the ear canal is free from obstructions or excess earwax for accurate readings.

External factors can influence ear temperatures:

FactorYes affects
Poor probe placement✔️
Used lens filter✔️
Dirty lens✔️

Wait 20 minutes before taking a temperature in the following situations:

FactorYes affects
Extreme hot and cold room temperature✔️
Hearing aid use✔️
Lying on pillow✔️

If ear drops or other ear medications have been placed in the ear canal, use the untreated ear.

Memory Mode

This model stores the last 9 temperature measurements. To display stored measurements, the thermometer must be turned on.

  1. Press the Mem button ?. The display shows the temperature. When the Mem button is released, the stored temperature for that memory number is displayed, along with "M". Each press of the Mem button displays the stored reading and an "M" indicator (e.g., M2). Memory mode exits automatically if the memory button is not pressed for 5 seconds. [Diagram: Finger pressing the "Mem" button. Display shows "M 37.6°C".] [Diagram: Examples of memory recall: "M 1 37.6°C", "....", "M 9 37.0°C".]

The last temperature taken is stored in memory and will be automatically displayed for 5 seconds when the thermometer is turned on again. [Diagram: Thermometer turning on, displaying the last temperature taken.]

Night Light Feature

The thermometer includes a night light to illuminate the display in dim environments. The light turns on when any button is pressed and stays on until the thermometer is inactive for up to 10 seconds after a temperature reading.

Changing the Temperature Scale

This thermometer is shipped with the Celsius (°C) scale activated. To switch to Fahrenheit (°F) or back to Celsius:

  1. Ensure the thermometer is turned off.
  2. Press and hold the Power button ? for approximately 3 seconds. The display will show the sequence: °C / SET / °F / SET.
  3. Release the Power button when the desired temperature scale (°C or °F) is shown. A short beep confirms the new setting, and the thermometer turns off automatically.

[Diagram: Illustrations showing the sequence of displays when changing temperature scale: "°C / SET", "°F / SET", "°C", "°F".]

Care and Cleaning

The probe tip is delicate and must be clean and intact for accurate readings.

If the thermometer is accidentally used without a lens filter: Gently wipe the probe tip with a cotton swab or soft cloth moistened with alcohol. After the alcohol has completely dried, attach a new lens filter. If the probe tip is damaged, contact the local service center.

Clean the thermometer display and exterior with a soft, dry cloth. Do not use abrasive cleaners. Never submerge the thermometer in water or any other liquid.

Store the thermometer and lens filters in a dry location, protected from dust, contamination, and direct sunlight.

Replacing the Batteries

The thermometer uses two 1.5 V type AA (LR 06) batteries.

  1. Insert new batteries when the battery symbol ? appears on the display.
  2. Open the battery compartment. Remove old batteries and insert new ones, ensuring correct polarity (+/-).
  3. Snap the battery door back into place.

[Diagram: Diagrams showing how to open the battery compartment and insert batteries.] [Diagram: Batteries with '+' and '-' terminals.]

Dispose of used batteries responsibly at retail stores or designated collection sites according to local regulations.

Calibration

The thermometer is initially calibrated at the time of manufacture. Periodic re-adjustment is not required if used according to instructions.

If you question the accuracy of measurements, contact your authorized service center.

The manufacturing date is indicated by the LOT number in the battery compartment. The first three digits represent the Julian date, and the next two digits represent the last two numbers of the manufacturing year. Example: LOT 11614K means manufactured on the 116th day of 2014.

Errors and Troubleshooting

[Diagram: Icons representing error messages: POS, ERR, HI, LO, System error, Battery low.]

Error MessageSituationSolution
[No lens filter icon]No lens filter is attached.Attach a new, clean lens filter.
POS [POS error icon]The thermometer probe was not positioned securely in the ear. An accurate measurement was not possible. POS = position error.Ensure correct probe positioning and stability. Replace lens filter and reposition. Press the Start button ▶️ to begin a new measurement.
[Ambient temp icon]Ambient temperature is not within the allowed operating range (10 – 40 °C or 50 – 104 °F).Allow the thermometer to remain for 30 minutes in a room where the temperature is between 10 and 40 °C (50 and 104 °F).
HI [HI icon] / LO [LO icon]Temperature taken is not within typical human temperature range (34 – 42.2 °C or 93.2 – 108 °F). HI = too high, LO = too low.Ensure the probe tip and lens are clean, and a new lens filter is attached. Make sure the thermometer is properly inserted. Then, take a new temperature.
[System error icon]System error – self-check display flashes continuously and will not be followed by the ready beep and ready symbol.Wait 1 minute until the thermometer turns off automatically, then turn on again. If the error persists, reset the thermometer by removing and re-inserting the batteries. If the error still persists, please contact the service center.
[Battery low icon 1]The battery is low, but the thermometer will still operate correctly.Insert new batteries.
[Battery low icon 2]The battery is too low to take correct temperature measurement.Insert new batteries.

