User Manual for PPI models including: LabCon Recording Printer Interface, LabCon, Recording Printer Interface, Printer Interface, Interface
Temperature control system | Temperature Recorders India - PPI controller
File Info : application/pdf, 1 Pages, 432.33KB
DocumentDocumentLabCon (Printer) Recording + Printer Interface Operation Manual This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net OPERATOR PAGE PARAMETERS Parameters Settings (Default Value) Select Print Option>> Time Start Command >> Time Abort Command >> Time Interval (H:M) >> None Print (New) Re-Print (Old) Print Info Page (Default : None) Yes No (Default : No) 0.00 to 500.00 (HH:MM) (Default : 0.10) Ctrl Set Value >> Setpoint LO limit to Setpoint HI limit (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 25.0) Ctrl Lo Deviation >> For RTD & DC Linear : 0.2 to 99.9 For Thermocouple : 2 to 99 (Default : 2.0) Ctrl Hi Deviation >> Change Password >> For RTD & DC Linear : 0.2 to 99.9 For Thermocouple : 2 to 99 (Default : 2.0) 1 to 100 (Default : 0) SUPERVISORY > SENSOR INPUT Parameters Settings (Default Value) Ctrl Zero Offset >> -50 to 50 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 0.0) SUPERVISORY > RECORDING Parameters Settings (Default Value) Rec. Interval (min) >> 0 to 250 Min (Default : 5 Min) Alarm Toggle Record >> Enable Disable (Default : Enable) Del Print Records >> Yes No (Default : No) Del Display Record >> RTC Time >> Yes No (Default : No) 0 to 23 for Hour 0 to 59 for Min (Default : NA) RTC Date >> 1 to 31 (Default : NA) RTC Month >> 1 to 12 (Default : NA) RTC Year >> 2000 to 2099 (Default : NA) SUPERVISORY > CONTROL Parameters Settings (Default Value) Tune >> Yes No (Default : No) Setpoint LO Limit >> Min Range for the Selected Input Type to Setpoint HI Limit (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 0.0) Setpoint HI Limit >> Setpoint LO Limit to Max Range for the Selected Input Type (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 600.0) Compressor Setpoint >> 0 to 100 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 45.0) Compressor Hyst >> 0.1 to 99.9 (Default : 2.0) Heat Ctrl Action >> Heat Hyst >> ON-OFF PID (Default : PID) 0.1 to 99.9 (Default : 0.2) Heat Only Control Heat + Cool Control Zone : Single Heat + Cool Control Zone : Dual Proportional Band >> Proportional Band >> PrCozpoPrrtioopnaBl aBnadnd>>for 0.1 to 999.9 0.1 to 999.9 Cool Pre-dominant zone (Default : 50.0) (Default : 50.0) 0.1 to 999.9 (Default : 50.0) Integral Time >> 0 to 3600 sec (Default : 100 sec) Derivative Time >> 0 to 600 sec (Default : 16 sec) Integral Time >> 0 to 3600 sec (Default : 100 sec) Derivative Time >> 0 to 600 sec (Default : 16 sec) CzInItnetgergarlaTlimTiemfeor>> Cool Pre-dominant zone 0 to 3600 sec (Default : 100 sec) Cz Derivative Time >> Derivative Time for Cool Pre-dominant zone 0 to 600 sec (Default : 16 sec) Cycle Time >> 0.5 to 100.0 sec (Default : 10.0 sec) Cycle Time >> 0.5 to 100.0 sec (Default : 10.0 sec) PrHozpoPrrtioopnaBl aBnadnd>>for Heat Pre-dominant zone 0.1 to 999.9 (Default : 50.0) Overshoot Inhibit >> Enable Disable Overshoot Inhibit >> Enable Disable HzInIntetgergarlaTlimTiemfeor>> Heat Pre-dominant zone (Default : Disable) (Default : Disable) 0 to 3600 sec (Default : 100 sec) Cutoff Factor >> 1.0 to 2.0 sec (Default : 1.2 sec) Cutoff Factor >> 1.0 to 2.0 sec (Default : 1.2 sec) Hz Derivative Time >> Derivative Time for Heat Pre-dominant zone 0 to 600 sec (Default : 16 sec) Cycle Time >> 0.5 to 100.0 sec (Default : 10.0 sec) Overshoot Inhibit >> Enable Disable (Default : Disable) FACTORY > CONTROL SENSOR INPUT Parameters Settings (Default Value) Input Type >> Refer Table 1 (Default : RTD Pt100) Signal LO >> Input Type Settings Default 0 to 20mA 0.00 to Signal High 0.00 4 to 20mA 4.00 to Signal High 4.00 0 to 5V 0.000 to Signal High 0.000 0 to 10V 0.00 to Signal High 0.00 1 to 5V 1.000 to Signal High 1.000 Signal HI >> Range LO >> Range HI >> Input Type Settings Default 0 to 20mA Signal Low to 20.00 20.00 4 to 20mA Signal Low to 20.00 20.00 0 to 5V Signal Low to 5.000 5.000 0 to 10V Signal Low to 10.00 10.00 1 to 5V Signal Low to 5.000 5.000 -199.9 to RANGE HI (Default : 0.0) RANGE LO to 999.9 (Default : 100.0) Cutoff Factor >> 1.0 to 2.0 sec (Default : 1.2 sec) FACTORY > ALARM PARAMETERS Parameters Settings (Default Value) SUPERVISORY > PRINTER