Model and Product Specifications

ProductThermoScan I RT6520ThermoScan I RT6520B
Temperature measurement within seconds
Temperature range °C34 – 42.234 – 42.2
Temperature range °F93.2 -108.093.2 -108.0
AgeSmart
ExacTemp technology
Feedback system
Ready beep
Small, soft tip
Flexible tip
Memory storage capacity99
Auto-off after60 sec.60 sec.
Easy-to-read LCD display
Lens filter detector
Lens filter ejector
Protective case with lens filter storage
Batteries included
21 lens filter included
ColorBlueBlack
Operating ambient temperature range:10 – 40 °C (50 – 104 °F)
Storage temperature range:-25 – 55 °C (-13 – 131 °F)
Operating and storage relative humidity:10 – 95 %RH (non condensing)
Display resolution:0.1 °C or °F
Accuracy for displayed temperature rangeMaximum Laboratory Error
35 °C – 42 °C (95 °F – 107.6 °F):± 0.2 °C (± 0.4 °F)± 0.2 °C (± 0.4 °F)
outside this range:± 0.3 °C (± 0.5 °F)± 0.3 °C (± 0.5 °F)
Clinical repeatability:± 0.2 °C (± 0.4 °F)± 0.2 °C (± 0.4 °F)
Weight:ThermoScan Infrared Ear Thermometer – 66.9g
Protective case – 43.7g
Battery – 46.4g
Battery life:2 years / 350 measurements
Service life:5 years

Manufactured by KeyTronic Corporation (Address: Tomas Becket #2220 Parque Ind. Gema, Plant 3 Juarez, Chihuahua C.P. 32380 México) for Kaz Europe Sàrl (Address: Place Chauderon 18, CH-1003 Lausanne, Switzerland)

File Downloads

[Image: Cover of Braun Instructions manual.] BRAUN Instructions IRT6520, IRT6520B, ThermoScan, Infrared Ear Thermometer Download [optimized] Download

References

Related Manuals

PDF preview unavailable. Download the PDF instead.

917BjJDnkbL wkhtmltopdf 0.12.6 Qt 4.8.7

Related Documents

Preview Braun ThermoScan IRT6520/IRT6520B Infrared Ear Thermometer User Manual
Comprehensive guide to the Braun ThermoScan IRT6520 and IRT6520B infrared ear thermometers, covering features, usage, troubleshooting, and specifications for accurate temperature measurement.
Preview Braun ThermoScan 7 IRT6520: AgeSmart Infrared Ear Thermometer
An overview of the Braun ThermoScan 7 IRT6520 infrared ear thermometer, detailing its AgeSmart technology for age-adjustable fever guidance, ExacTemp positioning system, pre-warmed tip for accuracy, and hygienic disposable filters. Learn how to use the thermometer and understand fever.
Preview Braun ThermoScan Infrared Ear Thermometer IRT 6030 User Manual
Comprehensive user manual for the Braun ThermoScan Infrared Ear Thermometer, model IRT 6030. Provides instructions for use, product description, safety precautions, troubleshooting, and specifications for accurate home temperature measurement.
Preview Braun ThermoScan 3 Infrared Ear Thermometer User Guide (IRT 3030)
Comprehensive user guide for the Braun ThermoScan 3 Infrared Ear Thermometer (Model IRT 3030). This document provides detailed instructions on indications for use, product description, warnings, operating procedures, care and cleaning, troubleshooting, technical specifications, calibration, and warranty information.
Preview Braun ThermoScan 7 IRT6520 Ear Thermometer User Manual and Guide
Comprehensive guide for the Braun ThermoScan 7 IRT6520 ear thermometer, covering setup, usage, features like Age Precision™ technology, troubleshooting, and specifications.
Preview Braun ThermoScan 7 IRT 6520/IRT 6510: Infrared Ear Thermometer Guide
Learn how to use the Braun ThermoScan 7 infrared ear thermometer (IRT 6520/IRT 6510) with AgeSmart™ technology for accurate, age-adjustable fever guidance. Features, usage instructions, and fever interpretation.
Preview Braun ThermoScan IRT 3030: User Manual and Operating Guide
Comprehensive user manual for the Braun ThermoScan IRT 3030 infrared ear thermometer, covering product description, safety information, operating instructions, care, troubleshooting, and specifications. Learn how to accurately measure body temperature for all ages.
Preview Braun ThermoScan IRT6030/IRT6520 Infrared Ear Thermometer User Manual
Comprehensive user manual for the Braun ThermoScan IRT6030 and IRT6520 infrared ear thermometers. Learn about accurate temperature measurement, AgeSmart™ technology, ExacTemp™, safety, and maintenance for reliable health monitoring.