SETTING Parameters Settings (Default Value) Line Per Page >> 25 to 100 (Default : 65) Hysteresis >> Inhibit >> 0.1 to 99.9 (Default : 0.2) Yes No (Default : Yes) Top Margine >> Bottom Margine >> Header & Footer >> Enable >> 1 to 5 (Default : 2) 1 to 5 (Default : 2) No On First Page Every Page (Default : No) Yes No (Default : No) SUPERVISORY > PRINT EVENT Parameters Settings (Default Value) Alarm Toggle >> RTC Modify >> Interval Modify >> Power Up >> Door Open >> Mains Fail >> Setpoint Modify >> Yes No (Default : Yes) SUPERVISORY > PASSWORD Parameters Settings (Default Value) Change Password >> 1000 to 1999 (Default : 123) FACTORY > HEAT COOL SELECT Parameters Settings (Default Value) Control Strategy >> Heat Only Cool Only Heat + Cool (Default : Heat + Cool) Control Strategy : Cool Only Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) Compressor Strategy >> Control Strategy : Heat + Cool CONT. OFF CONT. ON SP BASED PV BASED (Default : CONT. ON) CONT. ON Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) SP BASED Boundary Set Value >> 0 to 100 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 45.0) Control Zones >> Single Dual (Default : Single) Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) PV BASED Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) SUPERVISORY > EXIT Parameters Settings (Default Value) Exit Setup Mode >> Yes No (Default : No) FACTORY > SOAK TIMER PARAMETERS Parameters Settings (Default Value) Enable >> No Yes (Default : No) Start Band >> 0 to 999.9 (Default : 0.5) Holdback Strategy >> None Up Down Both (Default : None) Hold Band >> 0.1 to 999.9 (Default : 0.5) Heat Off >> No Yes (Default : No) Cool Off >> No Yes (Default : No) Power Recovery >> Abort Restart Continuous (Default : Restart) FACTORY > DOOR OPEN Parameters Settings (Default Value) Enable >> Yes No (Default : No) Switch Logic >> Door Alrm Dly (sec) >> Close : Door Open Open : Door Open (Default : Close : Door Open) 0 to 1000 Sec (Default : 60 Sec) FACTORY > MAINS FAILURE Parameters Settings (Default Value) Enable >> Yes No (Default : No) Switch Logic >> Close : Mains Fail Open : Mains Fail (Default : Close : Mains Fail) FACTORY > PASSWORD Parameters Settings (Default Value) Change Password >> 2000 to 2999 (Default : 321) FACTORY > FACTORY DEFAULT Parameters Settings (Default Value) Set To Default >> Yes No (Default : No) FACTORY > EXIT Parameters Settings (Default Value) Exit Setup Mode >> Yes No (Default : No) 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar - 401 210. Sales : 8208199048 / 8208141446 Support : 07498799226 / 08767395333 E: sales@ppiindia.net, support@ppiindia.net What it means Type J Thermocouple Type K Thermocouple Type T Thermocouple Type R Thermocouple Type S Thermocouple Type B Thermocouple Type N Thermocouple Reserve 3-wire, RTD Pt100 0 to 20mA DC current 4 to 20mA DC current 0 to 5.0V DC voltage 0 to 10.0V DC voltage 1 to 5.0V DC voltage TABLE 1 Range (Min. to Max.) Resolution 0 to +960°C -200 to +1376°C -200 to +385°C 0 to +1770°C 0 to +1765°C Fixed 1°C 0 to +1825°C 0 to +1300°C Reserved for customer specific Thermocouple type not listed above. The type shall be specified in accordance with the ordered (optional on request) Thermocouple type. -199.9 to 600.0°C Fixed 0.1°C -199.9 to 999.9 units Fixed 0.1 unit ELECTRICAL CONNECTIONS SOAK START ACK BATTERY 01 234 COMMON DOOR RS485 Control Outputs COMM HTR CMP ALM +DEV- +PC- + - + - + - 9 10 11 12 13 14 15 16 17 18 LabCon (w/o map) Configuration PC Printer Recording 5678 Pt100 +++mVA--- TC Supply 18~32VDC +- 19 20 21 PV ERROR INDICATIONS Message OPEN OVR UNR Error Type Sensor Open Over-range Under-range Cause Sensor (RTD Pt100) Broken / Open Temperature above Max. Specified Range Temperature below Min. Specified Range FRONT PANEL KEYS Symbol Key Scroll Alarm Acknowledge DOWN UP Function Press to scroll through various Process Information Screens in Normal Operation Mode. Press to acknowledge and mute (if active) alarm output. Press to decrease the parameter value. Pressing once decreases the value by one count; keeping pressed speeds up the change. Press to increase the parameter value. Pressing once increases the value by one count; keeping pressed speeds up the change. SET-UP ENTER Press to enter or exit set-up mode. Press to store the set parameter value and to scroll to the next parameter. Jan 2022